PET quantification: strategies for partial volume correction

[1]  M C Gilardi,et al.  Metabolic impact of partial volume correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment. , 2014, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....

[2]  Habib Zaidi,et al.  Isotope specific resolution recovery image reconstruction in high resolution PET imaging. , 2014, Medical physics.

[3]  I Sassi,et al.  Partial volume corrected 18F-FDG PET mean standardized uptake value correlates with prognostic factors in breast cancer. , 2014, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....

[4]  S. Hapdey,et al.  Management of respiratory motion in PET/computed tomography: the state of the art , 2014, Nuclear medicine communications.

[5]  Paul Marsden,et al.  Estimation of input functions from dynamic [18F]FLT PET studies of the head and neck with correction for partial volume effects , 2013, EJNMMI Research.

[6]  Tohru Shiga,et al.  Outcome analysis of (18)F-fluorodeoxyglucose positron-emission tomography in patients with lung cancer after partial volume correction. , 2013, Anticancer research.

[7]  Ciprian Catana,et al.  Influence of the partial volume correction method on 18F-fluorodeoxyglucose brain kinetic modelling from dynamic PET images reconstructed with resolution model based OSEM , 2013, Physics in medicine and biology.

[8]  Martin A Lodge,et al.  Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation , 2013, Physics in medicine and biology.

[9]  I. Castiglioni,et al.  A Partial Volume Effect Correction Tailored for 18F-FDG-PET Oncological Studies , 2013, BioMed research international.

[10]  Arman Rahmim,et al.  Resolution modeling in PET imaging: Theory, practice, benefits, and pitfalls. , 2013, Medical physics.

[11]  Thomas Beyer,et al.  Clinical evaluation of PET image reconstruction using a spatial resolution model. , 2013, European journal of radiology.

[12]  Quanzheng Li,et al.  Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study , 2013, Physics in medicine and biology.

[13]  A. Alavi,et al.  PET/MR imaging: technical aspects and potential clinical applications. , 2013, Radiology.

[14]  C. Fulcheri,et al.  Improvement in clinical evaluation of PET/CT images with high resolution algorithms. , 2013, The Quarterly Journal of Nuclear Medicine and Molecular Imaging.

[15]  Michael Casey,et al.  Clinical impact of time-of-flight and point response modeling in PET reconstructions: a lesion detection study , 2013, Physics in medicine and biology.

[16]  M. Hatt,et al.  Comparison Between 18F-FDG PET Image–Derived Indices for Early Prediction of Response to Neoadjuvant Chemotherapy in Breast Cancer , 2013, The Journal of Nuclear Medicine.

[17]  Elena Prieto,et al.  Impact of Time-of-Flight and Point-Spread-Function in SUV Quantification for Oncological PET , 2013, Clinical nuclear medicine.

[18]  R. Leahy,et al.  Magnetic resonance-guided positron emission tomography image reconstruction. , 2013, Seminars in nuclear medicine.

[19]  I. Castiglioni,et al.  Predictive value of pre-therapy 18F-FDG PET/CT for the outcome of 18F-FDG PET-guided radiotherapy in patients with head and neck cancer , 2013, European Journal of Nuclear Medicine and Molecular Imaging.

[20]  G. Fung,et al.  Compensation for spill-in and spill-out partial volume effects in cardiac PET imaging , 2013, Journal of Nuclear Cardiology.

[21]  S. Nekolla,et al.  Quantitative assessment of glucose metabolism in the vessel wall of abdominal aortic aneurysms: correlation with histology and role of partial volume correction , 2013, The International Journal of Cardiovascular Imaging.

[22]  Habib Zaidi,et al.  Anatomically guided voxel-based partial volume effect correction in brain PET: Impact of MRI segmentation , 2012, Comput. Medical Imaging Graph..

[23]  I. Buvat,et al.  Comparison of PET metabolic indices for the early assessment of tumour response in metastatic colorectal cancer patients treated by polychemotherapy , 2012, European Journal of Nuclear Medicine and Molecular Imaging.

[24]  I. Buvat,et al.  A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology , 2012, Physics in medicine and biology.

[25]  G. Zalcman,et al.  Impact of Point Spread Function Reconstruction on Thoracic Lymph Node Staging With 18F-FDG PET/CT in Non–Small Cell Lung Cancer , 2012, Clinical nuclear medicine.

[26]  V. Bettinardi,et al.  Motion management in positron emission tomography/computed tomography for radiation treatment planning. , 2012, Seminars in nuclear medicine.

[27]  Ciprian Catana,et al.  MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI , 2012, The Journal of Nuclear Medicine.

