Bioanalysis of recombinant proteins and antibodies by mass spectrometry.

In recent years, biotechnologically-derived drugs have been a major focus of research and development in the pharmaceutical industry. Their pharmacokinetics and pharmacokinetic/pharmacodynamic relationships impact every stage of the development process and require their assessment in the circulation in preclinical species and in humans. To this end, immunoassays are a reference, but standardisation remains an issue owing to the restricted pattern of antibody specificity and interference with endogenous components. As an alternative, we report here analytical strategies involving liquid chromatography coupled to mass spectrometry (LC-MS) for the accurate quantification of therapeutic proteins and antibodies in biological fluids.

[1]  S. Kern,et al.  Quality control of serum albumin depletion for proteomic analysis. , 2007, Clinical chemistry.

[2]  Darryl B. Hardie,et al.  Mass spectrometric quantitation of peptides and proteins using Stable Isotope Standards and Capture by Anti-Peptide Antibodies (SISCAPA). , 2004, Journal of proteome research.

[3]  J. M. Beals,et al.  In vivo deamidation characterization of monoclonal antibody by LC/MS/MS. , 2005, Analytical chemistry.

[4]  C. G. Edmonds,et al.  Tandem mass spectrometry of very large molecules. 2. Dissociation of multiply charged proline-containing proteins from electrospray ionization. , 1993, Analytical chemistry.

[5]  Viswanath Devanarayan,et al.  Recommendations on risk-based strategies for detection and characterization of antibodies against biotechnology products. , 2008, Journal of immunological methods.

[6]  C. Massart,et al.  Intermethod variability in TSH-receptor antibody measurement: implication for the diagnosis of Graves disease and for the follow-up of Graves ophthalmopathy. , 2009, Clinical chemistry.

[7]  Eric M Gage,et al.  Method development for the concentration determination of a protein in human plasma utilizing 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometric detection. , 2003, Rapid communications in mass spectrometry : RCM.

[8]  S. Gygi,et al.  Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[9]  M. Berna,et al.  Coupling immunoaffinity techniques with MS for quantitative analysis of low-abundance protein biomarkers , 2007, Expert review of proteomics.

[10]  E. Varesio,et al.  Ultra-fast quantitation of saquinavir in human plasma by matrix-assisted laser desorption/ionization and selected reaction monitoring mode detection. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[11]  John Mark Carter,et al.  Mass spectrometric detection of attomole amounts of the prion protein by nanoLC/MS/MS , 2007, Journal of the American Society for Mass Spectrometry.

[12]  April S Y Wong,et al.  Doping control analysis of insulin and its analogues in equine urine by liquid chromatography-tandem mass spectrometry. , 2008, Journal of chromatography. A.

[13]  R. Hansen,et al.  Antibody pharmacokinetics and pharmacodynamics. , 2004, Journal of pharmaceutical sciences.

[14]  K. Duffin,et al.  Online immunoaffinity liquid chromatography/tandem mass spectrometry determination of a type II collagen peptide biomarker in rat urine: Investigation of the impact of collision-induced dissociation fluctuation on peptide quantitation. , 2006, Analytical biochemistry.

[15]  R. Nelson,et al.  Quantitative mass spectrometric immunoassay of insulin like growth factor 1. , 2004, Journal of proteome research.

[16]  Elucidation of peptide metabolism by on-line immunoaffinity liquid chromatography mass spectrometry. , 2000, Rapid communications in mass spectrometry : RCM.

[17]  M. Stahl,et al.  Selective quantitative bioanalysis of proteins in biological fluids by on-line immunoaffinity chromatography-protein digestion-liquid chromatography-mass spectrometry. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[18]  E. De Pauw,et al.  Development of an absolute quantification method targeting growth hormone biomarkers using liquid chromatography coupled to isotope dilution mass spectrometry. , 2007, Journal of chromatography. A.

[19]  S. Swanson,et al.  Detection of neutralizing anti-therapeutic protein antibodies in serum or plasma samples containing high levels of the therapeutic protein. , 2006, Journal of immunological methods.

[20]  J. Tabet,et al.  Approach to the determination of insulin-like-growth-factor-I (IGF-I) concentration in plasma by high-performance liquid chromatography-ion trap mass spectrometry: use of a deconvolution algorithm for the quantification of multiprotonated molecules in electrospray ionization. , 2001, The Analyst.

