Power management of a photovoltaic/battery pumping system in agricultural experiment station

Abstract This paper focuses on dynamic modeling, simulation, control and energy management in an agricultural experiment station located at Sahline–Tunisia consisting of a 1.5 kW photovoltaic panel (PV) and a 25 A h Lead Acid battery storage supplying an induction motor coupled to a centrifugal pump as mechanical load. The cost-optimally design and the new suitable power management approach are the two main objectives. An iterative optimization approach namely, the Deficiency of Power Supply Probability (DPSP), the Relative Excess Power Generated (REPG), the Energy Cost (EC) as well as the Total Net Present Cost (TNPC) have been developed in order to find the optimal configuration of PV/battery. To reach the second object, three new supervisory controllers are designed, a neuro-fuzzy controller, a fuzzy controller and an algorithm controller. In order to show the effectiveness of the first one, a comparison of the three controllers is proposed. The principal objectives of the three supervisory controllers are: (i) the design of an adequate tracking system maximum power point (MPPT) to extract the maximum power which is given by the theory of conservation of energy, (ii) the insurance of the control speed needed for the vectorial control of the induction motor, (iii) the regulation of the water in the tank which is taken as a second storage system and finally (iv) the insurance of the correct operation for all the conversion string in order to optimize the quantity of water pumped.

[1]  Chokri Ben Salah,et al.  Energy management of a hybrid photovoltaic system , 2012 .

[2]  John K. Kaldellis,et al.  Optimum sizing of photovoltaic-energy storage systems for autonomous small islands , 2010 .

[3]  S. I. Seleme,et al.  Efficiency optimization in stand-alone photovoltaic pumping system , 2012 .

[4]  K. Meah,et al.  Solar photovoltaic water pumping for remote locations , 2008 .

[5]  Byron A. Neal,et al.  Analysis of off-grid hybrid wind turbine/solar PV water pumping systems , 2012 .

[6]  Djamila Diaf,et al.  A methodology for optimal sizing of autonomous hybrid PV/wind system , 2007 .

[7]  Chokri Ben Salah,et al.  Comparison of fuzzy logic and neural network in maximum power point tracker for PV systems , 2011 .

[8]  W. G. Hurley,et al.  Optimisation of a photovoltaic battery ultracapacitor hybrid energy storage system , 2012 .

[9]  Mohamed Faouzi Mimouni,et al.  New methodology of speed-control of photovoltaic pumping system , 2013 .

[10]  Christian-Simon Ernst,et al.  Battery sizing for serial plug-in hybrid electric vehicles: A model-based economic analysis for Germany , 2011 .

[11]  A. Midoun,et al.  Control of a DC/DC converter by fuzzy controller for a solar pumping system , 2011 .

[12]  Seddik Bacha,et al.  Sizing stand-alone photovoltaic–wind hybrid system: Techno-economic analysis and optimization , 2014 .

[13]  Anis Sakly,et al.  Comparison between conventional methods and GA approach for maximum power point tracking of shaded solar PV generators , 2013 .

[14]  M. F. Mimouni,et al.  Commande et analyse des performances d'une station de pompage photovoltaïque fonctionnant en régime optimal , 2008 .

[15]  A. Hamidat,et al.  Systematic procedures for sizing photovoltaic pumping system, using water tank storage , 2009 .

[16]  A. Hamidat,et al.  Small-scale irrigation with photovoltaic water pumping system in Sahara regions , 2003 .

[17]  Hegazy Rezk,et al.  Sizing of a stand alone concentrated photovoltaic system in Egyptian site , 2013 .

[18]  M. F. Mimouni,et al.  Vectorial command of an asynchronous motor fed by a photovoltaic generator , 2004 .

[19]  Nelson A. Kelly,et al.  Solar photovoltaic charging of lithium-ion batteries , 2010 .

[20]  Maher Chaabene,et al.  Multi-criteria fuzzy algorithm for energy management of a domestic photovoltaic panel , 2008 .

[21]  Jure Margeta,et al.  A model for optimal sizing of photovoltaic irrigation water pumping systems , 2007 .

[22]  Rachid Ibtiouen,et al.  Techno-economic valuation and optimization of integrated photovoltaic/wind energy conversion system , 2011 .

[23]  Pr Djamila Rekioua Optimization of Photovoltaic Power Systems , 2012 .

[24]  Santanu Bandyopadhyay,et al.  Optimum sizing of wind-battery systems incorporating resource uncertainty , 2010 .

[25]  N. Nimpitiwan,et al.  Optimal sizing of photovoltaic distributed generators in a distribution system with consideration of solar radiation and harmonic distortion , 2012 .

[26]  A. Kaabeche,et al.  Techno-economic optimization of hybrid photovoltaic/wind/diesel/battery generation in a stand-alone power system , 2014 .

[27]  Robert Fuller,et al.  Sizing solar home systems for optimal development impact , 2012 .

[28]  Kostas Kalaitzakis,et al.  Methodology for optimal sizing of stand-alone photovoltaic/wind-generator systems using genetic algorithms , 2006 .

[29]  Stavros A. Papathanassiou,et al.  Optimum sizing of wind-pumped-storage hybrid power stations in island systems , 2014 .

[30]  John K. Kaldellis,et al.  Optimum wind- and photovoltaic-based stand-alone systems on the basis of life cycle energy analysis , 2012 .

[31]  C. Weber,et al.  Efficient Storage Capacity in Power Systems with Thermal and Renewable Generation , 2011 .

[32]  Akbar Maleki,et al.  Comparative study of artificial intelligence techniques for sizing of a hydrogen-based stand-alone photovoltaic/wind hybrid system , 2014 .

[33]  B. Bouzidi,et al.  Viability of solar or wind for water pumping systems in the Algerian Sahara regions – case study Adrar , 2011 .

[34]  Raúl Sarrias,et al.  Coordinate operation of power sources in a doubly-fed induction generator wind turbine/battery hybrid power system , 2012 .

[35]  Brian Norton,et al.  Economic viability of photovoltaic water pumping systems , 2006 .