Non-destructive electrochemical techniques applied to the corrosion evaluation of the liner structures in nuclear power plants

The liner structure in nuclear power plants provides containment for the operation and therefore the study of its durability and integrity during its service life is an important issue. There are several causes for the deterioration of the liner, which in general involve corrosion due to its metallic nature. The present paper is aimed at describing the assessment of corrosion problems of two liners from two different nuclear power plants, which were evaluated using non-destructive electrochemical techniques. In spite of the testing difficulties arisen, from the results extracted it can be concluded that the electrochemical techniques applied are adequate for the corrosion evaluation. They provide important information about the integrity of the structure and allow for its evolution with time to be assessed.

[1]  C. Andrade,et al.  Quantitative measurements of corrosion rate of reinforcing steels embedded in concrete using polarization resistance measurements , 1978 .

[2]  Cruz Alonso,et al.  Comparison of rates of general corrosion and maximum pitting penetration on concrete embedded steel reinforcement , 1995 .

[3]  J. M. Doyle,et al.  SOME STRUCTURAL CONSIDERATIONS IN THE DESIGN OF NUCLEAR CONTAINMENT LINERS. , 1971 .

[4]  François Fleury,et al.  Containment Evaluation under Severe Accidents (CESA): synthesis of the predictive calculations and analysis of the first experimental results obtained on the Civaux mock-up , 2001 .

[5]  M. Stern,et al.  Electrochemical Polarization I . A Theoretical Analysis of the Shape of Polarization Curves , 1957 .

[6]  C. Andrade,et al.  Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types , 1988 .

[7]  Marta Castellote,et al.  Some principles of service life calculation of reinforcements and in situ corrosion monitoring by sensors in the radioactive waste containers of El Cabril disposal (Spain) , 2006 .

[8]  H. S. Kushwaha,et al.  Predictions of ultimate load capacity for pre-stressed concrete containment vessel model with BARC finite element code ULCA , 2003 .

[9]  C. Andrade,et al.  A new method forin-situ measurement of electrical resistivity of reinforced concrete , 1996 .

[10]  C. Andrade,et al.  Calibration by gravimetric losses of electrochemical corrosion rate measurement using modulated confinement of the current , 2005 .

[11]  Bruce R. Ellingwood,et al.  Methods for assessing NPP containment pressure boundary integrity , 2004 .

[12]  M. Pourbaix Atlas of Electrochemical Equilibria in Aqueous Solutions , 1974 .

[13]  J. Fullea,et al.  Nuevas técnicas avanzadas para la medida in situ de la corrosión en hormigón armado , 2001 .

[14]  J. Newman Resistance for Flow of Current to a Disk , 1966 .

[15]  O. Olowokere Failure of stiffened steel liners for nuclear reactor containment structures under construction , 1984 .