B0 mapping with multi‐channel RF coils at high field

Mapping the static magnetic field via the phase evolution over gradient echo scans acquired at two or more echo times is an established method. A number of possibilities exist, however, for combining phase data from multi‐channel coils, denoising and thresholding field maps for high field applications. Three methods for combining phase images when no body/volume coil is available are tested: (i) Hermitian product, (ii) phase‐matching over channels, and (iii) a new approach based on calculating separate field maps for each channel. The separate channel method is shown to yield field maps with higher signal‐to‐noise ratio than the Hermitian product and phase‐matching methods and fewer unwrapping errors at low signal‐to‐noise ratio. Separate channel combination also allows unreliable voxels to be identified via the standard deviation over channels, which is found to be the most effective means of denoising field maps. Tests were performed using multichannel coils with between 8 and 32 channels at 3 T, 4 T, and 7 T. For application in the correction of distortions in echo‐planar images, a formulation is proposed for reducing the local gradient of field maps to eliminate signal pile‐up or swapping artifacts. Field maps calculated using these techniques, implemented in a freely available MATLAB toolbox, provide the basis for an effective correction for echo‐planar imaging distortions at high fields. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.

[1]  Mark Jenkinson,et al.  Improved unwarping of EPI images using regularised B0 maps , 2001, NeuroImage.

[2]  M Zaitsev,et al.  Point spread function mapping with parallel imaging techniques and high acceleration factors: Fast, robust, and flexible method for echo‐planar imaging distortion correction , 2004, Magnetic resonance in medicine.

[3]  R Todd Constable,et al.  Image distortion correction in EPI: Comparison of field mapping with point spread function mapping , 2002, Magnetic resonance in medicine.

[4]  Max A. Viergever,et al.  MR venography of the human brain using susceptibility weighted imaging at very high field strength , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[5]  J. Hajnal,et al.  Artifacts due to stimulus correlated motion in functional imaging of the brain , 1994, Magnetic resonance in medicine.

[6]  Z. Cho,et al.  Improved PSF-based EPI Distortion Correction in Human Imaging at 7 Tesla , 2009 .

[7]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[8]  Mark Bydder,et al.  Optimal phase difference reconstruction: comparison of two methods. , 2008, Magnetic resonance imaging.

[9]  K. Scharnhorst,et al.  Angles in Complex Vector Spaces , 1999 .

[10]  Christine Preibisch,et al.  Rapid single‐scan T  2* ‐mapping using exponential excitation pulses and image‐based correction for linear background gradients , 2009, Magnetic resonance in medicine.

[11]  N J Pelc,et al.  Reconstructions of phase contrast, phased array multicoil data , 1994, Magnetic resonance in medicine.

[12]  L. Wald,et al.  32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry , 2006, Magnetic resonance in medicine.

[13]  R. S. Hinks,et al.  Spin‐echo and gradient‐echo epi of human brain activation using bold contrast: A comparative study at 1.5 T , 1994, NMR in biomedicine.

[14]  Peter Boesiger,et al.  Comparison of fMRI activation as measured with gradient- and spin-echo EPI during visual perception , 2005, NeuroImage.

[15]  J. Polimeni,et al.  96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation , 2009, Magnetic resonance in medicine.

[16]  Markus Barth,et al.  Phase unwrapping of MR images using ΦUN - A fast and robust region growing algorithm , 2009, Medical Image Anal..

[17]  Mark Jenkinson,et al.  Fast, automated, N‐dimensional phase‐unwrapping algorithm , 2003, Magnetic resonance in medicine.

[18]  Robert Turner,et al.  Image Distortion Correction in fMRI: A Quantitative Evaluation , 2002, NeuroImage.

[19]  Nikolaus Weiskopf,et al.  Optimal EPI parameters for reduction of susceptibility-induced BOLD sensitivity losses: A whole-brain analysis at 3 T and 1.5 T , 2006, NeuroImage.

[20]  Zhaolin Chen,et al.  An optimised framework for reconstructing and processing MR phase images , 2010, NeuroImage.

[21]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[22]  Jianrong Shi,et al.  Phase labeling using sensitivity encoding (PLUS): Data acquisition and image reconstruction for geometric distortion correction in EPI , 2009, Magnetic resonance in medicine.

[23]  D G Norris,et al.  Functional MRI of the human brain with GRASE‐based BOLD contrast , 1999, Magnetic resonance in medicine.

[24]  Daniel B. Vigneron,et al.  Development of a robust method for generating 7.0 T multichannel phase images of the brain with application to normal volunteers and patients with neurological diseases , 2008, NeuroImage.

[25]  Jeff H. Duyn,et al.  High-field MRI of brain cortical substructure based on signal phase , 2007, Proceedings of the National Academy of Sciences.

[26]  P. Reber,et al.  Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps , 1998, Magnetic resonance in medicine.

[27]  T. Schaeffter,et al.  Limits of detection of SPIO at 3.0 T using T2* relaxometry , 2005, Magnetic resonance in medicine.

[28]  Stephen M Smith,et al.  Fast robust automated brain extraction , 2002, Human brain mapping.

[29]  P. Jezzard,et al.  Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.

[30]  F. Ye,et al.  Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE) , 2007, Magnetic resonance in medicine.

[31]  Matts Karlsson,et al.  Comparison of different methods for combining phase-contrast images obtained with multiple coils. , 2005, Magnetic resonance imaging.

[32]  J. Jovicich,et al.  Fast , high resolution T 2 * mapping using 3 D MGE and 3 D EPI , with 3 D correction for macroscopic dephasing effects , 2008 .

[33]  Siegfried Trattnig,et al.  Combining phase images from multi‐channel RF coils using 3D phase offset maps derived from a dual‐echo scan , 2011, Magnetic resonance in medicine.

[34]  Ewald Moser,et al.  Robust field map generation using a triple‐echo acquisition , 2004, Journal of magnetic resonance imaging : JMRI.

[35]  A M Wyrwicz,et al.  Correction for EPI distortions using multi‐echo gradient‐echo imaging , 1999, Magnetic resonance in medicine.