High-throughput biological small-angle X-ray scattering with a robotically loaded capillary cell.

With the rise in popularity of biological small-angle X-ray scattering (BioSAXS) measurements, synchrotron beamlines are confronted with an ever-increasing number of samples from a wide range of solution conditions. To meet these demands, an increasing number of beamlines worldwide have begun to provide automated liquid-handling systems for sample loading. This article presents an automated sample-loading system for BioSAXS beamlines, which combines single-channel disposable-tip pipetting with a vacuum-enclosed temperature-controlled capillary flow cell. The design incorporates an easily changeable capillary to reduce the incidence of X-ray window fouling and cross contamination. Both the robot-control and the data-processing systems are written in Python. The data-processing code, RAW, has been enhanced with several new features to form a user-friendly BioSAXS pipeline for the robot. The flow cell also supports efficient manual loading and sample recovery. An effective rinse protocol for the sample cell is developed and tested. Fluid dynamics within the sample capillary reveals a vortex ring pattern of circulation that redistributes radiation-damaged material. Radiation damage is most severe in the boundary layer near the capillary surface. At typical flow speeds, capillaries below 2 mm in diameter are beginning to enter the Stokes (creeping flow) regime in which mixing due to oscillation is limited. Analysis within this regime shows that single-pass exposure and multiple-pass exposure of a sample plug are functionally the same with regard to exposed volume when plug motion reversal is slow. The robot was tested on three different beamlines at the Cornell High-Energy Synchrotron Source, with a variety of detectors and beam characteristics, and it has been used successfully in several published studies as well as in two introductory short courses on basic BioSAXS methods.

[1]  Jörg P Kutter,et al.  High-throughput small angle X-ray scattering from proteins in solution using a microfluidic front-end. , 2008, Analytical chemistry.

[2]  B. Zoltowski,et al.  Time-resolved dimerization of a PAS-LOV protein measured with photocoupled small angle X-ray scattering. , 2008, Journal of the American Chemical Society.

[3]  G. David,et al.  Combined sampler robot and high-performance liquid chromatography: a fully automated system for biological small-angle X-ray scattering experiments at the Synchrotron SOLEIL SWING beamline , 2009 .

[4]  W. Deen Analysis Of Transport Phenomena , 1998 .

[5]  Hideki Fujioka,et al.  Steady propagation of a liquid plug in a two-dimensional channel. , 2004, Journal of biomechanical engineering.

[6]  M. Fenstermacher,et al.  First tests of molybdenum mirrors for ITER diagnostics in DIII-D divertor , 2006 .

[7]  J. S. Vrentas,et al.  Steady flow in the region of closed streamlines in a cylindrical cavity , 1971, Journal of Fluid Mechanics.

[8]  H. Sondermann,et al.  Structural basis for the nucleotide-dependent dimerization of the large G protein atlastin-1/SPG3A , 2011, Proceedings of the National Academy of Sciences.

[9]  John Kuriyan,et al.  SAXS and the working protein. , 2005, Structure.

[10]  T. N. Bhat,et al.  The Protein Data Bank , 2000, Nucleic Acids Res..

[11]  Nick Menhart,et al.  Liquid-chromatography-coupled SAXS for accurate sizing of aggregating proteins. , 2004, Journal of synchrotron radiation.

[12]  O. Glatter,et al.  19 – Small-Angle X-ray Scattering , 1973 .

[13]  Robin L. Owen,et al.  Determination of X-ray flux using silicon pin diodes , 2009, Journal of synchrotron radiation.

[14]  M. Fritsche,et al.  Automated sample-changing robot for solution scattering experiments at the EMBL Hamburg SAXS station X33 , 2008, Journal of applied crystallography.

[15]  M. Kozak,et al.  Glucose isomerase from Streptomyces rubiginosus– potential molecular weight standard for small-angle X-ray scattering , 2005 .

[16]  R. Hayashi,et al.  Conformational strictness required for maximum activity and stability of bovine pancreatic ribonuclease A as revealed by crystallographic study of three Phe120 mutants at 1.4 Å resolution , 2002, Protein science : a publication of the Protein Society.

[17]  Jill Trewhella,et al.  Small‐angle scattering for structural biology—Expanding the frontier while avoiding the pitfalls , 2010, Protein science : a publication of the Protein Society.

[18]  S. Doniach,et al.  Time-resolved X-ray scattering and RNA folding. , 2009, Methods in enzymology.

[19]  Lise Arleth,et al.  Automated microfluidic sample-preparation platform for high-throughput structural investigation of proteins by small-angle X-ray scattering , 2011 .

[20]  Adam Round,et al.  New beamline dedicated to solution scattering from biological macromolecules at the ESRF , 2010 .

[21]  B. Hsiao,et al.  A laser-aided prealigned pinhole collimator for synchrotron x rays , 1994 .

[22]  Dmitri I. Svergun,et al.  Accuracy of molecular mass determination of proteins in solution by small-angle X-ray scattering , 2007 .

[23]  Peter V. Konarev,et al.  ATSAS 2.1 – towards automated and web-supported small-angle scattering data analysis , 2007 .

[24]  John A. Tainer,et al.  Robust, high-throughput solution structural analyses by small angle X-ray scattering (SAXS) , 2009, Nature Methods.

[25]  H. Stuhrmann The use of X-ray synchrotron radiation for structural research in biology , 1978, Quarterly Reviews of Biophysics.

[26]  D. Svergun,et al.  CRYSOL : a program to evaluate X-ray solution scattering of biological macromolecules from atomic coordinates , 1995 .

[27]  Z. Dauter,et al.  SAD manganese in two crystal forms of glucose isomerase. , 2003, Acta crystallographica. Section D, Biological crystallography.

[28]  I. Millett,et al.  Sample holder for small-angle x-ray scattering static and flow cell measurements , 2006 .

[29]  P. Vachette,et al.  Improved Signal-to-Background Ratio in Small-Angle X-ray Scattering Experiments with Synchrotron Radiation using an Evacuated Cell for Solutions , 1997 .

[30]  R. Gillilan,et al.  X-ray crystal structure and small-angle X-ray scattering of sheep liver sorbitol dehydrogenase. , 2011, Acta crystallographica. Section D, Biological crystallography.

[31]  D. Castner,et al.  Biomedical surface science: Foundations to frontiers , 2002 .

[32]  A. Guinier 30 years of small‐angle x‐ray scattering , 1969 .

[33]  E. Eikenberry,et al.  Charge-coupled device area x-ray detectors , 2002 .

[34]  D. Carter,et al.  The atomic structure of human methemalbumin at 1.9 A. , 2002, Biochemical and biophysical research communications.

[35]  Michael Krumrey,et al.  High-accuracy detector calibration at the PTB four-crystal monochromator beamline , 2001 .