Enhancing the Usability of Brain-Computer Interface Systems

Brain-computer interfaces (BCIs) aim to enable people to interact with the external world through an alternative, nonmuscular communication channel that uses brain signal responses to complete specific cognitive tasks. BCIs have been growing rapidly during the past few years, with most of the BCI research focusing on system performance, such as improving accuracy or information transfer rate. Despite these advances, BCI research and development is still in its infancy and requires further consideration to significantly affect human experience in most real-world environments. This paper reviews the most recent studies and findings about ergonomic issues in BCIs. We review dry electrodes that can be used to detect brain signals with high enough quality to apply in BCIs and discuss their advantages, disadvantages, and performance. Also, an overview is provided of the wide range of recent efforts to create new interface designs that do not induce fatigue or discomfort during everyday, long-term use. The basic principles of each technique are described, along with examples of current applications in BCI research. Finally, we demonstrate a user-friendly interface paradigm that uses dry capacitive electrodes that do not require any preparation procedure for EEG signal acquisition. We explore the capacitively measured steady-state visual evoked potential (SSVEP) response to an amplitude-modulated visual stimulus and the auditory steady-state response (ASSR) to an auditory stimulus modulated by familiar natural sounds to verify their availability for BCI. We report the first results of an online demonstration that adopted this ergonomic approach to evaluating BCI applications. We expect BCI to become a routine clinical, assistive, and commercial tool through advanced EEG monitoring techniques and innovative interface designs.

[1]  James J. S. Norton,et al.  Soft, curved electrode systems capable of integration on the auricle as a persistent brain–computer interface , 2015, Proceedings of the National Academy of Sciences.

[2]  S. Hillyard,et al.  Selective attention to stimulus location modulates the steady-state visual evoked potential. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[3]  Yong Gyu Lim,et al.  Conductive Polymer Foam Surface Improves the Performance of a Capacitive EEG Electrode , 2012, IEEE Transactions on Biomedical Engineering.

[4]  Fabio Babiloni,et al.  Passive BCI in Operational Environments: Insights, Recent Advances, and Future Trends , 2017, IEEE Transactions on Biomedical Engineering.

[5]  Tzyy-Ping Jung,et al.  Biosensor Technologies for Augmented Brain–Computer Interfaces in the Next Decades , 2012, Proceedings of the IEEE.

[6]  Chris Van Hoof,et al.  Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording , 2014, Sensors.

[7]  Yodchanan Wongsawat,et al.  Multi-command SSVEP-based BCI system via single flickering frequency half-field stimulation pattern , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  T. Jung,et al.  Using novel MEMS EEG sensors in detecting drowsiness application , 2006, 2006 IEEE Biomedical Circuits and Systems Conference.

[9]  Gary Garcia Molina,et al.  Spatial filters to detect steady-state visual evoked potentials elicited by high frequency stimulation: BCI application , 2010, Biomedizinische Technik. Biomedical engineering.

[10]  Sang-Hoon Lee,et al.  Self-Adhesive and Capacitive Carbon Nanotube-Based Electrode to Record Electroencephalograph Signals From the Hairy Scalp , 2016, IEEE Transactions on Biomedical Engineering.

[11]  J. Webster,et al.  Dry electrodes for electrocardiography , 2013, Physiological measurement.

[12]  N. Miki,et al.  Electroencephalogram measurement using polymer-based dry microneedle electrode , 2015, 2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS).

[13]  H. Flor,et al.  The thought translation device (TTD) for completely paralyzed patients. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[14]  Chang-Hwan Im,et al.  EEG-Based Brain-Computer Interfaces: A Thorough Literature Survey , 2013, Int. J. Hum. Comput. Interact..

[15]  L. Kirkup,et al.  A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.

[16]  Francisco J. Pelayo,et al.  Trends in EEG-BCI for daily-life: Requirements for artifact removal , 2017, Biomed. Signal Process. Control..

[17]  Gert Cauwenberghs,et al.  Ultra-High Input Impedance, Low Noise Integrated Amplifier for Noncontact Biopotential Sensing , 2011, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[18]  D J McFarland,et al.  BCI in practice. , 2016, Progress in brain research.

[19]  C. Grozea,et al.  Bristle-sensors—low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications , 2011, Journal of neural engineering.

[20]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[21]  Fabio Babiloni,et al.  The Dry Revolution: Evaluation of Three Different EEG Dry Electrode Types in Terms of Signal Spectral Features, Mental States Classification and Usability , 2019, Sensors.

[22]  Chin-Teng Lin,et al.  A Novel 16-Channel Wireless System for Electroencephalography Measurements With Dry Spring-Loaded Sensors , 2014, IEEE Transactions on Instrumentation and Measurement.

[23]  Raeed H. Chowdhury,et al.  Epidermal Electronics , 2011, Science.

[24]  Peter Enoksson,et al.  Micromachined electrodes for biopotential measurements , 2001 .

[25]  H. Flor,et al.  A spelling device for the paralysed , 1999, Nature.