[21]  R. Nelson,et al.  Novel mass spectrometric immunoassays for the rapid structural characterization of plasma apolipoproteins Published, JLR Papers in Press, December 1, 2002. DOI 10.1194/jlr.D200034-JLR200 , 2003, Journal of Lipid Research.

[22]  Werner Zolg,et al.  Quantification of C‐reactive protein in the serum of patients with rheumatoid arthritis using multiple reaction monitoring mass spectrometry and 13C‐labeled peptide standards , 2004, Proteomics.

[23]  B. Güttler,et al.  Protein quantification by isotope dilution mass spectrometry of proteolytic fragments: cleavage rate and accuracy. , 2008, Analytical chemistry.

[24]  H. R. Bergen,et al.  On-line immunoaffinity-liquid chromatography-mass spectrometry for identification of amyloid disease markers in biological fluids. , 2003, Analytical chemistry.

[25]  G. Doncel,et al.  Biological and Technical Variables Affecting Immunoassay Recovery of Cytokines from Human Serum and Simulated Vaginal Fluid: A Multicenter Study , 2008, Analytical chemistry.

[26]  K. Parker,et al.  Multiplexed Protein Quantitation in Saccharomyces cerevisiae Using Amine-reactive Isobaric Tagging Reagents*S , 2004, Molecular & Cellular Proteomics.

[27]  Darrell Ricke,et al.  Absolute quantification of monoclonal antibodies in biofluids by liquid chromatography-tandem mass spectrometry. , 2008, Analytical chemistry.

[28]  Tom Fiers,et al.  Pilot study for the standardization of insulin immunoassays with isotope dilution liquid chromatography/tandem mass spectrometry. , 2007, Clinical Chemistry.

[29]  Mark Brönstrup,et al.  Absolute quantification strategies in proteomics based on mass spectrometry , 2004, Expert review of proteomics.

[30]  C. Enjalbal,et al.  New example of proline-induced fragmentation in electrospray ionization mass spectrometry of peptides. , 2002, Rapid communications in mass spectrometry : RCM.

[31]  R. Sapin Insulin immunoassays: fast approaching 50 years of existence and still calling for standardization. , 2007, Clinical chemistry.

[32]  Eugen Koren,et al.  An acid dissociation bridging ELISA for detection of antibodies directed against therapeutic proteins in the presence of antigen. , 2005, Journal of immunological methods.

[33]  M. Maurel,et al.  Evaluation of a peptide ELISA for the detection of rituximab in serum. , 2007, Journal of immunological methods.

[34]  G. Nakamura,et al.  Binding Protein-3-Selective Insulin-Like Growth Factor I Variants: Engineering, Biodistributions, and Clearance. , 2001, Endocrinology.

[35]  O. Nemirovskiy,et al.  Immunoaffinity liquid chromatography-tandem mass spectrometry detection of nitrotyrosine in biological fluids: development of a clinically translatable biomarker. , 2008, Analytical biochemistry.

[36]  W Greg Miller,et al.  Standardization of insulin immunoassays: report of the American Diabetes Association Workgroup. , 2007, Clinical chemistry.

[37]  Jérôme Garin,et al.  Protein Standard Absolute Quantification (PSAQ) for improved investigation of staphylococcal food poisoning outbreaks , 2008, Proteomics.

[38]  Jeffrey R. Whiteaker,et al.  Antibody-based enrichment of peptides on magnetic beads for mass-spectrometry-based quantification of serum biomarkers. , 2007, Analytical biochemistry.

[39]  Douglas A Jeffery,et al.  "Product ion monitoring" assay for prostate-specific antigen in serum using a linear ion-trap. , 2008, Journal of proteome research.

[40]  M. Navarro,et al.  Variations observed for insulin concentrations in an interlaboratory quality control program may be due to interferences between reagents and the matrix of the control materials. , 2007, Clinical biochemistry.

[41]  Wilhelm Schänzer,et al.  Insulins in equine urine: qualitative analysis by immunoaffinity purification and liquid chromatography/tandem mass spectrometry for doping control purposes in horse-racing. , 2008, Rapid communications in mass spectrometry : RCM.