[28]  Y. D'Asseler,et al.  Standardized added metabolic activity (SAM): a partial volume independent marker of total lesion glycolysis in liver metastases , 2012, European Journal of Nuclear Medicine and Molecular Imaging.

[29]  M. Aznar,et al.  Innovations in PET/CT. , 2012, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....

[30]  Ian Poon,et al.  Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness , 2012, Physics in medicine and biology.

[31]  Stefan P. Müller,et al.  Improved Regional Activity Quantitation in Nuclear Medicine Using a New Approach to Correct for Tissue Partial Volume and Spillover Effects , 2012, IEEE Transactions on Medical Imaging.

[32]  Dimitris Visvikis,et al.  Author manuscript, published in "Journal of Nuclear Medicine 2012;53(1):12-20" DOI: 10.2967/jnumed.111.092775 , 2012 .

[33]  F. Turkheimer,et al.  Evaluation of a 3D local multiresolution algorithm for the correction of partial volume effects in positron emission tomography. , 2011, Medical physics.

[34]  Kewei Chen,et al.  Image-Derived Input Function for Brain PET Studies: Many Challenges and Few Opportunities , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[35]  S. Vallabhajosula,et al.  A broad overview of positron emission tomography radiopharmaceuticals and clinical applications: what is new? , 2011, Seminars in nuclear medicine.

[36]  G El Fakhri,et al.  Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging. , 2011, Medical physics.

[37]  A. Jackson,et al.  Single scan parameterization of space-variant point spread functions in image space via a printed array: the impact for two PET/CT scanners , 2011, Physics in medicine and biology.

[38]  Dimitris Visvikis,et al.  Baseline 18F-FDG PET image-derived parameters for therapy response prediction in oesophageal cancer , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[39]  Kris Thielemans,et al.  Edge artifacts in PSF-based PET image reconstruction: Characterization and mitigation , 2011 .

[40]  J. Karp,et al.  Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET , 2011, The Journal of Nuclear Medicine.

[41]  M C Gilardi,et al.  PVE Correction in PET-CT Whole-Body Oncological Studies From PVE-Affected Images , 2011, IEEE Transactions on Nuclear Science.

[42]  M. Modat,et al.  The importance of appropriate partial volume correction for PET quantification in Alzheimer’s disease , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[43]  Piotr J. Slomka,et al.  Motion frozen 18F-FDG cardiac PET , 2010, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[44]  Rakesh Kumar,et al.  Pediatric lymphoma: metabolic tumor burden as a quantitative index for treatment response evaluation , 2011, Annals of Nuclear Medicine.

[45]  D. Groheux,et al.  Correlation of high 18F-FDG uptake to clinical, pathological and biological prognostic factors in breast cancer , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[46]  John W. Clark,et al.  Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging. , 2010, Medical physics.

[47]  Thomas K Lewellen,et al.  The challenge of detector designs for PET. , 2010, AJR. American journal of roentgenology.

[48]  Roger Lecomte,et al.  Image-derived input function in dynamic human PET/CT: methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[49]  Sven Kabus,et al.  Combined correction of recovery effect and motion blur for SUV quantification of solitary pulmonary nodules in FDG PET/CT , 2010, European Radiology.

[50]  Steven G. Ross,et al.  Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction , 2010, IEEE Transactions on Medical Imaging.

[51]  R. Boellaard,et al.  Partial volume correction strategies for quantitative FDG PET in oncology , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[52]  John Dickson,et al.  Evaluation of an OSEM-based PVC method for SPECT with clinical data , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[53]  Tommi Noponen,et al.  Dual-gated cardiac PET–Clinical feasibility study , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[54]  Brian Hutton,et al.  Partial Volume Correction in SPECT Using Anatomical Information and Iterative FBP , 2010 .

[55]  Habib Zaidi,et al.  Four-dimensional (4D) image reconstruction strategies in dynamic PET: beyond conventional independent frame reconstruction. , 2009, Medical physics.

[56]  D. Townsend,et al.  Impact of Time-of-Flight on PET Tumor Detection , 2009, Journal of Nuclear Medicine.

[57]  Suleman Surti,et al.  A recovery coefficient method for partial volume correction of PET images , 2009, Annals of nuclear medicine.

[58]  Maurizio Conti,et al.  State of the art and challenges of time-of-flight PET. , 2009, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[59]  D. Visvikis,et al.  Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[60]  Alexander Hammers,et al.  Functional and structural synergy for resolution recovery and partial volume correction in brain PET , 2009, NeuroImage.

