The Effect of Sparger Geometry on Gas Bubble Flow Behaviors Using Electrical Resistance Tomography

Abstract By electrical resistance tomography (ERT) the cross sectional profiles of gas hold-up in a o56mm bubble column are obtained with four designs of gas sparger. The effect of sparger geometry on the bubble distribution is revealed by applying a sensitivity conjugated gradients reconstruction method (SCG). Experimental results show that overall hold-up obtained by ERT is generally in good agreement with those measured with the pressure transducer and the ERT system produces informative evidence that the radial profiles of hold-up is very similar to the sparger design in the lower section of bubble column. Meanwhile, the rise velocity of bubble swarm and the Sauter mean bubble size are evaluated using ERT based on dynamic gas disengagement theory. The experimental results are in good agreement with correlations and conventional estimation obtained using pressure transmitter methods.

[1]  Gary Lucas,et al.  Measurement of the solids volume fraction and velocity distributions in solids–liquid flows using dual-plane electrical resistance tomography , 1999 .

[2]  Mi Wang,et al.  ELECTRICAL RESISTANCE TOMOGRAPHIC SENSING SYSTEMS FOR INDUSTRIAL APPLICATIONS , 1999 .

[3]  U. Parasu Veera,et al.  Gamma ray tomography design for the measurement of hold-up profiles in two-phase bubble columns , 2001 .

[4]  Dominique Toye,et al.  Analysis of electrical resistance tomography measurements obtained on a bubble column , 2001 .

[5]  Zhang Tongwang APPLICATION OF PRESSURE TRANSDUCING TECHNOLOGY TO MEASUREMENT OF HYDRODYNAMICS IN BUBBLE COLUMN , 2004 .

[6]  Mi Wang,et al.  Inverse solutions for electrical impedance tomography based on conjugate gradients methods , 2002 .

[7]  Timothy J. O'Hern,et al.  Gamma-densitometry tomography of gas holdup spatial distribution in industrial-scale bubble columns , 1995 .

[8]  Dieter Mewes,et al.  Tomographic imaging of transient multiphase flow in bubble columns , 2000 .

[9]  Haibo Jin,et al.  Bubble Behavior of a Large-Scale Bubble Column with Elevated Pressure , 2004 .

[10]  Kiyomi Akita,et al.  Bubble Size, Interfacial Area, and Liquid-Phase Mass Transfer Coefficient in Bubble Columns , 1974 .

[11]  Mi Wang,et al.  Measurements of gas-liquid mixing in a stirred vessel using electrical resistance tomography (ERT) , 2000 .

[12]  Richard A Williams,et al.  Electrical tomography techniques for process engineering applications , 1995 .

[13]  Steven L. Ceccio,et al.  Validation of Electrical-Impedance Tomography for Measurements of Material Distribution in Two-Phase Flows , 2000 .

[14]  H. Haringa,et al.  MASS-TRANSFER AND BUBBLE-SIZE IN A BUBBLE-COLUMN UNDER PRESSURE , 1994 .

[15]  D. Mewes,et al.  Tomographic Measurement Techniques – Visualization of Multiphase Flows , 1998 .

[16]  Harvey D. Mendelson The prediction of bubble terminal velocities from wave theory , 1967 .

[17]  Robert W. Field,et al.  Bubble Column Reactors , 1991 .

[18]  Milorad P. Dudukovic,et al.  Opaque Multiphase Reactors: Experimentation, Modeling and Troubleshooting , 2000 .