Multiblock PLS as an approach to compare and combine NIR and MIR spectra in calibrations of soybean flour

Abstract The present work is aimed at investigating the potential benefits of simultaneously combining near-infrared (NIR) and mid-infrared (MIR) spectral regions for use in calibration development of soybean flour quality properties (crude protein and moisture). NIR and MIR spectra were analysed separately using single partial least squares (PLS), and then both spectral data sets were utilized together in the modelling by applying two multiblock methodologies based on PLS regression: Multiblock PLS (MB-PLS) and Serial PLS (S-PLS). Utilizing the concept of net analyte signal (NAS), models constructed from NIR or MIR data were compared in terms of analytical figures of merit (sensitivity (SEN), selectivity (SEL) and limit of detection (LOD)). When utilized alone, the MIR spectra gave models with considerably inferior prediction power and analytical figures of merit than NIR-based models. The multiblock methodology revealed to be very useful, since it helped to determine if there was distinctive information in each spectral data set and evaluate the relative importance of each data set. The results pointed out the existence of additional information in the MIR spectra not present in the NIR spectra. Although several works have already been reported comparing NIR and MIR spectroscopic techniques using different multivariate regression techniques, at the best of our knowledge none of them applied the approach of multiblock PLS. Therefore, the present work intends to explore this direction, using the NIR and MIR spectra as predictor blocks to model flour's properties in a parallel mode (MB-PLS) or in a serial mode (S-PLS).

[1]  F. X. Rius,et al.  MULTIVARIATE DETECTION LIMITS ESTIMATORS , 1996 .

[2]  Herman Wold,et al.  Soft modelling: The Basic Design and Some Extensions , 1982 .

[3]  Tom Fearn,et al.  Practical Nir Spectroscopy With Applications in Food and Beverage Analysis , 1993 .

[4]  Bruce R. Kowalski,et al.  Partial least-squares path modelling with latent variables , 1979 .

[5]  John M. Chalmers Spectroscopy in process analysis , 2000 .

[6]  B. Kowalski,et al.  Theory of analytical chemistry , 1994 .

[7]  P. Williams,et al.  Near-Infrared Technology in the Agricultural and Food Industries , 1987 .

[8]  Avraham Lorber,et al.  Net analyte signal calculation in multivariate calibration , 1997 .

[9]  S. Delwiche,et al.  Determination of Protein in Ground Wheat Samples by Mid-Infrared Diffuse Reflectance Spectroscopy , 1997 .

[10]  L. E. Wangen,et al.  A multiblock partial least squares algorithm for investigating complex chemical systems , 1989 .

[11]  Svante Wold,et al.  Hierarchical multiblock PLS and PC models for easier model interpretation and as an alternative to variable selection , 1996 .

[12]  Anders Berglund,et al.  A serial extension of multiblock PLS , 1999 .

[13]  Nicolaas M. Faber,et al.  Net analyte signal calculation for multivariate calibration , 2003 .

[14]  P. Geladi Notes on the history and nature of partial least squares (PLS) modelling , 1988 .

[15]  J. Reeves Near- versus Mid-Infrared Diffuse Reflectance Spectroscopy for the Quantitative Determination of the Composition of Forages and By-Products , 1994 .

[16]  Herman Wold,et al.  Systems under indirect observation : causality, structure, prediction , 1982 .

[17]  Avraham Lorber,et al.  Analytical figures of merit for tensorial calibration , 1997 .

[18]  J. Westerhuis,et al.  Multivariate modelling of the pharmaceutical two‐step process of wet granulation and tableting with multiblock partial least squares , 1997 .

[19]  João A. Lopes,et al.  Modelling and identification of individual stage contributions in an industrial pharmaceutical process by multiblock PLS , 2004 .

[20]  J. Macgregor,et al.  Analysis of multiblock and hierarchical PCA and PLS models , 1998 .

[21]  A. Smilde,et al.  Multiblock PLS analysis of an industrial pharmaceutical process , 2002, Biotechnology and bioengineering.

[22]  John F. MacGregor,et al.  Process monitoring and diagnosis by multiblock PLS methods , 1994 .

[23]  F. Xavier Rius,et al.  Improved calculation of the net analyte signal in inverse multivariate calibration , 2001 .

[24]  A. Lorber Error propagation and figures of merit for quantification by solving matrix equations , 1986 .