[61]  David Izquierdo-Garcia,et al.  Comparison of Methods for Magnetic Resonance-Guided [18-F]Fluorodeoxyglucose Positron Emission Tomography in Human Carotid Arteries: Reproducibility, Partial Volume Correction, and Correlation Between Methods , 2009, Stroke.

[62]  A. Hölscher,et al.  Mean and maximum standardized uptake values in [18F]FDG-PET for assessment of histopathological response in oesophageal squamous cell carcinoma or adenocarcinoma after radiochemotherapy , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[63]  David W. Townsend,et al.  Positon emission tomography: basic science and clinical practice , 2008 .

[64]  J. Hodler,et al.  The additional value of CT images interpretation in the differential diagnosis of benign vs. malignant primary bone lesions with 18F-FDG-PET/CT , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[65]  Andrew J. Reader,et al.  Impact of Image-Space Resolution Modeling for Studies with the High-Resolution Research Tomograph , 2008, Journal of Nuclear Medicine.

[66]  A. Kirov,et al.  Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology , 2008, Physics in medicine and biology.

[67]  Anthonin Reilhac,et al.  Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method , 2008, NeuroImage.

[68]  Ronald Boellaard,et al.  Partial volume corrected image derived input functions for dynamic PET brain studies: Methodology and validation for [11C]flumazenil , 2008, NeuroImage.

[69]  H. Zaidi,et al.  Quantitative Analysis in Nuclear Medicine Imaging , 2007, Journal of Nuclear Medicine.

[70]  O. Nevalainen,et al.  Evaluation of partial volume effect correction methods for brain positron emission tomography: Quantification and reproducibility , 2007, Journal of medical physics.

[71]  I. Buvat,et al.  Partial-Volume Effect in PET Tumor Imaging* , 2007, Journal of Nuclear Medicine.

[72]  S. Libutti,et al.  Partial-Volume Correction in PET: Validation of an Iterative Postreconstruction Method with Phantom and Patient Data , 2007, Journal of Nuclear Medicine.

[73]  Habib Zaidi,et al.  Partial Volume Correction Strategies in PET. , 2007, PET clinics.

[74]  H. Zaidi,et al.  Advances in PET Image Reconstruction. , 2007, PET clinics.

[75]  H. Zaidi,et al.  Tracer Kinetic Modeling in PET. , 2007, PET clinics.

[76]  Andreas Robert Formiconi,et al.  A direct ROI quantification method for inherent PVE correction: accuracy assessment in striatal SPECT measurements , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[77]  Nassir Navab,et al.  Dual cardiac–respiratory gated PET: implementation and results from a feasibility study , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[78]  A J Reader,et al.  Respiratory motion correction for PET oncology applications using affine transformation of list mode data , 2007, Physics in medicine and biology.

[79]  M C Gilardi,et al.  Using Deconvolution to Improve PET Spatial Resolution in OSEM Iterative Reconstruction , 2007, Methods of Information in Medicine.

[80]  Habib Zaidi,et al.  Comparative assessment of statistical brain MR image segmentation algorithms and their impact on partial volume correction in PET , 2006, NeuroImage.

[81]  John W. Clark,et al.  A motion-incorporated reconstruction method for gated PET studies , 2006, Physics in medicine and biology.

[82]  Vladimir Y. Panin,et al.  Fully 3-D PET reconstruction with system matrix derived from point source measurements , 2006, IEEE Transactions on Medical Imaging.

[83]  Lawrence H Schwartz,et al.  18F-FDG PET as a candidate for "qualified biomarker": functional assessment of treatment response in oncology. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[84]  Joel Karp,et al.  Consensus recommendations for the use of 18F-FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[85]  D Visvikis,et al.  A multiresolution image based approach for correction of partial volume effects in emission tomography , 2006, Physics in medicine and biology.

[86]  Habib Zaidi,et al.  Correction for Partial Volume Effects in Emission Tomography , 2006 .

[87]  Arman Rahmim,et al.  Advanced Motion Correction Methods in PET , 2005 .

[88]  Yong Du,et al.  Partial volume effect compensation for quantitative brain SPECT imaging , 2005, IEEE Transactions on Medical Imaging.

[89]  Kazuyoshi Yajima,et al.  Brain FDG PET study of normal aging in Japanese: effect of atrophy correction , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[90]  Richard E. Carson,et al.  Tracer Kinetic Modeling in PET , 2005 .

