ABSTRACT. Objective: To demonstrate a subdermal wire electrode technique for establishing a ground (GND) and reference (REF) during long-term EEG monitoring (LTM) with intracranial electrodes. Usually, a separate GND and REF are required and this GND&REF pair can be selected contacts in the invasive electrode arrays themselves, special invasive electrodes, or Standard surface disc electrodes which require frequent maintenance. We investigated the use of a pair of chronic Subdermal Wire Electrodes (SWE) for use as GND&REF. Methods: A pair of SWEs as GND&REF was tested in nine patients undergoing invasive EEG monitoring. SWE impedances were monitored in two patients and compared to disc electrode impedances. Results: Without maintenance, SWE impedances remained low and stable during the entire recording period (up to 20 days), whereas disc electrodes showed rapid impedance increase όfter the first day. In all nine patients, the consistent and durable integrity of the GND&REF pair of SWE allowed for a good quality EEG recording. No local skin complications were observed. Conclusions: A pair of SWE electrodes provides a GND&REF system that is easy to place, maintain, and provides a high quality recording with long-term stability when couplecl with referential based EEG recording system from invasive electrodes. Significance: A more efficient means of establishing a GND&REF pair during the monitoring of patients with invasive electrodes is described.
[1]
Stephen Perrig,et al.
Imaging Compatible Electrodes for Continuous Electroencephalogram Monitoring in the Intensive Care Unit
,
2009,
Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.
[2]
John R Ives,et al.
New Chronic EEG Electrode for Critical/Intensive Care Unit Monitoring
,
2005,
Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.
[3]
J R Ives,et al.
New sphenoidal electrode assembly to permit long-term monitoring of the patient's ictal or interictal EEG.
,
1977,
Electroencephalography and clinical neurophysiology.
[4]
Seyed M. Mirsattari,et al.
A comparison of subdermal wire electrodes with collodion-applied disk electrodes in long-term EEG recordings in ICU
,
2006,
Clinical Neurophysiology.
[5]
Mark Quigg,et al.
Sixty Day Continuous Use of Subdermal Wire Electrodes for EEG Monitoring During Treatment of Status Epilepticus
,
2009,
Neurocritical care.
[6]
P. Tallgren,et al.
Evaluation of commercially available electrodes and gels for recording of slow EEG potentials
,
2005,
Clinical Neurophysiology.
[7]
P. Gloor,et al.
Update: chronic sphenoidal electrodes.
,
1978,
Electroencephalography and clinical neurophysiology.