Practice Standards for Transcranial Doppler Ultrasound: Part I—Test Performance

Indications for the clinical use of transcranial Doppler (TCD) continue to expand while scanning protocols and quality of reporting vary between institutions. Based on literature analysis and extensive personal experience, an international expert panel started the development of guidelines for TCD performance, interpretation, and competence. The first part describes complete diagnostic spectral TCD examination for patients with cerebrovascular diseases. Cranial temporal bone windows are used for the detection of the middle cerebral arteries (MCA), anterior cerebral arteries (ACA), posterior cerebral arteries (PCA), C1 segment of the internal carotid arteries (ICA), and collateralization of flow via the anterior (AComA) and posterior (PComA) communicating arteries; orbital windows—for the ophthalmic artery (OA) and ICA siphon; the foraminal window—for the terminal vertebral (VA) and basilar (BA) arteries. Although there is a significant individual variability of the circle of Willis with and without disease, the complete diagnostic TCD examination should include bilateral assessment of the M2 (arbitrarily located at 30‐40 mm depth), M1 (40‐65 mm) MCA [with M1 MCA mid‐point at 50 mm (range 45‐55 mm), average length 16 mm (range 5‐24 mm), A1 ACA (60‐75 mm), C1 ICA (60‐70 mm), P1‐P2 PCA (average depth 63 mm (range 55‐75 mm), AComA (70‐80 mm), PComA (58‐65 mm), OA (40‐50 mm), ICA siphons (55‐65 mm), terminal VA (40‐75 mm), proximal (75‐80), mid (80‐90 mm), and distal (90‐110 mm) BA]. The distal ICA on the neck (40‐60 mm) can be located via submandibular windows to calculate the VMCA/VICA index, or the Lindegaard ratio for vasospasm grading after subarachnoid hemorrhage. Performance goals of diagnostic TCD are to detect and optimize arterial segment‐specific spectral waveforms, determine flow direction, measure cerebral blood flow velocities and flow pulsatility in the above‐mentioned arteries. These practice standards will assist laboratory accreditation processes by providing a standard scanning protocol with transducer positioning and orientation, depth selection and vessel identification for ultrasound devices equipped with spectral Doppler and power motion Doppler.

[1]  R. Aaslid,et al.  Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. , 1982, Journal of neurosurgery.

[2]  M. Nuwer,et al.  Assessment: Transcranial Doppler , 1990 .

[3]  R. Adams,et al.  Transcranial Doppler Correlation With Cerebral Angiography in Sickle Cell Disease , 1992, Stroke.

[4]  A. Alexandrov,et al.  Assessment: Transcranial Doppler ultrasonography: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology* , 2004, Neurology.

[5]  M. Hennerici,et al.  Transcranial Doppler ultrasound for the assessment of intracranial arterial flow velocity--Part 1. Examination technique and normal values. , 1987, Surgical neurology.

[6]  A. Alexandrov,et al.  Insonation Method and Diagnostic Flow Signatures for Transcranial Power Motion (M‐Mode) Doppler , 2002, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[7]  U. Bogdahn,et al.  Contrast‐Enhanced Transcranial Color‐Coded Real‐time Sonography: Results of a Phase‐Two Study , 1993, Stroke.

[8]  R. Aaslid Transcranial Doppler Examination Techniques , 1986 .

[9]  R G Gosling,et al.  Anatomical validation of middle cerebral artery position as identified by transcranial pulsed Doppler ultrasound. , 1986, Journal of neurology, neurosurgery, and psychiatry.

[10]  M. Kaps,et al.  Frontal bone windows for transcranial color-coded duplex sonography. , 1999, Stroke.

[11]  Arooj Shaikh,et al.  Ultrasound Diagnosis of Cerebrovascular Disease , 1994 .

[12]  W. Sorteberg,et al.  Cerebral vasospasm diagnosis by means of angiography and blood velocity measurements , 2005, Acta Neurochirurgica.

[13]  A. Alexandrov Cerebrovascular ultrasound in stroke prevention and treatment , 2004 .

[14]  R. Adams,et al.  Transcranial Doppler (TCD) screening for stroke prevention in sickle cell anemia: pitfalls in technique variation , 2000, Pediatric Radiology.

[15]  D F Hanley,et al.  Validation of transcranial Doppler ultrasound with a stereotactic neurosurgical technique. , 1995, Journal of neurosurgery.

[16]  R. Buchholz,et al.  Comparative study of transcranial color duplex sonography and transcranial Doppler sonography in adults. , 1993, Journal of neurosurgery.

[17]  L. Heytens,et al.  Transcranial Doppler sonography. , 1989, Acta neurologica Belgica.

[18]  M. Kaps,et al.  Imaging of the Intracranial Vertebrobasilar System Using Color‐Coded Ultrasound , 1992, Stroke.

[19]  E. Bartels,et al.  Quantitative Measurements of Blood Flow Velocity in Basal Cerebral Arteries with Transcranial Duplex Color‐Flow Imaging: A Comparative Study with Conventional Transcranial Doppler Sonography , 1994, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[20]  E. Feldmann,et al.  Transcranial Doppler Validation Pilot Study , 1993, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[21]  M. Hennerici,et al.  Vascular diagnosis with ultrasound: Clinical references with case studies , 1994 .

[22]  M. Moehring,et al.  Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli. , 2002, Ultrasound in medicine & biology.

[23]  I. Baumgartner,et al.  Comparative study of power-based versus mean frequency-based transcranial color-coded duplex sonography in normal adults. , 1996, Stroke.

[24]  R. Adams,et al.  The use of transcranial ultrasonography to predict stroke in sickle cell disease. , 1992, The New England journal of medicine.

[25]  J. Walter,et al.  Evaluation of the Vertebrobasilar–Posterior System by Transcranial Color Duplex Sonography in Adults , 1992, Stroke.

[26]  C. Machado Assessment: Transcranial Doppler ultrasonography: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology , 2004, Neurology.

[27]  L R Caplan,et al.  Transcranial Doppler Ultrasonography: Year 2000 Update , 2000, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[28]  R. Adams,et al.  Stroke Prevention in Sickle Cell Disease (STOP) Study Guidelines for Transcranial Doppler Testing , 2001, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[29]  E. Bartels,et al.  Color Doppler Imaging of Basal Cerebral Arteries: Normal Reference Values and Clinical Applications , 1995, Angiology.