[91]  Guido Germano,et al.  "Motion-frozen" display and quantification of myocardial perfusion. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[92]  Pietro Pietrini,et al.  Resting state brain glucose metabolism is not reduced in normotensive healthy men during aging, after correction for brain atrophy , 2004, Brain Research Bulletin.

[93]  C. Svarer,et al.  Integrated software for the analysis of brain PET/SPECT studies with partial-volume-effect correction. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[94]  Andrew J. Reader,et al.  EM algorithm system modeling by image-space techniques for PET reconstruction , 2003 .

[95]  Michael E Casey,et al.  PET performance measurements using the NEMA NU 2-2001 standard. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[96]  Alan C. Evans,et al.  Positron Emission Tomography Partial Volume Correction: Estimation and Algorithms , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[97]  M N Cantwell,et al.  Does cerebral blood flow decline in healthy aging? A PET study with partial-volume correction. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[98]  A. Gjedde,et al.  Effect of partial volume correction on estimates of the influx and cerebral metabolism of 6‐[18F]fluoro‐L‐dopa studied with PET in normal control and Parkinson's disease subjects , 2000, Synapse.

[99]  Richard M. Leahy,et al.  Statistical approaches in quantitative positron emission tomography , 2000, Stat. Comput..

[100]  M Schwaiger,et al.  Reproducibility of metabolic measurements in malignant tumors using FDG PET. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[101]  D. Feng,et al.  Noninvasive Quantification of the Cerebral Metabolic Rate for Glucose Using Positron Emission Tomography, 18F-Fluoro-2-Deoxyglucose, the Patlak Method, and an Image-Derived Input Function , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[102]  G. Alexander,et al.  Regional glucose metabolic abnormalities are not the result of atrophy in Alzheimer's disease , 1998, Neurology.

[103]  A. Evans,et al.  Correction for partial volume effects in PET: principle and validation. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[104]  Raymond F. Muzic,et al.  A method to correct for scatter, spillover, and partial volume effects in region of interest analysis in PET , 1998, IEEE Transactions on Medical Imaging.

[105]  M. Daube-Witherspoon,et al.  Quantitative functional brain imaging with positron emission tomography , 1998 .

[106]  Alan C. Evans,et al.  Pixel- versus Region-Based Partial Volume Correction in PET 1 1Transcripts of the BRAINPET97 discussion of this chapter can be found in Section VIII. , 1998 .

[107]  J. Litton,et al.  Input function in PET brain studies using MR-defined arteries. , 1997, Journal of computer assisted tomography.

[108]  J. M. Ollinger,et al.  Positron Emission Tomography , 2018, Handbook of Small Animal Imaging.

[109]  Arthur W. Toga,et al.  Investigation of partial volume correction methods for brain FDG PET studies , 1996 .

[110]  Jonathan M. Links,et al.  MR-Based Correction of Brain PET Measurements for Heterogeneous Gray Matter Radioactivity Distribution , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[111]  Andreas Robert Formiconi,et al.  Least squares algorithm for region-of-interest evaluation in emission tomography , 1993, IEEE Trans. Medical Imaging.

[112]  Jerry L Prince,et al.  Measurement of Radiotracer Concentration in Brain Gray Matter Using Positron Emission Tomography: MRI-Based Correction for Partial Volume Effects , 1992, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[113]  G. Hutchins,et al.  A region of interest strategy for minimizing resolution distortions in quantitative myocardial PET studies. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[114]  H. Iida,et al.  Myocardial tissue fraction--correction for partial volume effects and measure of tissue viability. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[115]  H. Mayberg,et al.  Correction of PET Data for Partial Volume Effects in Human Cerebral Cortex by MR Imaging , 1990, Journal of computer assisted tomography.

[116]  M E Raichle,et al.  Regional Correction of Positron Emission Tomography Data for the Effects of Cerebral Atrophy , 1988, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[117]  R. Carson A Maximum Likelihood Method for Region-of-Interest Evaluation in Emission Tomography , 1986, Journal of computer assisted tomography.

[118]  R. Kessler,et al.  Analysis of emission tomographic scan data: limitations imposed by resolution and background. , 1984, Journal of computer assisted tomography.

[119]  R. Huesman A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography. , 1984, Physics in medicine and biology.

[120]  B E Sobel,et al.  Influence of Cardiac and Respiratory Motion on Tomographic Reconstructions of the Heart: Implications for Quantitative Nuclear Cardiology , 1982, Journal of computer assisted tomography.

[121]  M E Phelps,et al.  Quantitation in Positron Emission Computed Tomography: 6. Effect of Nonuniform Resolution , 1982, Journal of computer assisted tomography.

[122]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.