In-cycle myocardium tissue electrical impedance monitoring using broadband impedance spectroscopy

Measurements of myocardium tissue impedance during the cardiac cycle have information about the morphology of myocardium cells as well as cell membranes and intra/extra cellular spaces. Although the variation with time of the impedance cardiac signal has information about the myocardium tissue activity during the cardiac cycle, this information has been usually underestimated in the studies based on frequency-sweep Electrical Impedance Spectroscopy (EIS) technique. In these cases, the dynamic behavior was removed from the impedance by means of averaging. The originality of this research is to show the time evolution of in-vivo healthy myocardium tissue impedance during the cardiac cycle, being measured with a multisine excitation at 26 frequencies (1 kHz–1 MHz). The obtained parameters from fitting data to a Cole model are valid indicators to explain the time relation of the systolic and diastolic function with respect to the myocardium impedance time variation. This paper presents a successful application of broadband Impedance Spectroscopy for time-varying impedance monitoring. Furthermore, it can be extended to understand various unsolved problems in a wide range of biomedical and electrochemical applications, where the system dynamics are intended to be studied.

[1]  K. Cole,et al.  Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics , 1941 .

[2]  Dispersion and Absorption in Dielectrics 1 , 2022 .

[3]  Gerd Vandersteen,et al.  Novel Estimation of the Electrical Bioimpedance Using the Local Polynomial Method. Application to In Vivo Real-Time Myocardium Tissue Impedance Characterization During the Cardiac Cycle , 2011, IEEE Transactions on Biomedical Engineering.

[4]  Yolocuauhtli Salazar,et al.  Changes in myocardial electrical impedance in human heart graft rejection , 2008, European journal of heart failure.

[5]  E. Gersing,et al.  Messung der elektrischen Impedanz von Organen — Apparative Ausrüstung für Forschung und klinische Anwendung - Measurement of Electrical Impedance in Organs – Measuring Equipment for Research and Clinical Applications , 1991 .

[6]  Yves Rolain,et al.  Improved (non-)parametric identification of dynamic systems excited by periodic signals—The multivariate case , 2011 .

[7]  Ramon Bragós,et al.  Transmural versus nontransmural in situ electrical impedance spectrum for healthy, ischemic, and healed myocardium , 2004, IEEE Transactions on Biomedical Engineering.

[8]  C. Davis,et al.  Impedance spectroscopy of human erythrocytes: system calibration, and nonlinear modeling , 1993, IEEE Transactions on Biomedical Engineering.

[9]  J. Rosell,et al.  Characterisation of dynamic biologic systems using multisine based impedance spectroscopy , 2001, IMTC 2001. Proceedings of the 18th IEEE Instrumentation and Measurement Technology Conference. Rediscovering Measurement in the Age of Informatics (Cat. No.01CH 37188).

[10]  K R Foster,et al.  Myocardial Electrical Impedance Mapping of Ischemic Sheep Hearts and Healing Aneurysms , 1993, Circulation.

[11]  E Gersing,et al.  Impedance Spectroscopy: a Method for Surveillance of Ischemia Tolerance of the Heart , 1987, The Thoracic and cardiovascular surgeon.

[12]  R Hetzer,et al.  Electric myocardial impedance registration in humoral rejection after heart transplantation. , 1996, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.