Potential for unreliable interpretation of EEG recorded with microelectrodes

Recent studies in epilepsy, cognition, and brain machine interfaces have shown the utility of recording intracranial electroencephalography (iEEG) with greater spatial resolution. Many of these studies utilize microelectrodes connected to specialized amplifiers that are optimized for such recordings. We recently measured the impedances of several commercial microelectrodes and demonstrated that they will distort iEEG signals if connected to clinical EEG amplifiers commonly used in most centers. In this study we demonstrate the clinical implications of this effect and identify some of the potential difficulties in using microelectrodes.

[1]  Brian Litt,et al.  A stochastic framework for evaluating seizure prediction algorithms using hidden Markov models. , 2007, Journal of neurophysiology.

[2]  Richard A Normann,et al.  Technology Insight: future neuroprosthetic therapies for disorders of the nervous system , 2007, Nature Clinical Practice Neurology.

[3]  Justin A. Blanco,et al.  Unsupervised classification of high-frequency oscillations in human neocortical epilepsy and control patients. , 2010, Journal of neurophysiology.

[4]  C. Koch,et al.  Invariant visual representation by single neurons in the human brain , 2005, Nature.

[5]  C. Schevon,et al.  Propagation of Epileptiform Activity on a Submillimeter Scale , 2010, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[6]  E. Halgren,et al.  Single-neuron dynamics in human focal epilepsy , 2011, Nature Neuroscience.

[7]  Jean Gotman,et al.  Contact size does not affect high frequency oscillation detection in intracerebral EEG recordings in a rat epilepsy model , 2011, Clinical Neurophysiology.

[8]  Itzhak Fried,et al.  Interictal high‐frequency oscillations (80–500Hz) in the human epileptic brain: Entorhinal cortex , 2002, Annals of neurology.

[9]  R. Yuste,et al.  Evidence of an inhibitory restraint of seizure activity in humans , 2012, Nature Communications.

[10]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[11]  Charles L. Wilson,et al.  Quantitative analysis of high-frequency oscillations (80-500 Hz) recorded in human epileptic hippocampus and entorhinal cortex. , 2002, Journal of neurophysiology.

[12]  Itzhak Fried,et al.  Large-Scale Microelectrode Recordings of High-Frequency Gamma Oscillations in Human Cortex during Sleep , 2010, The Journal of Neuroscience.

[13]  Andrew B. Gardner,et al.  Comparison of novel computer detectors and human performance for spike detection in intracranial EEG , 2007, Clinical Neurophysiology.

[14]  J. M. Lina,et al.  Recording and analysis techniques for high-frequency oscillations , 2012, Progress in Neurobiology.

[15]  B. P. Lathi Linear systems and signals , 1992 .

[16]  Mark R. Bower,et al.  Microseizures and the spatiotemporal scales of human partial epilepsy. , 2010, Brain : a journal of neurology.

[17]  Justin A. Blanco,et al.  Data mining neocortical high-frequency oscillations in epilepsy and controls. , 2011, Brain : a journal of neurology.

[18]  E. McAdams,et al.  Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  H. Kraemer,et al.  Interrater reliability of EEG-video monitoring , 2009, Neurology.

[20]  C. Schroeder,et al.  Spatial characterization of interictal high frequency oscillations in epileptic neocortex , 2009, Brain : a journal of neurology.

[21]  Spencer Kellis,et al.  Signal distortion from microelectrodes in clinical EEG acquisition systems , 2012, Journal of neural engineering.

[22]  T S Davis,et al.  Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque , 2012, Journal of neural engineering.

[23]  Caterina Giannini,et al.  Phase I trial: safety and feasibility of intracranial electroencephalography using hybrid subdural electrodes containing macro- and microelectrode arrays. , 2008, Neurosurgical focus.