Performance and work capacity of a polypyrrole conducting polymer linear actuator

Abstract This paper reports a performance analysis of a conducting polymer film actuator made of polypyrrole (PPy). Electrochemomechanical characterizations of the active displacement and the developed force of a PPy free-standing film at different loading conditions are performed. Two driving signals are used: the former, a cyclic voltammetry at 1 mV/s between ± 1 V, is used to carry out an accurate on-line analysis of the film displacement; the latter, a current square wave between 0.02 and 0.1 Hz, is helpful for evaluating the effectiveness of the actuator in terms both of actuation strain and of developed force. The experimental results indicate that 1 % displacement, 3 MPa force and working density of 73 kJ/m3 are achievable goals for a conducting polymer linear actuator, which are interesting results if compared with the limiting specifications of skeletal muscle. Additionally, two different approaches to the electrochemomechanical modeling of the conducting polymerfluid electrolyte system are illustrated, together with a discussion about foreseen improvements in the implementation of actuating structures.

[1]  M. Biot General Theory of Three‐Dimensional Consolidation , 1941 .

[2]  C. Hsu,et al.  Polyaniline spinning solutions and fibers , 1993 .

[3]  R. V. Gregory,et al.  Improved solution stability and spinnability of concentrated polyaniline solutions using N,N′-dimethyl propylene urea as the spin bath solvent , 1995 .

[4]  A. MacDiarmid,et al.  Artificial muscle: electromechanical actuators using polyaniline films , 1994 .

[5]  Geoffrey M. Spinks,et al.  Mechanism of electromechanical actuation in polypyrrole , 1995 .

[6]  D. Rossi,et al.  Characterization and modelling of a conducting polymer muscle-like linear actuator , 1997 .

[7]  P J Basser,et al.  The dynamics of a hydrogel strip. , 1992, Biorheology.

[8]  Toribio F. Otero,et al.  Artificial muscles from bilayer structures , 1993 .

[9]  R. Baughman Conducting polymer artificial muscles , 1996 .

[10]  P. Mazur,et al.  Non-equilibrium thermodynamics, , 1963 .

[11]  D. De Rossi,et al.  Passive mechanical properties of polypyrrole films: a continuum, poroelastic model , 1997 .

[12]  Charles Becht,et al.  Micro Electromechanical Actuators Based on Conducting Polymers , 1991 .

[13]  D. De Rossi,et al.  Steerable Microcatheters Actuated by Embedded Conducting Polymer Structures , 1996 .

[14]  E. Smela,et al.  Controlled Folding of Micrometer-Size Structures , 1995, Science.

[15]  Paolo Dario,et al.  Microactuators for microrobots: a critical survey , 1992 .

[16]  Q. Pei,et al.  Bending bilayer strips built from polyaniline for artificial electrochemical muscles , 1993 .

[17]  P. Morasso,et al.  Pseudomuscular Gel Actuators for Advanced Robotics , 1992 .

[18]  D. de Rossi,et al.  Actuation Properties of Electrochemically Driven Polypyrrole Free-Standing Films , 1995 .