A new technique for islanding detection using voltage phase angle of inverter-based DGs

Abstract In this paper, a new method is studied for the islanding detection of an inverter based distribution generation. The use of parameters at PCC (such as deviation of the voltage and frequency) as a feedback has been considered by researchers. The variation of voltage angle is used as a feedback in the proposed method. After an islanding occurrence the variation of voltage phase angle can change the references of active and reactive powers. The power variations cause the voltage and frequency deviations as detection parameters. The performance of islanding detection of the proposed method is investigated under the IEEE UL 1741 for the worst-case. The simulation results show that the adverse effects of this method are negligible and non-detection zone of the proposed method is small. Also, this method has no significant effects on the power quality and system normal operation mode. In addition, the results of tests for multiple DGs are suitable and there is not any significant interference between DGs in the normal operation mode.

[1]  Pradipta Kishore Dash,et al.  A hybrid time–frequency approach based fuzzy logic system for power island detection in grid connected distributed generation , 2012 .

[2]  H.H. Zeineldin,et al.  A $Q$– $f$ Droop Curve for Facilitating Islanding Detection of Inverter-Based Distributed Generation , 2009, IEEE Transactions on Power Electronics.

[3]  Hurng-Liahng Jou,et al.  Active islanding detection method for inverter-based distribution generation power system , 2012 .

[4]  Mikihiko Matsui,et al.  Modeling and design of phase shift anti-islanding method using non-detection zone , 2007 .

[5]  M. B. Brennen,et al.  Vector analysis and control of advanced static VAr compensators , 1991 .

[6]  J.L. Kirtley,et al.  A Simple Technique for Islanding Detection With Negligible Nondetection Zone , 2009, IEEE Transactions on Power Delivery.

[7]  Shyh-Jier Huang,et al.  Enhancement of islanding-detection of distributed generation systems via wavelet transform-based approaches , 2008 .

[8]  W. Bower,et al.  Evaluation of Islanding Detection Methods for Utility-Interactive Inverters in Photovoltaic Systems , 2002 .

[9]  Jong-Yul Kim,et al.  Voltage Shift Acceleration Control for Anti-Islanding of Distributed Generation Inverters , 2011, IEEE Transactions on Power Delivery.

[10]  Wei Lee Woon,et al.  A Bayesian Passive Islanding Detection Method for Inverter-Based Distributed Generation Using ESPRIT , 2011, IEEE Transactions on Power Delivery.

[11]  R. Iravani,et al.  Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit , 2008, IEEE Transactions on Power Electronics.

[12]  Walmir Freitas,et al.  Formulas for predicting the dynamic performance of ROCOF relays for embedded generation applications , 2006 .

[13]  Russell H. Bonn,et al.  Development and Testing of an Approach to Anti-Islanding in Utility-Interconnected Photovoltaic Systems , 2000 .

[14]  Miles A Redfern,et al.  Protection against loss of utility grid supply for a dispersed storage and generation unit , 1993 .

[15]  Ehab F. El-Saadany,et al.  Impact of DG interface control on islanding detection and nondetection zones , 2006 .

[16]  R Iravani,et al.  Nondetection Zone Assessment of an Active Islanding Detection Method and its Experimental Evaluation , 2011, IEEE Transactions on Power Delivery.

[17]  M.H. Nehrir,et al.  A Hybrid Islanding Detection Technique Using Voltage Unbalance and Frequency Set Point , 2007, IEEE Transactions on Power Systems.

[18]  Ronnie Belmans,et al.  Testing the islanding protection function of photovoltaic inverters , 2003 .

[19]  A. H. K. Alaboudy,et al.  Islanding Detection for Inverter-Based DG Coupled With Frequency-Dependent Static Loads , 2011, IEEE Transactions on Power Delivery.

[20]  Ajeet Rohatgi,et al.  Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones , 2000 .

[21]  L.A.C. Lopes,et al.  Performance assessment of active frequency drifting islanding detection methods , 2006, IEEE Transactions on Energy Conversion.

[22]  Noradin Ghadimi,et al.  Islanding detection for inverter-based DG coupled with using an adaptive neuro-fuzzy inference system , 2013 .