Visible-light optical coherence tomography: a review

Abstract. Visible-light optical coherence tomography (vis-OCT) is an emerging imaging modality, providing new capabilities in both anatomical and functional imaging of biological tissue. It relies on visible light illumination, whereas most commercial and investigational OCTs use near-infrared light. As a result, vis-OCT requires different considerations in engineering design and implementation but brings unique potential benefits to both fundamental research and clinical care of several diseases. Here, we intend to provide a summary of the development of vis-OCT and its demonstrated applications. We also provide perspectives on future technology improvement and applications.

[1]  Hao F. Zhang,et al.  Visible light optical coherence tomography measures retinal oxygen metabolic response to systemic oxygenation , 2015, Light: Science & Applications.

[2]  K.D. McDonald Applications and technology projections for GPS civil user equipment , 1992, IEEE PLANS 92 Position Location and Navigation Symposium Record.

[3]  Ji Yi,et al.  Monte Carlo Investigation of Optical Coherence Tomography Retinal Oximetry , 2015, IEEE Transactions on Biomedical Engineering.

[4]  Ji Yi,et al.  Analyzing absorption and scattering spectra of micro-scale structures with spectroscopic optical coherence tomography. , 2009, Optics express.

[5]  Shimin Zhao,et al.  Sirtinol promotes PEPCK1 degradation and inhibits gluconeogenesis by inhibiting deacetylase SIRT2 , 2017, Scientific Reports.

[6]  Shubjeet Kaur,et al.  Investigation of Noninvasive in vivo Blood Hematocrit Measurement Using NIR Reflectance Spectroscopy and Partial Least-Squares Regression , 2000 .

[7]  Leopold Schmetterer,et al.  Doppler Optical Coherence Tomography , 2014, Progress in Retinal and Eye Research.

[8]  Melissa A. Wilk,et al.  The Effect of Retinal Melanin on Optical Coherence Tomography Images , 2017, Translational vision science & technology.

[9]  Shanbao Tong,et al.  Imaging hemodynamic response after ischemic stroke in mouse cortex using visible-light optical coherence tomography. , 2016, Biomedical optics express.

[10]  Bo Wang,et al.  Adaptive optics optical coherence tomography in glaucoma , 2017, Progress in Retinal and Eye Research.

[11]  Carmen A. Puliafito,et al.  Depth-resolved rhodopsin molecular contrast imaging for functional assessment of photoreceptors , 2015, Scientific Reports.

[12]  C K Hitzenberger,et al.  Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography. , 2000, Optics letters.

[13]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[14]  Xiao Shu,et al.  Simultaneous optical coherence tomography angiography and fluorescein angiography in rodents with normal retina and laser-induced choroidal neovascularization. , 2015, Optics letters.

[15]  Jui-che Tsai,et al.  Dental Optical Coherence Tomography , 2013, Sensors.

[16]  Ji Yi,et al.  Dual-band optical coherence tomography using a single supercontinuum laser source , 2016, Journal of biomedical optics.

[17]  R. Spaide,et al.  Retinal vascular layers imaged by fluorescein angiography and optical coherence tomography angiography. , 2015, JAMA ophthalmology.

[18]  Adam Wax,et al.  Noise characterization of supercontinuum sources for low-coherence interferometry applications. , 2014, Journal of the Optical Society of America. A, Optics, image science, and vision.

[19]  Jianming Hu,et al.  Dual-band spectral-domain optical coherence tomography for in vivo imaging the spectral contrasts of the retinal nerve fiber layer , 2011, Optics express.

[20]  Maciej Wojtkowski,et al.  Spectral oximetry assessed with high-speed ultra-high-resolution optical coherence tomography. , 2007, Journal of biomedical optics.

[21]  Ji Yi,et al.  Visible-Light Optical Coherence Tomography Angiography for Monitoring Laser-Induced Choroidal Neovascularization in Mice , 2016, Investigative ophthalmology & visual science.

[22]  Orly Liba,et al.  Speckle-modulating optical coherence tomography in living mice and humans , 2017, Nature Communications.

