Experimental and numerical investigation of a cross flow air-to-water heat pipe-based heat exchanger used in waste heat recovery

Abstract This paper applies CFD modelling and numerical calculations to predict the thermal performance of a cross flow heat pipe based heat exchanger. The heat exchanger under study transfers heat from air to water and it is equipped with six water-charged wickless heat pipes, with a single-pass flow pattern on the air side (evaporator) and two flow passes on the water side (condenser). For the purpose of CFD modelling, the heat pipes were considered as solid devices of a known thermal conductivity which was estimated by experiments conducted on the exact same heat pipe configuration under an entire testing range. The CFD results were compared with the experimental and the numerical results and it was found that the modelling predictions are within 10% of the experimental results.

[1]  L. Schwartz Handbook Of Heat Transfer , 2016 .

[2]  van der Cwm Cees Geld,et al.  Air heat exchangers with long heat pipes: experiments and predictions , 2007 .

[3]  Yat Huang Yau,et al.  The use of a double heat pipe heat exchanger system for reducing energy consumption of treating ventilation air in an operating theatre—A full year energy consumption model simulation , 2008 .

[4]  F. Geoola,et al.  A design procedure for gravity-assisted heat pipe heat exchanger , 1984 .

[5]  Amir Faghri,et al.  Heat Pipe Science And Technology , 1995 .

[6]  Amir Faghri,et al.  HEAT PIPES: REVIEW, OPPORTUNITIES AND CHALLENGES , 2014 .

[7]  Reza Hosseini,et al.  Experimental investigation of effective parameters and correlation of geyser boiling in a two-phase closed thermosyphon , 2010 .

[8]  Amir Faghri,et al.  Thermal characteristics of a closed thermosyphon under various filling conditions , 2014 .

[9]  Hussam Jouhara,et al.  Experimental investigation of a thermosyphon based heat exchanger used in energy efficient air handling units , 2012 .

[10]  Martin Désilets,et al.  Optimization of an industrial heat exchanger using an open-source CFD code , 2014 .

[11]  A. Zukauskas Heat Transfer from Tubes in Crossflow , 1972 .

[12]  Hussam Jouhara,et al.  Experimental investigation of wraparound loop heat pipe heat exchanger used in energy efficient air handling units , 2010 .

[13]  Hao Peng,et al.  Numerical simulation and experimental verification on thermal performance of a novel fin-plate thermosyphon , 2012 .

[14]  Linjiang Zou,et al.  Study on the heat transfer characteristics of a moderate-temperature heat pipe heat exchanger , 2015 .

[15]  Amir Faghri,et al.  Review and Advances in Heat Pipe Science and Technology , 2012 .

[16]  P. Johnson,et al.  Design, construction and testing of a thermosyphon heat exchanger for medium temperature heat recovery in bakeries , 1995 .

[17]  Yat Huang Yau,et al.  A review on the application of horizontal heat pipe heat exchangers in air conditioning systems in the tropics , 2010 .

[18]  Masoud Rahimi,et al.  CFD modeling of flow and heat transfer in a thermosyphon , 2010 .

[19]  John Kaiser Calautit,et al.  Passive energy recovery from natural ventilation air streams , 2014 .

[20]  John Kaiser Calautit,et al.  Comparison between evaporative cooling and a heat pipe assisted thermal loop for a commercial wind tower in hot and dry climatic conditions , 2013 .

[21]  Hussam Jouhara,et al.  Heat pipe based thermal management systems for energy-efficient data centres , 2014 .

[22]  Yaxiong Wang,et al.  Experimental investigation of the thermal performance of a novel concentric condenser heat pipe array , 2015 .

[23]  Leonard L. Vasiliev,et al.  Heat pipes in modern heat exchangers , 2005 .

[24]  Hussam Jouhara,et al.  Experimental and numerical investigation of an air-to-water heat pipe-based heat exchanger , 2015 .

[25]  Gajanana C. Birur,et al.  NASA thermal control technologies for robotic spacecraft , 2003 .

[26]  W. Srimuang,et al.  A review of the applications of heat pipe heat exchangers for heat recovery , 2012 .

[27]  S. H. Noie Investigation of thermal performance of an air-to-air thermosyphon heat exchanger using ε-NTU method , 2006 .

[28]  Janusz T. Cieśliński,et al.  Heat transfer characteristics of a two-phase thermosyphon heat exchanger , 2013 .

[29]  Amélie Danlos,et al.  Some Efficient Solutions to Recover Low and Medium Waste Heat: Competitiveness of the Thermoacoustic Technology , 2014 .

[30]  Krishnaswamy Nandakumar,et al.  CFD simulation of bubbly two-phase flow in horizontal pipes , 2008 .

[31]  Teruo Sawada,et al.  Heat transfer performance of an inclined two-phase closed thermosyphon , 1983 .

[32]  Amir Faghri,et al.  Heat pipe heat exchangers and heat sinks: Opportunities, challenges, applications, analysis, and state of the art , 2015 .

[33]  W. Rohsenow A Method of Correlating Heat-Transfer Data for Surface Boiling of Liquids , 1952, Journal of Fluids Engineering.

[34]  M. Ahmadzadehtalatapeh,et al.  An air-conditioning system performance enhancement by using heat pipe based heat recovery technology , 2013 .

[35]  Jeehoon Choi,et al.  A new CPU cooler design based on an active cooling heatsink combined with heat pipes , 2012 .

[36]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[37]  S. H. Noie Heat transfer characteristics of a two-phase closed thermosyphon , 2005 .

[38]  Guiping Lin,et al.  Waste heat recovery using heat pipe heat exchanger for heating automobile using exhaust gas , 2003 .

[39]  Hussam Jouhara,et al.  Three-dimensional CFD simulation of Geyser boiling in a two-phase closed thermosyphon , 2016 .

[40]  M. Lele,et al.  Theoretical energy saving analysis of air conditioning system using heat pipe heat exchanger for Indian climatic zones , 2015 .

[41]  J. Danielewicz,et al.  Experimental and analytical performance investigation of air to air two phase closed thermosyphon based heat exchangers , 2014 .

[42]  Hussam Jouhara,et al.  Numerical modelling of the temperature distribution in a two-phase closed thermosyphon , 2013 .