Study on Section Properties of Deckplates with Flat-Hat Stiffners

It is the buckling of the compression portions of the deckplate that govern its behaviour under wet concrete construction loading. The size and position of intermediate stiffeners in the compression flanges of thin-plate steel decks exert a strong influence on the dominant buckling mode of the flange. Test sections composed of high-strength steel were brake pressed with a variety of Flat-hat intermediate stiffeners in the compression flange forming a progression from small to large stiffeners. The ABAQUS program to determine the effectiveness of intermediate stiffeners in controlling buckling modes is undertaken. A series of specimens are loaded with simple beam. Various buckling wave forms prior to ultimate failure through a plastic collapse mechanism. The experimentally determined buckling stresses are found to be comparable with studies performed using the ABAQUS program analysis and using each country code.