An Empirical Validation of Modeling Solar Gains Through a Glazing Unit Using Building Energy Simulation Programs

Empirical validation of building energy simulation tools is an important component in assessing the reliability of the simulation software. An experiment performed in conjunction with the International Energy Agency's Task 34/Annex 43 was used to assess the performance of four building energy simulation codes used to model an outdoor test cell with a glazing unit. The experiment was run for a 20-day period during October 2004, and experimental cooling powers were compared with predictions from (1) EnergyPlus, (2) DOE-2.1E, (3) TRNSYS-TUD, and (4) ESP-r. Detailed code inputs for optical and thermophysical properties as well as the impact of thermal bridges were quantified through experiments and simulations; numerous statistical parameters and sensitivity analyses were implemented to facilitate a thorough comparison of predicted and experimental cooling powers. The mean percentage differences for all four codes were: 1.9% for EnergyPlus, −3.6% for DOE-2.1E, −6.2% for TRNSYS-TUD, and 3.1% for ESP-r. The implications of various modeling procedures as well as a detailed discussion of the results are provided, specifically concerning the sensitivity of the code cooling power predictions to the selection of convective heat transfer coefficients and algorithms.

[1]  George N Walton,et al.  Thermal Analysis Research Program reference manual , 1983 .

[2]  P. Wouters,et al.  The use of outdoor test cells for thermal and solar building research within the PASSYS project , 1993 .

[3]  Søren Østergaard Jensen,et al.  Validation of building energy simulation programs: a methodology , 1995 .

[4]  Frederick C. Winkelmann,et al.  Modeling Windows in EnergyPlus , 2001 .

[5]  Th. Frank,et al.  Thermal simulation of buildings with double-skin façades , 2005 .

[6]  A. Roos,et al.  Evaluation of predictive models for the angle-dependent total solar energy transmittance of glazing materials , 2001 .

[7]  Refrigerating 2001 ASHRAE handbook : fundamentals , 2001 .

[8]  D. Arasteh,et al.  Modeling windows in DOE-2.1E , 1995 .

[9]  Geoffrey P. Hammond,et al.  Improved data correlations for buoyancy-driven convection in rooms , 1983 .

[10]  Paul Strachan,et al.  Series of experiments for empirical validation of solar gain modeling in building energy simulation codes—Experimental setup, test cell characterization, specifications and uncertainty analysis , 2006 .

[11]  Charles Anderson,et al.  Angular-dependent optical properties of low-e and solar control windows—: Simulations versus measurements , 2001 .

[12]  R. D. Judkoff,et al.  Validation of building energy analysis simulation programs at the solar energy research institute , 1988 .

[13]  R. Furler Angular Dependence of Optical Properties of Homogeneous Glasses , 1991 .

[14]  Gregory M. Maxwell,et al.  Daylighting - HVAC Interaction Tests for the Empirical Validation of Building Energy Analysis , 2003 .

[15]  H. Manz,et al.  Empirical validation of models to compute solar irradiance on inclined surfaces for building energy simulation , 2007 .

[16]  P. Strachan,et al.  Model validation using the PASSYS Test cells , 1993 .

[17]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[18]  M. Rubin,et al.  Models for the angle-dependent optical properties of coated glazing materials , 1999 .

[19]  J. Michalsky,et al.  Modeling daylight availability and irradiance components from direct and global irradiance , 1990 .

[20]  Taylor Francis Online HVAC & R research , 1995 .

[21]  Kevin J. Lomas,et al.  Empirical validation of building energy simulation programs , 1997 .