T-wave offset localization from 8 vs. 15 lead dominant T wave

T-wave offset (Toff) identification may be jeopardized by the presence of noise and Toff-dispersion among leads. Use of the 15-lead (I, II, III, aVr, aVl, aVf, V1 to V6, X, Y, Z) dominant T wave (DTW15) proved to enhance Toff-identification reliability. However, since only 8 leads are independent, results could be biased by the data redundancy and the question arises as to whether the 8-independent-lead dominant T wave (DTW8) provides the same findings. The Daskalov and Christov's method for automatic Toff localization was applied to DTW8 and DTW15 of 46 control healthy subjects (CHS) and 103 acute myocardial infarction patients (AMIP). In both populations, Toff measurements were statistically equivalent (CHS: 340 vs. 340 ms; AMIP: 325 vs. 320 ms) and strongly correlated (CHS: 0.97; AMIP: 0.88). Thus, Toff identification from DTW15 is not significantly biased by the data redundancy and both DTW8 and DTW15 provide reliable Toff determination.

[1]  A. van Oosterom The dominant T wave and its significance. , 2003, Journal of cardiovascular electrophysiology.

[2]  P. Macfarlane,et al.  QT Interval and the Risk of Myocardial Infarction and All‐Cause Death: A Cohort Study , 2012, Cardiovascular Electrophysiology.

[3]  I. K. Daskalov,et al.  Automatic detection of the electrocardiogram T-wave end , 1999, Medical & Biological Engineering & Computing.

[4]  B. Darpo,et al.  Comparing Methods of Measurement for Detecting Drug‐Induced Changes in the QT Interval: Implications for Thoroughly Conducted ECG Studies , 2004, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[5]  P. Laguna,et al.  New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applications , 2006, Medical and Biological Engineering and Computing.

[6]  Yiyi Zhang,et al.  Electrocardiographic QT Interval and Mortality: A Meta-analysis , 2011, Epidemiology.

[7]  Paul Kligfield,et al.  Magnitude, Mechanism, and Reproducibility of QT Interval Differences Between Superimposed Global and Individual Lead ECG Complexes , 2007, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[8]  W. Zong,et al.  A QT interval detection algorithm based on ECG curve length transform , 2006, 2006 Computers in Cardiology.

[9]  Angela Agostinelli,et al.  Use of the dominant T wave to enhance reliability of T-wave offset identification. , 2014, Journal of electrocardiology.