[42]  F. Vandenesch,et al.  Isotope-labeled Protein Standards , 2007, Molecular & Cellular Proteomics.

[43]  Shujia Dai,et al.  Quantification of sifuvirtide in monkey plasma by an on-line solid-phase extraction procedure combined with liquid chromatography/electrospray ionization tandem mass spectrometry. , 2005, Rapid communications in mass spectrometry : RCM.

[44]  D. Hochstrasser,et al.  Relative quantification of proteins in human cerebrospinal fluids by MS/MS using 6-plex isobaric tags. , 2008, Analytical chemistry.

[45]  Wilhelm Schänzer,et al.  Qualitative determination of synthetic analogues of insulin in human plasma by immunoaffinity purification and liquid chromatography-tandem mass spectrometry for doping control purposes. , 2005, Analytical chemistry.

[46]  M. Preece,et al.  Pharmacokinetic studies of recombinant human insulin-like growth factor I (rhIGF-I)/rhIGF-binding protein-3 complex administered to patients with growth hormone insensitivity syndrome. , 2006, The Journal of clinical endocrinology and metabolism.

[47]  E. Ezan,et al.  Immunopurification and mass spectrometric quantification of the active form of a chimeric therapeutic antibody in human serum. , 2008, Analytical chemistry.

[48]  Eric M Gage,et al.  A strategy of plasma protein quantitation by selective reaction monitoring of an intact protein. , 2003, Analytical chemistry.

[49]  R. Nelson,et al.  Development of recombinant-based mass spectrometric immunoassay with application to resistin expression profiling. , 2006, Analytical chemistry.

[50]  V. Mayya,et al.  Proteomic applications of protein quantification by isotope-dilution mass spectrometry , 2006, Expert review of proteomics.

[51]  E. Ezan,et al.  Quantification of small therapeutic proteins in plasma by liquid chromatography-tandem mass spectrometry: application to an elastase inhibitor EPI-hNE4. , 2006, Analytical chemistry.

[52]  Andrew N Hoofnagle,et al.  Quantification of thyroglobulin, a low-abundance serum protein, by immunoaffinity peptide enrichment and tandem mass spectrometry. , 2008, Clinical chemistry.

[53]  John C. Morris,et al.  Comparison of thyrotropin-receptor antibodies measured by four commercially available methods with a bioassay that uses Fisher rat thyroid cells. , 2003, Clinical chemistry.

[54]  M. Thevis,et al.  Determination of Synacthen in human plasma using immunoaffinity purification and liquid chromatography/tandem mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.

[55]  M. Quaglia,et al.  Amine-reactive isobaric tagging reagents: requirements for absolute quantification of proteins and peptides. , 2008, Analytical biochemistry.

[56]  Jos H Beijnen,et al.  Quantitative bioanalysis of peptides by liquid chromatography coupled to (tandem) mass spectrometry. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[57]  R. Humerickhouse,et al.  Investigation of the immunogenicity of a protein drug using equilibrium dialysis and liquid chromatography tandem mass spectrometry detection. , 2005, Analytical chemistry.

[58]  Olivier Heudi,et al.  Towards absolute quantification of therapeutic monoclonal antibody in serum by LC-MS/MS using isotope-labeled antibody standard and protein cleavage isotope dilution mass spectrometry. , 2008, Analytical chemistry.

[59]  Hendrik Neubert,et al.  Assessing immunogenicity in the presence of excess protein therapeutic using immunoprecipitation and quantitative mass spectrometry. , 2008, Analytical chemistry.

[60]  M. Thevis,et al.  Quantification of human insulin-like growth factor-1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionisation tandem mass spectrometry. , 2008, Rapid communications in mass spectrometry : RCM.

[61]  Xinping Fang,et al.  LC-MS/MS approach for quantification of therapeutic proteins in plasma using a protein internal standard and 2D-solid-phase extraction cleanup. , 2007, Analytical chemistry.

[62]  T. Hoffmann,et al.  Immunoprecipitation and liquid chromatographic-mass spectrometric determination of the peptide glucose-dependent insulinotropic polypeptides GIP1-42 and GIP3-42 from human plasma samples. New sensitive method to analyze physiological concentrations of peptide hormones. , 2001, Journal of chromatography. A.