[23]  Ji Yi,et al.  Imaging endocervical mucus anatomy and dynamics in macaque female reproductive track using optical coherence tomography. , 2015, Quantitative imaging in medicine and surgery.

[24]  Adolf Friedrich Fercher,et al.  Optical coherence tomography - development, principles, applications. , 2010, Zeitschrift fur medizinische Physik.

[25]  Xiao Shu,et al.  Spectroscopic Doppler analysis for visible-light optical coherence tomography , 2017, Journal of biomedical optics.

[26]  Angelika Unterhuber,et al.  Visible light optical coherence tomography , 2002, SPIE BiOS.

[27]  J. Schmitt,et al.  Differential absorption imaging with optical coherence tomography , 1998 .

[28]  Xiao Shu,et al.  Retinal oximetry in humans using visible-light optical coherence tomography [Invited]. , 2017, Biomedical optics express.

[29]  Christoph K. Hitzenberger,et al.  Spectroscopic imaging with spectral domain visible light optical coherence microscopy in Alzheimer’s disease brain samples , 2017, Biomedical optics express.

[30]  Lei Zhang,et al.  Oblique scanning laser microscopy for simultaneously volumetric structural and molecular imaging using only one raster scan , 2017, Scientific Reports.

[31]  Josh Wallman,et al.  The multifunctional choroid , 2010, Progress in Retinal and Eye Research.

[32]  Ci-Ling Pan,et al.  Ultrahigh-resolution optical coherence tomography at 1.3 μm central wavelength by using a supercontinuum source pumped by noise-like pulses , 2016 .

[33]  Nadia K. Waheed,et al.  Investigating the choriocapillaris and choroidal vasculature with new optical coherence tomography technologies , 2016, Progress in Retinal and Eye Research.

[34]  Xiang-Run Huang,et al.  Reflectance decreases before thickness changes in the retinal nerve fiber layer in glaucomatous retinas. , 2011, Investigative ophthalmology & visual science.

[35]  Lasse Leick,et al.  Single all-fiber-based nanosecond-pulsed supercontinuum source for multispectral photoacoustic microscopy and optical coherence tomography. , 2016, Optics letters.

[36]  Shau Poh Chong,et al.  Optical coherence imaging of microvascular oxygenation and hemodynamics , 2014, 2014 Conference on Lasers and Electro-Optics (CLEO) - Laser Science to Photonic Applications.

[37]  A F Fercher,et al.  Optical coherence tomography. , 1996, Journal of biomedical optics.

[38]  Ton G van Leeuwen,et al.  Light absorption of (oxy-)hemoglobin assessed by spectroscopic optical coherence tomography. , 2003, Optics letters.

[39]  Ton G van Leeuwen,et al.  Volumetric in vivo visualization of upper urinary tract tumors using optical coherence tomography: a pilot study. , 2013, The Journal of urology.

[40]  Daniel L Marks,et al.  Near-infrared dyes as contrast-enhancing agents for spectroscopic optical coherence tomography. , 2004, Optics letters.

[41]  Ole Bang,et al.  High energy supercontinuum sources using tapered photonic crystal fibers for multispectral photoacoustic microscopy , 2016, Journal of biomedical optics.

[42]  Shau Poh Chong,et al.  Structural and functional human retinal imaging with a fiber-based visible light OCT ophthalmoscope. , 2017, Biomedical optics express.

[43]  Francisco E. Robles,et al.  Molecular imaging true-colour spectroscopic optical coherence tomography. , 2011, Nature photonics.

[44]  Ji Yi,et al.  Human retinal imaging using visible-light optical coherence tomography guided by scanning laser ophthalmoscopy. , 2015, Biomedical optics express.

[45]  Francisco E. Robles,et al.  Assessing hemoglobin concentration using spectroscopic optical coherence tomography for feasibility of tissue diagnostics , 2010, Biomedical optics express.

