Atmospheric-operable bioactuator powered by insect muscle packaged with medium.

Despite attempts in a number of studies to utilize muscle tissue and cells as microactuators, all of the biohybrid microdevices have been operable only in the culture medium and none have worked in air due to the dry environment. This paper demonstrates an atmospheric-operable bioactuator (AOB) fabricated by packaging an insect dorsal vessel (DV) tissue with a small amount of culture medium inside a capsule. The AOB, consisting of microtweezers and the capsule, was designed based on a structural simulation that took into account the capillary effect. The base part of the microtweezers was deformed by spontaneous contractions of the DV tissue in the medium inside the capsule, by which the front edges of the microtweezer arms projecting above the medium surface were also deformed. First, we confirmed in the medium that the DV tissue was able to reduce the gap between the arm tips of the microtweezers. After taking the AOB out of the medium, as we expected, the AOB continued to work in air at room temperature. The gap reduction in air became larger than the one in the medium due to a surface tension effect, which was consistent with the simulation findings on the surface tension by the phase-field method. Second, we demonstrated that the AOB deformed a thin-wall ring placed between its tips in air. Third, we measured the lifetime of the AOB. The AOB kept working for around 40 minutes in air, but eventually stopped due to medium evaporation. As the evaporation progressed, the microtweezers were pressed onto the capsule wall by the surface tension and opening and closing stopped. Finally, we attempted to prevent the medium from evaporating by pouring liquid paraffin (l-paraffin) over the medium after lipophilic coating of the capsule. As a result, we succeeded in prolonging the AOB lifetime to more than five days. In this study, we demonstrated the significant potential of insect muscle tissue and cells as a bioactuator in air and at room temperature. By integrating insect tissue and cells not only into a microspace but also onto a substrate, we expect to realize a biohybrid MEMS device with various functions in the near future.

[1]  Ron Weiss,et al.  Formation and optogenetic control of engineered 3D skeletal muscle bioactuators. , 2012, Lab on a chip.

[2]  W. Kou,et al.  Induction of ventricular arrhythmia by high and low osmolarity ionic and nonionic contrast media. , 1989, American heart journal.

[3]  Y. Akiyama,et al.  Room Temperature Operable Autonomously Moving Bio-Microrobot Powered by Insect Dorsal Vessel Tissue , 2012, PloS one.

[4]  Yuichi Hiratsuka,et al.  A microrotary motor powered by bacteria , 2006, Proceedings of the National Academy of Sciences.

[5]  L. Mahadevan,et al.  The “Cheerios effect” , 2005 .

[6]  G. Skjåk-Bræk,et al.  Alginate as immobilization matrix for cells. , 1990, Trends in biotechnology.

[7]  Keisuke Morishima,et al.  Culture of insect cells contracting spontaneously; research moving toward an environmentally robust hybrid robotic system. , 2008, Journal of biotechnology.

[8]  Keisuke Morishima,et al.  Electrical stimulation of cultured lepidopteran dorsal vessel tissue: an experiment for development of bioactuators , 2010, In Vitro Cellular & Developmental Biology - Animal.

[9]  Takehiko Kitamori,et al.  Biological cells on microchips: new technologies and applications. , 2007, Biosensors & bioelectronics.

[10]  Young Ho Seo,et al.  Analysis of Circular PDMS Microballoons With Ultralarge Deflection for MEMS Design , 2010, Journal of Microelectromechanical Systems.

[11]  George M. Whitesides,et al.  Modeling of Menisci and Capillary Forces from the Millimeter to the Micrometer Size Range , 2001 .

[12]  Henry Hess,et al.  Engineering applications of biomolecular motors. , 2011, Annual review of biomedical engineering.

[13]  G. Whitesides,et al.  Microoxen: microorganisms to move microscale loads. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[14]  D. M. Anderson,et al.  DIFFUSE-INTERFACE METHODS IN FLUID MECHANICS , 1997 .

[15]  Vikramaditya G. Yadav,et al.  Cell and protein compatibility of parylene-C surfaces. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[16]  D. Bodas,et al.  Hydrophilization and hydrophobic recovery of PDMS by oxygen plasma and chemical treatment—An SEM investigation , 2007 .

[17]  Takehiko Kitamori,et al.  An actuated pump on-chip powered by cultured cardiomyocytes. , 2006, Lab on a chip.

[18]  Keisuke Morishima,et al.  Long-term and room temperature operable bioactuator powered by insect dorsal vessel tissue. , 2009, Lab on a chip.

[19]  Takehiko Kitamori,et al.  Demonstration of a bio-microactuator powered by cultured cardiomyocytes coupled to hydrogel micropillars , 2006 .

[20]  W. Kraus,et al.  Endothelial, cardiac muscle and skeletal muscle exhibit different viscous and elastic properties as determined by atomic force microscopy. , 2001, Journal of biomechanics.

[21]  K. Kiguchi,et al.  A physiological saline for lepidopterous insects: Effects of ionic composition on heart beat and neuromuscular transmission , 1995 .

[22]  A. Huxley,et al.  The variation in isometric tension with sarcomere length in vertebrate muscle fibres , 1966, The Journal of physiology.

[23]  Y. Akiyama,et al.  Rapidly-moving insect muscle-powered microrobot and its chemical acceleration , 2012, Biomedical microdevices.

[24]  J. Xi,et al.  Self-assembled microdevices driven by muscle , 2005, Nature materials.

[25]  Megan L. McCain,et al.  A tissue-engineered jellyfish with biomimetic propulsion , 2012, Nature Biotechnology.

[26]  G. Whitesides,et al.  Muscular Thin Films for Building Actuators and Powering Devices , 2007, Science.

[27]  Keisuke Morishima,et al.  Multi-scale reconstruction and performance of insect muscle powered bioactuator from tissue to cell sheet , 2010, 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[28]  Byungkyu Kim,et al.  Establishment of a fabrication method for a long-term actuated hybrid cell robot. , 2007, Lab on a chip.

[29]  Filip Ilievski,et al.  Soft robotics for chemists. , 2011, Angewandte Chemie.

[30]  Takehiko Kitamori,et al.  Demonstration of a PDMS-based bio-microactuator using cultured cardiomyocytes to drive polymer micropillars. , 2006, Lab on a chip.

[31]  Jérémy Streque,et al.  New Magnetic Microactuator Design Based on PDMS Elastomer and MEMS Technologies for Tactile Display , 2010, IEEE Transactions on Haptics.

[32]  G. Barbosa‐Cánovas,et al.  Alginate–calcium films: Water vapor permeability and mechanical properties as affected by plasticizer and relative humidity , 2008 .