[63]  J. Hale,et al.  Strategic use of immunoprecipitation and LC/MS/MS for trace-level protein quantification: myosin light chain 1, a biomarker of cardiac necrosis. , 2007, Analytical chemistry.

[64]  G. Nicol,et al.  Use of an Immunoaffinity-Mass Spectrometry-based Approach for the Quantification of Protein Biomarkers from Serum Samples of Lung Cancer Patients* , 2008, Molecular & Cellular Proteomics.

[65]  Jeffrey R. Whiteaker,et al.  Head-to-head comparison of serum fractionation techniques. , 2007, Journal of proteome research.

[66]  N. Kitteringham,et al.  Multiple reaction monitoring for quantitative biomarker analysis in proteomics and metabolomics. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[67]  J. Koziol,et al.  A critical evaluation of enzyme immunoassay kits for detection of antinuclear autoantibodies of defined specificities. III. Comparative performance characteristics of academic and manufacturers' laboratories. , 2003, The Journal of rheumatology.

[68]  J. Lee,et al.  Bioanalytical method development and validation for a large peptide HIV fusion inhibitor (Enfuvirtide, T-20) and its metabolite in human plasma using LC-MS/MS. , 2005, Journal of pharmaceutical and biomedical analysis.

[69]  Leigh Anderson,et al.  Quantitative Mass Spectrometric Multiple Reaction Monitoring Assays for Major Plasma Proteins* , 2006, Molecular & Cellular Proteomics.

[70]  S. Gandy,et al.  The profile of soluble amyloid beta protein in cultured cell media. Detection and quantification of amyloid beta protein and variants by immunoprecipitation-mass spectrometry. , 1996, The Journal of biological chemistry.

[71]  S. Carr,et al.  Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution*S , 2007, Molecular & Cellular Proteomics.

[72]  E. Birks,et al.  LC−MS/MS Method for Confirmation of Recombinant Human Erythropoietin and Darbepoetin α in Equine Plasma , 2007 .

[73]  Stacy Lawrence Biotech drug market steadily expands , 2005, Nature Biotechnology.

[74]  E. Ezan,et al.  Immuno-mass spectrometry assay of EPI-HNE4, a recombinant protein inhibitor of human elastase. , 2007, Rapid communications in mass spectrometry : RCM.

[75]  D. Holtzman,et al.  Quantitative analysis of amyloid beta peptides in cerebrospinal fluid of Alzheimer's disease patients by immunoaffinity purification and stable isotope dilution liquid chromatography/negative electrospray ionization tandem mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.

[76]  E. Birks,et al.  Differentiation and identification of recombinant human erythropoietin and darbepoetin Alfa in equine plasma by LC-MS/MS for doping control. , 2008, Analytical chemistry.

[77]  J. Banoub,et al.  Absolute quantification of Atlantic salmon and rainbow trout vitellogenin by the 'signature peptide' approach using electrospray ionization QqToF tandem mass spectrometry. , 2006, Journal of mass spectrometry : JMS.

[78]  Binodh DeSilva,et al.  Recommendations for the Bioanalytical Method Validation of Ligand-Binding Assays to Support Pharmacokinetic Assessments of Macromolecules , 2003, Pharmaceutical Research.

[79]  B. Davis,et al.  LC-MS/MS Quantification of Zn-α2 Glycoprotein: A Potential Serum Biomarker for Prostate Cancer , 2007 .

[80]  B. Meibohm,et al.  Pharmacokinetic aspects of biotechnology products. , 2004, Journal of pharmaceutical sciences.

[81]  R. Jansen,et al.  Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis. , 2006, Journal of chromatography. A.

[82]  P. Solter,et al.  Quantification of NTproBNP in rat serum using immunoprecipitation and LC/MS/MS: a biomarker of drug-induced cardiac hypertrophy. , 2008, Analytical chemistry.

[83]  R. Aebersold,et al.  Selected reaction monitoring for quantitative proteomics: a tutorial , 2008, Molecular systems biology.

[84]  W. Burkitt,et al.  Toward Système International d'Unité-traceable protein quantification: from amino acids to proteins. , 2008, Analytical biochemistry.

[85]  Gary Walsh,et al.  Post-translational modifications in the context of therapeutic proteins , 2006, Nature Biotechnology.