Indoor thermal comfort characteristics under the control of a direct expansion air conditioning unit having a variable-speed compressor and a supply air fan

Indoor thermal environment is important as it affects the health and productivity of building occupants. Direct expansion (DX) air conditioning (A/C) units are commonly used for environmental control in small- to medium-scaled buildings. This paper reports on an experimental study to investigate the indoor thermal comfort characteristics under the control of a DX A/C unit having variable-speed compressor and supply fan at a fixed space cooling load but having three different ratios between its sensible part and latent part. The experimental results suggested that under a fixed indoor total cooling load with three different space sensible heat ratios (SHRs) of 0.92, 0.72 and 0.62, varying both speeds of compressor and supply fan in the DX A/C unit would influence indoor thermal comfort. Furthermore, when a DX A/C unit having variable-speed compressor and supply fan is used for indoor thermal comfort control under abnormal indoor load conditions, its ability of indoor thermal comfort control through varying compressor speed and supply fan speed may be duly restricted.

[1]  Anastasios I. Stamou,et al.  Evaluation of thermal comfort in galatsi arena of the olympics ?Athens 2004? using a CFD model , 2008 .

[2]  Zheng Li,et al.  An experimental study on the inherent operational characteristics of a direct expansion (DX) air conditioning (A/C) unit , 2007 .

[3]  K. Yang,et al.  AN APPROACH TO BUILDING ENERGY SAVINGS USING THE PMV INDEX , 1997 .

[4]  Zheng Li,et al.  The characteristics of space cooling load and indoor humidity control for residences in the subtropics , 2006 .

[5]  Nathan Mendes,et al.  Predictive controllers for thermal comfort optimization and energy savings , 2008 .

[6]  Ruxu Du,et al.  Design of intelligent comfort control system with human learning and minimum power control strategies , 2008 .

[7]  T. L. Jong,et al.  Thermal comfort control on multi-room fan coil unit system using LEE-based fuzzy logic , 2005 .

[8]  Liwei Tian,et al.  Field study on occupants’ thermal comfort and residential thermal environment in a hot-humid climate of China , 2007 .

[9]  K. I. Krakow,et al.  Analytical determination of PID coefficients for temperature and humidity control during cooling and dehumidifying by compressor and evaporator fan speed variation , 1995 .

[10]  Ardeshir Mahdavi,et al.  Integrating thermal comfort field data analysis in a case-based building simulation environment , 2001 .

[11]  Mohammad. Rasul,et al.  Thermal-comfort analysis and simulation for various low-energy cooling-technologies applied to an office building in a subtropical climate , 2008 .

[12]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .