Experimental analysis of a direct expansion solar assisted heat pump with integral storage tank for domestic water heating under zero solar radiation conditions

Abstract This paper deals with the experimental evaluation of the performance of a direct expansion solar assisted heat pump water heating (DX-SAHPWH) system working under zero solar radiation conditions at static heating operation mode of the storage tank. The DX-SAHPWH system includes two bare solar collectors as evaporator, a R134a rotary-type hermetic compressor, a thermostatic expansion valve and a helical coil condenser immersed in a 300 L water storage tank. The zero solar radiation and stable ambient air temperature working conditions were established by placing the solar collectors into a climate chamber. The analysis is based on experimental data taken from the DX-SAHPWH provided by the manufacturer and equipped with an appropriate data acquisition system. In the paper, the experimental facility, the data acquisition system and the experimental methodology are described. Performance parameters to evaluate the energy efficiency, such as COP and equivalent seasonal performance factors (SPFe) for the heating period, and the water thermal stratification in the storage tank are defined and obtained from the experimental data. Results from the experimental analysis under transient operating working conditions of the DX-SAHPWH system and its main components are shown and discussed. Lastly, the Huang and Lee DX-SAHPWH performance evaluation method was applied resulting in a characteristic COP of 3.23 for the DX-SAHPWH system evaluated under zero solar radiation condition.

[1]  E. A. Kush Performance of Heat Pumps at Elevated Evaporating Temperatures—With Application to Solar Input , 1979 .

[2]  Bin-Juine Huang,et al.  Performance evaluation method of solar-assisted heat pump water heater , 2007 .

[3]  G. Morrison,et al.  Effect of load pattern on solar-boosted heat pump water heater performance , 2007 .

[4]  Sushil K. Chaturvedi,et al.  Analysis of a direct expansion solar assisted heat pump using different refrigerants , 2005 .

[5]  S. Ito,et al.  PERFORMANCE OF A HEAT PUMP USING DIRECT EXPANSION SOLAR COLLECTORS 1 Paper presented at the ISES Sol , 1999 .

[6]  Ruzhu Wang,et al.  Study on a direct‐expansion solar‐assisted heat pump water heating system , 2003 .

[7]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 8.0 , 2007 .

[8]  Arif Hepbasli,et al.  A review of heat pump water heating systems , 2009 .

[9]  Mohammad Nurul Alam Hawlader,et al.  Performance of evaporator-collector and air collector in solar assisted heat pump dryer , 2008 .

[10]  S. Chaturvedi,et al.  Thermal performance of a direct expansion solar-assisted heat pump , 1984 .

[11]  A. Nilufer Egrican Performance of a solar assisted heat pump system , 1991 .

[12]  Bin-Juine Huang,et al.  Long-term performance of solar-assisted heat pump water heater , 2004 .

[13]  Bin-Juine Huang,et al.  Performance characteristics of integral type solar-assisted heat pump , 2001 .

[14]  Masud Behnia,et al.  Seasonal Performance Rating of Heat Pump Water Heaters , 2004 .

[15]  Shahab Sokhansanj,et al.  A dynamic performance simulation model of flat-plate solar collectors for a heat pump system , 1993 .

[16]  S. Chaturvedi,et al.  Thermal performance of a variable capacity direct expansion solar-assisted heat pump , 1998 .