Construction of an efficacious model for a nondestructive identification of traditional Chinese medicines Liuwei Dihuang pills from different manufacturers using near-infrared spectroscopy and moving window partial least-squares discriminant analysis.

This paper reports on the construction of an efficacious model for a non-invasive identification of traditional Chinese medicines, Liuwei Dihuang pills from different manufacturers, on the basis of near-infrared spectra (NIRS) coupled with moving window partial least-squares discriminant analysis (MWPLSDA). Considering the continuity of near-infrared spectral measurements, MWPLSDA is used to identify continuous and highly classification-related information intervals, a simple, yet effective classification model that can be developed for identifying accurate 150 Liuwei Dihuang pills from five different manufacturers. Meanwhile, the method is compared with some traditional pattern-recognition methods including principal component analysis (PCA), linear discriminant analysis (LDA) and partial least-squares discriminant analysis (PLSDA). The obtained results show that the method not only can reduce the operation time, but also significantly improves the classification accuracy. Hence, the nondestructive method can be expected to be promising for more practical applications on quality control and the discrimination of traditional Chinese medicine.

[1]  E. K. Kemsley,et al.  Discriminant analysis of high-dimensional data: a comparison of principal components analysis and partial least squares data reduction methods , 1996 .

[2]  Young-Ah Woo,et al.  Near-infrared (NIR) spectroscopy for the non-destructive and fast determination of geographical origin of Angelicae gigantis Radix. , 2005, Journal of pharmaceutical and biomedical analysis.

[3]  Yukihiro Ozaki,et al.  Improvement of partial least squares models for in vitro and in vivo glucose quantifications by using near-infrared spectroscopy and searching combination moving window partial least squares , 2006 .

[4]  R. W. Lutz,et al.  Metabolic profiling of glucuronides in human urine by LC-MS/MS and partial least-squares discriminant analysis for classification and prediction of gender. , 2006, Analytical chemistry.

[5]  Jian-hui Jiang,et al.  Spectral regions selection to improve prediction ability of PLS models by changeable size moving window partial least squares and searching combination moving window partial least squares , 2004 .

[6]  Yukihiro Ozaki,et al.  Selective removal of interference signals for near-infrared spectra of biomedical samples by using region orthogonal signal correction , 2004 .

[7]  Hoeil Chung,et al.  Improving the robustness of a partial least squares (PLS) model based on pure component selectivity analysis and range optimization: case study for the analysis of an etching solution containing hydrogen peroxide. , 2006, Analytica chimica acta.

[8]  Magali Laasonen,et al.  Fast identification of Echinacea purpurea dried roots using near-infrared spectroscopy. , 2002, Analytical chemistry.

[9]  D B Kell,et al.  Variable selection in discriminant partial least-squares analysis. , 1998, Analytical chemistry.

[10]  Y. Ozaki,et al.  Applications of moving window two-dimensional correlation spectroscopy to analysis of phase transitions and spectra classification. , 2003, Analytical chemistry.

[11]  Yukihiro Ozaki,et al.  Near-infrared spectroscopic determination of human serum albumin, γ-globulin, and glucose in a control serum solution with searching combination moving window partial least squares , 2004 .

[12]  S. Wold,et al.  Wavelength interval selection in multicomponent spectral analysis by moving window partial least-squares regression with applications to mid-infrared and near-infrared spectroscopic data. , 2002, Analytical chemistry.

[13]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[14]  H. Martens,et al.  Light scattering and light absorbance separated by extended multiplicative signal correction. application to near-infrared transmission analysis of powder mixtures. , 2003, Analytical chemistry.

[15]  Hai-Long Wu,et al.  Moving Window Partial Least-Squares Discriminant Analysis for Identification of Different Kinds of Bezoar Samples by near Infrared Spectroscopy and Comparison of Different Pattern Recognition Methods , 2007 .

[16]  P. Jurs,et al.  Classification of multidrug-resistance reversal agents using structure-based descriptors and linear discriminant analysis. , 2000, Journal of medicinal chemistry.

[17]  Young-Ah Woo,et al.  Optimization of informative spectral regions for the quantification of cholesterol, glucose and urea in control serum solutions using searching combination moving window partial least squares regression method with near infrared spectroscopy , 2006 .