3D pulse EPR imaging from sparse-view projections via constrained, total variation minimization.

Tumors and tumor portions with low oxygen concentrations (pO2) have been shown to be resistant to radiation therapy. As such, radiation therapy efficacy may be enhanced if delivered radiation dose is tailored based on the spatial distribution of pO2 within the tumor. A technique for accurate imaging of tumor oxygenation is critically important to guide radiation treatment that accounts for the effects of local pO2. Electron paramagnetic resonance imaging (EPRI) has been considered one of the leading methods for quantitatively imaging pO2 within tumors in vivo. However, current EPRI techniques require relatively long imaging times. Reducing the number of projection scan considerably reduce the imaging time. Conventional image reconstruction algorithms, such as filtered back projection (FBP), may produce severe artifacts in images reconstructed from sparse-view projections. This can lower the utility of these reconstructed images. In this work, an optimization based image reconstruction algorithm using constrained, total variation (TV) minimization, subject to data consistency, is developed and evaluated. The algorithm was evaluated using simulated phantom, physical phantom and pre-clinical EPRI data. The TV algorithm is compared with FBP using subjective and objective metrics. The results demonstrate the merits of the proposed reconstruction algorithm.

[1]  Colin Mailer,et al.  Absolute oxygen R1e imaging in vivo with pulse electron paramagnetic resonance , 2014, Magnetic resonance in medicine.

[2]  Emil Y. Sidky,et al.  Algorithm-Enabled Low-Dose Micro-CT Imaging , 2011, IEEE Transactions on Medical Imaging.

[3]  E. Somersalo,et al.  Statistical inverse problems: discretization, model reduction and inverse crimes , 2007 .

[4]  Xiao Han,et al.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT. , 2013, Physics in medicine and biology.

[5]  J S Petersson,et al.  EPR and DNP properties of certain novel single electron contrast agents intended for oximetric imaging. , 1998, Journal of magnetic resonance.

[6]  Howard J Halpern,et al.  Comparison of parabolic filtration methods for 3D filtered back projection in pulsed EPR imaging. , 2014, Journal of magnetic resonance.

[7]  Howard J Halpern,et al.  Principal component analysis enhances SNR for dynamic electron paramagnetic resonance oxygen imaging of cycling hypoxia in vivo , 2014, Magnetic resonance in medicine.

[8]  Hengyong Yu,et al.  A soft-threshold filtering approach for reconstruction from a limited number of projections , 2010, Physics in medicine and biology.

[9]  M. Vannier,et al.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction? , 2009, Inverse problems.

[10]  Emil Y. Sidky,et al.  Quantifying Admissible Undersampling for Sparsity-Exploiting Iterative Image Reconstruction in X-Ray CT , 2011, IEEE Transactions on Medical Imaging.

[11]  Xiao Han,et al.  Optimization-based reconstruction of sparse images from few-view projections , 2012, Physics in medicine and biology.

[12]  Rizwan Ahmad,et al.  Compressed sensing of spatial electron paramagnetic resonance imaging , 2014, Magnetic resonance in medicine.

[13]  Armand Wirgin,et al.  The inverse crime , 2004, math-ph/0401050.

[14]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[15]  Hengyong Yu,et al.  SART-Type Image Reconstruction from a Limited Number of Projections with the Sparsity Constraint , 2010, Int. J. Biomed. Imaging.

[16]  Howard J Halpern,et al.  Simulation of 4D spectral-spatial EPR images. , 2007, Journal of magnetic resonance.

[17]  D. L. Donoho,et al.  Compressed sensing , 2006, IEEE Trans. Inf. Theory.

[18]  Marc Teboulle,et al.  A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems , 2009, SIAM J. Imaging Sci..

[19]  Howard J Halpern,et al.  Spatially uniform sampling in 4-D EPR spectral-spatial imaging. , 2007, Journal of magnetic resonance.

[20]  E. Sidky,et al.  Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT , 2009, 0904.4495.

[21]  Colin Mailer,et al.  Spin echo spectroscopic electron paramagnetic resonance imaging , 2006, Magnetic resonance in medicine.

[22]  Colin Mailer,et al.  Comparison of 250 MHz electron spin echo and continuous wave oxygen EPR imaging methods for in vivo applications. , 2011, Medical physics.

[23]  R. Kress,et al.  Inverse Acoustic and Electromagnetic Scattering Theory , 1992 .

[24]  Xiaochuan Pan,et al.  Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy , 2015, Physics in medicine and biology.

[25]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[26]  Xiaochuan Pan,et al.  Image reconstruction from few views by non-convex optimization , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[27]  Shingo Matsumoto,et al.  Evaluation of partial k‐space strategies to speed up time‐domain EPR imaging , 2013, Magnetic resonance in medicine.

[28]  A. Averbuch,et al.  3D Fourier based discrete Radon transform , 2003 .

[29]  Franz Pfeiffer,et al.  An algebraic iterative reconstruction technique for differential X-ray phase-contrast computed tomography. , 2013, Zeitschrift fur medizinische Physik.

[30]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[31]  Xiaochuan Pan,et al.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT , 2010, Physics in medicine and biology.

[32]  Xiaochuan Pan,et al.  First-order convex feasibility algorithms for x-ray CT. , 2012, Medical physics.

[33]  Howard J Halpern,et al.  Electron paramagnetic resonance oxygen imaging of a rabbit tumor using localized spin probe delivery. , 2010, Medical physics.

[34]  E. Candès The restricted isometry property and its implications for compressed sensing , 2008 .

[35]  Howard J Halpern,et al.  Maximally spaced projection sequencing in electron paramagnetic resonance imaging. , 2015, Concepts in magnetic resonance. Part B, Magnetic resonance engineering.

[36]  R. Chartrand,et al.  Constrained \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}${\rm T}p{\rm V}$\end{document} Minimization for Enhance , 2014, IEEE journal of translational engineering in health and medicine.