Freeze clamping musculo-tendinous junctions for in vitro simulation of joint mechanics.

Incorporation of physiologic muscle tensions to simulate normal in vivo joint loading in cadaveric biomechanical studies has been a challenging problem, especially about the knee, foot, and shoulder. Simulation of muscle contraction requires attachment of tension producing devices to musculotendinous units. To this end, we modified the 'cryo-jaw' device, first described by Riemersma and Schamhardt (1982, J. Biomechanics 15, 619-620) to couple linear actuators to fresh cadaver tendons. These clamps were used in the simulation of 11 different muscles in laboratory investigations of shoulder, elbow, knee, and foot function. The clamps were able to transmit repetitively 3500 N of quadriceps force in eight knees and 2000 N of Achilles force in 11 feet. Overall success rate was 95%.

[1]  J. Pugh,et al.  Cortical pelvic strains with varying size hemiarthroplasty in vitro. , 1989, Journal of biomechanics.

[2]  N. Sharkey,et al.  Effects of partial patellectomy and reattachment of the patellar tendon on patellofemoral contact areas and pressures. , 1993, The Journal of bone and joint surgery. American volume.

[3]  H C Schamhardt,et al.  In vitro mechanical properties of equine tendons in relation to cross-sectional area and collagen content. , 1985, Research in veterinary science.

[4]  R. J. Pawluk,et al.  Quantitation of in situ contact areas at the glenohumeral joint: A biomechanical study , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  C. Dietschi,et al.  Mechanical function of subchondral bone as experimentally determined on the acetabulum of the human pelvis. , 1976, Journal of biomechanics.

[6]  G. Smidt Biomechanical analysis of knee flexion and extension. , 1973, Journal of biomechanics.

[7]  M. Panjabi,et al.  Spinal Stability and Intersegmental Muscle Forces: A Biomechanical Model , 1989, Spine.

[8]  H C Schamhardt,et al.  The cryo-jaw, a clamp designed for in vitro rheology studies of horse digital flexor tendons. , 1982, Journal of biomechanics.

[9]  I. Ringqvist,et al.  Knee extension. Measurement of the isometric force in different positions of the knee-joint. , 1969, Acta orthopaedica Scandinavica.

[10]  W. Hayes,et al.  Force ratios in the quadriceps tendon and ligamentum patellae , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  M. Nordin,et al.  Basic biomechanics of the skeletal system , 1980 .