Electromagnetic articulograph (EMA) based on a nonparametric representation of tthe magnetic field

Electromagnetic articulograph (EMA) devices are capable of measuring movements of the articulatory organs inside and outside the vocal tract with fine spatial and temporal resolutions, thus providing useful articulatory data for investigating the speech production process. The position of the receiver coil is detected in the EMA device on the basis of a field function representing the spatial pattern of the magnetic field in relation to the relative positions of the transmitter and receiver coils. Therefore, the design and calibration of the field function are quite important and influence the accuracy of position detection. This paper presents a nonparametric method for representing the magnetic field, and also describes a method for determining the receiver position from the strength of the induced signal in the receiver coil. The field pattern in this method is expressed by using a multivariate spline as a function of the position in the device's coordinate system. Because of the piecewise property of the basis functions and the freedom in the selection of the rank and the number of the basis functions, the spline function has a superior ability to flexibly and accurately represent the field pattern, even when it suffers from fluctuations caused by the interference between the transmitting channels. The position of the receiver coil is determined by minimizing the difference between the measured strength of the received signal and the predicted one from the spline representation of the magnetic field. Experimental results show that the error in estimating the receiver position is less than 0.1 mm for a 14 x 14-cm measurement area, and this error can be further reduced by using a spline-smoothing technique.

[1]  M. Stone,et al.  Three-dimensional tongue surface shapes of English consonants and vowels. , 1996, The Journal of the Acoustical Society of America.

[2]  T Kaburagi,et al.  Dynamic articulatory model based on multidimensional invariant-feature task representation. , 2001, The Journal of the Acoustical Society of America.

[3]  Masaaki Honda,et al.  Calibration methods of voltage-to-distance function for an electromagnetic articulometer (EMA) system , 1997 .

[4]  Y. Sonoda,et al.  Observation of tongue movements employing magnetometer sensor , 1974 .

[5]  Masaaki Honda,et al.  Determination of articulatory positions from speech acoustics by applying dynamic articulatory constraints , 1998, ICSLP.

[6]  Philip Hoole Methodological considerations in the use of electromagnetic articulography in phonetic research , 1993 .

[7]  F. Raab,et al.  Magnetic Position and Orientation Tracking System , 1979, IEEE Transactions on Aerospace and Electronic Systems.

[8]  M. Stone A three-dimensional model of tongue movement based on ultrasound and x-ray microbeam data. , 1990, The Journal of the Acoustical Society of America.

[9]  S Kiritani,et al.  Computer controlled radiography for observation of movements of articulatory and other human organs. , 1973, Computers in biology and medicine.

[10]  M H Cohen,et al.  Electromagnetic midsagittal articulometer systems for transducing speech articulatory movements. , 1992, The Journal of the Acoustical Society of America.

[11]  T. Kaburagi,et al.  Determination of sagittal tongue shape from the positions of points on the tongue surface. , 1994, The Journal of the Acoustical Society of America.

[12]  Andreas Zierdt,et al.  DEVELOPMENT OF A SYSTEM FOR THREE-DIMENSIONAL FLESHPOINT MEASUREMENT OF SPEECH MOVEMENTS , 1999 .

[13]  O. Fujimura,et al.  Tongue-pellet tracking by a computer-controlled x-ray microbeam system;. , 1975, The Journal of the Acoustical Society of America.

[14]  K A Morrish,et al.  Characterization of tongue shape. , 1984, Ultrasonic imaging.

[15]  C. D. Boor,et al.  On Calculating B-splines , 1972 .

[16]  A. Zierdt Problems of electromagnetic position transduction for a three-dimensional articulographic measurement system , 1993 .

[17]  A. H. Rich,et al.  Cross-sectional tongue shape during the production of vowels. , 1988, The Journal of the Acoustical Society of America.

[18]  Masaaki Honda,et al.  Determination of the vocal tract spectrum from the articulatory movements based on the search of an articulatory-acoustic database , 1998, ICSLP.

[19]  C. Micchelli,et al.  On multivariate -splines , 1989 .

[20]  P. Schönle,et al.  Electromagnetic articulography: Use of alternating magnetic fields for tracking movements of multiple points inside and outside the vocal tract , 1987, Brain and Language.

[21]  T. Shawker,et al.  Tongue pellet tracking by ultrasound: development of a reverberation pellet , 1985 .

[22]  John E. Dennis,et al.  Numerical methods for unconstrained optimization and nonlinear equations , 1983, Prentice Hall series in computational mathematics.

[23]  Andreas Zierdt,et al.  Towards a three‐dimensional articulographic system , 1996 .

[24]  T. Hixon An Electromagnetic Method for Transducing Jaw Movements during Speech , 1971 .

[25]  Patrick W. Nye,et al.  Magnetometry in speech articulation research: some misadventures on the road to enlightenment , 1993 .

[26]  Masaaki Honda,et al.  EXTRACTING TONGUES FROM MOVING HEADS , 2000 .

[27]  Masaaki Honda,et al.  Three-dimensional electromagnetic articulograph based on a nonparametric representation of the magnetic field , 2002, INTERSPEECH.

[28]  Paul Dierckx,et al.  Curve and surface fitting with splines , 1994, Monographs on numerical analysis.

[29]  J A Kelso,et al.  An evaluation of an alternating magnetic field device for monitoring tongue movements. , 1990, The Journal of the Acoustical Society of America.