[46]  Shuliang Jiao Simultaneous optical coherence tomography and autofluorescence microscopy with a single light source , 2013 .

[47]  Julia Welzel,et al.  Optical coherence tomography in dermatology , 2013, Journal of biomedical optics.

[48]  Wolfgang Wieser,et al.  Megahertz FDML laser with up to 143nm sweep range for ultrahigh resolution OCT at 1050nm , 2016, SPIE BiOS.

[49]  Shuliang Jiao,et al.  Visible-light optical coherence tomography-based multimodal retinal imaging for improvement of fluorescent intensity quantification. , 2016, Biomedical optics express.

[50]  Srinivas R. Sadda,et al.  Swept-Source Optical Coherence Tomography , 2017 .

[51]  Ton G van Leeuwen,et al.  Quantitative comparison of analysis methods for spectroscopic optical coherence tomography. , 2013, Biomedical optics express.

[52]  Ruikang K. Wang,et al.  Ultralong-range optical coherence tomography-based angiography by akinetic swept source , 2017, BiOS.

[53]  Shuliang Jiao,et al.  Accuracy of retinal oximetry: a Monte Carlo investigation , 2013, Journal of biomedical optics.

[54]  R. Dhillon,et al.  For the safe use of lasers , 1989 .

[55]  Hao F. Zhang,et al.  Real-time Functional Analysis of Inertial Microfluidic Devices via Spectral Domain Optical Coherence Tomography , 2016, Scientific Reports.

[56]  Hao Li,et al.  Quantifying melanin concentration in retinal pigment epithelium using broadband photoacoustic microscopy. , 2017, Biomedical optics express.

[57]  Masanobu Miura,et al.  Optical coherence tomography is superior to intravascular ultrasound for diagnosis of distal-type chronic thromboembolic pulmonary hypertension. , 2013, Circulation journal : official journal of the Japanese Circulation Society.

[58]  Kazuo Tsubota,et al.  Effects of blue light on the circadian system and eye physiology , 2016, Molecular vision.

[59]  Dirk J. Faber,et al.  A literature review and novel theoretical approach on the optical properties of whole blood , 2013, Lasers in Medical Science.

[60]  Dietrich Schweitzer,et al.  Diabetic patients with retinopathy show increased retinal venous oxygen saturation , 2009, Graefe's Archive for Clinical and Experimental Ophthalmology.

[61]  Dirk J. Faber,et al.  Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography. , 2005 .

[62]  Shau Poh Chong,et al.  Cerebral metabolic rate of oxygen (CMRO2) assessed by combined Doppler and spectroscopic OCT. , 2015, Biomedical optics express.

[63]  Stephen J. Matcher,et al.  Visible-light OCT spectrometer for microvascular oximetry , 2008, SPIE BiOS.

[64]  Kate Grieve,et al.  Large Field, High Resolution Full-Field Optical Coherence Tomography , 2014, Technology in cancer research & treatment.

[65]  Ruikang K. Wang,et al.  Theory, developments and applications of optical coherence tomography , 2005 .

[66]  Ji Yi,et al.  Visible-light optical coherence tomography for retinal oximetry. , 2013, Optics letters.

[67]  Ji Yi,et al.  Inner retinal oxygen metabolism in the 50/10 oxygen-induced retinopathy model , 2015, Scientific Reports.

[68]  Ji Yi,et al.  In vivo functional microangiography by visible-light optical coherence tomography. , 2014, Biomedical optics express.

[69]  Adam Wax,et al.  In vivo analysis of burns in a mouse model using spectroscopic optical coherence tomography. , 2014, Optics letters.

[70]  Shuliang Jiao,et al.  Simultaneous optical coherence tomography and lipofuscin autofluorescence imaging of the retina with a single broadband light source at 480nm. , 2014, Biomedical optics express.

[71]  Amani A. Fawzi,et al.  OCT angiography and visible-light OCT in diabetic retinopathy , 2017, Vision Research.

[72]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[73]  Kang Zhang,et al.  Spectroscopic-speckle variance OCT for microvasculature detection and analysis , 2011, Biomedical optics express.