[26]  Michael Tangermann,et al.  Natural stimuli improve auditory BCIs with respect to ergonomics and performance. , 2012, Journal of neural engineering.

[27]  B. Allison,et al.  BCI Demographics: How Many (and What Kinds of) People Can Use an SSVEP BCI? , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[28]  Alberto Prieto,et al.  An auditory brain–computer interface evoked by natural speech , 2012, Journal of neural engineering.

[29]  Kwang Suk Park,et al.  Reverse-curve-arch-shaped dry EEG electrode for increased skin–electrode contact area on hairy scalps , 2015 .

[30]  Brendan Z. Allison,et al.  Comparison of Dry and Gel Based Electrodes for P300 Brain–Computer Interfaces , 2012, Front. Neurosci..

[31]  J. Wolpaw,et al.  A P300-based brain–computer interface for people with amyotrophic lateral sclerosis , 2008, Clinical Neurophysiology.

[32]  Jeremy D. Slater,et al.  Quality assessment of electroencephalography obtained from a “dry electrode” system , 2012, Journal of Neuroscience Methods.

[33]  Ethan R. Buch,et al.  Think to Move: a Neuromagnetic Brain-Computer Interface (BCI) System for Chronic Stroke , 2008, Stroke.

[34]  T. Jung,et al.  Dry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces , 2012, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[35]  M S Treder,et al.  Decoding auditory attention to instruments in polyphonic music using single-trial EEG classification , 2014, Journal of neural engineering.

[36]  F Babiloni,et al.  Passive BCI beyond the lab: current trends and future directions , 2018, Physiological measurement.

[37]  A Graser,et al.  BCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI? , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[38]  Yonggang Huang,et al.  Multifunctional Epidermal Electronics Printed Directly Onto the Skin , 2013, Advanced materials.

[39]  G. R. Muller,et al.  Brain oscillations control hand orthosis in a tetraplegic , 2000, Neuroscience Letters.

[40]  Kwang Suk Park,et al.  An amplitude-modulated visual stimulation for reducing eye fatigue in SSVEP-based brain–computer interfaces , 2014, Clinical Neurophysiology.

[41]  F. Lacquaniti,et al.  From Spinal Central Pattern Generators to Cortical Network: Integrated BCI for Walking Rehabilitation , 2012, Neural plasticity.

[42]  E. Donchin,et al.  A P300-based brain–computer interface: Initial tests by ALS patients , 2006, Clinical Neurophysiology.

[43]  Teodiano Freire Bastos Filho,et al.  SSVEP-BCI implementation for 37–40 Hz frequency range , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[44]  Christoph S. Herrmann,et al.  Frequency-modulated steady-state visual evoked potentials: A new stimulation method for brain–computer interfaces , 2015, Journal of Neuroscience Methods.

[45]  Christian Kothe,et al.  Towards passive brain–computer interfaces: applying brain–computer interface technology to human–machine systems in general , 2011, Journal of neural engineering.

[46]  Bor-Shyh Lin,et al.  Novel Active Comb-Shaped Dry Electrode for EEG Measurement in Hairy Site , 2015, IEEE Transactions on Biomedical Engineering.

[47]  Chang-Hwan Im,et al.  Classification of selective attention to auditory stimuli: Toward vision-free brain–computer interfacing , 2011, Journal of Neuroscience Methods.

[48]  Yong Gyu Lim,et al.  Brain–computer interfaces using capacitive measurement of visual or auditory steady-state responses , 2013, Journal of neural engineering.

[49]  J. Luauté,et al.  BCI in patients with disorders of consciousness: clinical perspectives. , 2013, Annals of physical and rehabilitation medicine.

[50]  H. Zhang,et al.  A tensor-based scheme for stroke patients’ motor imagery EEG analysis in BCI-FES rehabilitation training , 2014, Journal of Neuroscience Methods.

[51]  G. Ruffinia,et al.  First human trials of a dry electrophysiology sensor using a carbon nanotube array interface , 2008 .

[52]  Gernot R. Müller-Putz,et al.  Self-Paced (Asynchronous) BCI Control of a Wheelchair in Virtual Environments: A Case Study with a Tetraplegic , 2007, Comput. Intell. Neurosci..

[53]  Andrzej Materka,et al.  Alternate half-field stimulation technique for SSVEP-based brain-computer interfaces , 2006 .

[54]  Cuntai Guan,et al.  Brain-Computer Interface in Stroke Rehabilitation , 2013, J. Comput. Sci. Eng..

[55]  Toshihiro Kawase,et al.  Use of high-frequency visual stimuli above the critical flicker frequency in a SSVEP-based BMI , 2015, Clinical Neurophysiology.

[56]  Hyun Jae Baek,et al.  Music and natural sounds in an auditory steady-state response based brain-computer interface to increase user acceptance , 2017, Comput. Biol. Medicine.

[57]  Xiaorong Gao,et al.  A half-field stimulation pattern for SSVEP-based brain-computer interface , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.