Effect of the sterilization process on physical and mechanical properties of the Bonacryl bone cement

The use of bone cements of poly(methyl methacrylate) (PMMA) to fix artificial prosthesis to the human body is a habitual method in orthopedic surgery. The hip and the knee joints have a very complex biomechanics and support high loads, for these reasons, acrylic bone cements have to comply with international standards in order to secure the biofuncionality and durability of the implant. In this work we report the effect of sterilization by ethylene oxide or gamma radiation on the BONACRYL Cuban cement. We determined how sterilization methods affect the molecular weight of the polymer as well as its quasi-static mechanical properties. The results demonstrated that the gamma radiation modifies the molecular weight of the PMMA although the compression and bending strength were not affected by the sterilization process applied.

[1]  M. Meyyappan,et al.  Effects of gamma radiation on poly(methyl methacrylate)/single-wall nanotube composites , 2002 .

[2]  L. Pruitt,et al.  Fracture and fatigue properties of acrylic bone cement: the effects of mixing method, sterilization treatment, and molecular weight. , 2000, The Journal of arthroplasty.

[3]  Klaus-Dieter Kühn,et al.  Bone Cements: Up-to-Date Comparison of Physical and Chemical Properties of Commercial Materials , 2000 .

[4]  G. Lewis,et al.  Properties of acrylic bone cement: state of the art review. , 1997, Journal of biomedical materials research.

[5]  A H Burstein,et al.  Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption. , 1993, The Journal of bone and joint surgery. American volume.

[6]  H. Bertram,et al.  Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation. , 1990, Clinical orthopaedics and related research.

[7]  P. Beaumont,et al.  Fracture behaviour of commercial surgical acrylic bone cements. , 1979, Journal of biomedical engineering.

[8]  J. P. Taitsman,et al.  Tensile strength of wire-reinforced bone cement and twisted stainless-steel wire. , 1977, The Journal of bone and joint surgery. American volume.

[9]  S. Haas,et al.  A characterization of polymethylmethacrylate bone cement. , 1975, The Journal of bone and joint surgery. American volume.

[10]  Harper Ej,et al.  Development and characterisation of a hydroxyxapatite reinforced poly(ethylmethacrylate) bone cement. , 1996 .

[11]  P Ducheyne,et al.  Microstructural pathway of fracture in poly(methyl methacrylate) bone cement. , 1993, Biomaterials.

[12]  M. M. V. Solcines Optimización de la fijación prótesis-hueso en implantes articulares cementados , 1993 .

[13]  J. Steen Jensen,et al.  Additional mechanical tests of bone cements. , 1992, Acta orthopaedica Belgica.

[14]  J. Charnley Acrylic Cement in Orthopaedic Surgery , 1970 .