[74]  A. Bird,et al.  FUNDUS AUTOFLUORESCENCE IMAGING: Review and Perspectives , 2008, Retina.

[75]  William J. Brown,et al.  Functional optical coherence tomography: principles and progress , 2015, Physics in medicine and biology.

[76]  M. V. van Gemert,et al.  Two-dimensional birefringence imaging in biological tissue using polarization-sensitive optical coherence tomography , 1997, European Conference on Biomedical Optics.

[77]  Ji Yi,et al.  Theoretical model for optical oximetry at the capillary level: exploring hemoglobin oxygen saturation through backscattering of single red blood cells , 2017, Journal of biomedical optics.

[78]  Graham Wild,et al.  Characterizing the resolvability of real superluminescent diode sources for application to optical coherence tomography using a low coherence interferometry model , 2014, Journal of biomedical optics.

[79]  Ji Yi,et al.  Measuring oxygen saturation in retinal and choroidal circulations in rats using visible light optical coherence tomography angiography. , 2015, Biomedical optics express.

[80]  Xiao Shu,et al.  Optical coherence tomography angiography of retinal vascular occlusions produced by imaging-guided laser photocoagulation. , 2017, Biomedical optics express.

[81]  Shau Poh Chong,et al.  Quantitative Microvascular Hemoglobin Mapping Using Visible Light Spectroscopic Optical Coherence Tomography References and Links , 2022 .

[82]  Ji Yi,et al.  Estimation of oxygen saturation from erythrocytes by high-resolution spectroscopic optical coherence tomography. , 2010, Optics letters.

[83]  Sina Farsiu,et al.  Wide-field retinal optical coherence tomography with wavefront sensorless adaptive optics for enhanced imaging of targeted regions. , 2017, Biomedical optics express.

[84]  L. Schmetterer,et al.  Ultrahigh-resolution OCT imaging of the human cornea. , 2017, Biomedical optics express.

[85]  Shau Poh Chong,et al.  Optical coherence imaging of hemodynamics, metabolism, and cell viability during brain injury , 2014, 2014 Conference on Lasers and Electro-Optics (CLEO) - Laser Science to Photonic Applications.

[86]  R. Knighton,et al.  Directional and spectral reflectance of the rat retinal nerve fiber layer. , 1999, Investigative ophthalmology & visual science.

[87]  Einar Stefánsson,et al.  Retinal oxygen saturation is altered in diabetic retinopathy , 2011, British Journal of Ophthalmology.

[88]  Ji Yi,et al.  Increased Retinal Oxygen Metabolism Precedes Microvascular Alterations in Type 1 Diabetic Mice , 2017, Investigative ophthalmology & visual science.

[89]  Wenzhong Liu,et al.  Monte Carlo investigation on quantifying the retinal pigment epithelium melanin concentration by photoacoustic ophthalmoscopy , 2015, Journal of biomedical optics.

[90]  David H Sliney,et al.  Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[91]  Guillermo J Tearney,et al.  Depth resolved detection of lipid using spectroscopic optical coherence tomography. , 2013, Biomedical optics express.

[92]  Ji Yi,et al.  Optical Detection of Early Damage in Retinal Ganglion Cells in a Mouse Model of Partial Optic Nerve Crush Injury , 2016, Investigative ophthalmology & visual science.

[93]  Martin F. Kraus,et al.  Quantitative optical coherence tomography angiography of choroidal neovascularization in age-related macular degeneration. , 2014, Ophthalmology.

[94]  Shanbao Tong,et al.  Monitoring Acute Stroke in Mouse Model Using Laser Speckle Imaging-Guided Visible-Light Optical Coherence Tomography , 2018, IEEE Transactions on Biomedical Engineering.

[95]  Wenzhong Liu,et al.  Colposcopic imaging using visible-light optical coherence tomography , 2017, Journal of biomedical optics.

[96]  J. Fujimoto,et al.  Spectroscopic optical coherence tomography. , 2000 .