Design Optimization of a Minimally Invasive Surgical Robot

The configuration of robot, the workspace analysis and optimization arc critical issues in robot manipulator design. The selection of structural parameters of a robot has a great influence on its workspace. The workspace is an important evaluating indicator. Based on the structure of the robot, the workspace is presented, and a mathematical model of optimum design of structural parameters of medical robot is set up with the workspace as an important constraint condition and configuration compact and the minimum weight as the objective function. A method is developed to solve the optimal value of structural parameters of the medical robot on condition that the requirement of the workspace is satisfied. This paper designs a radio frequency ablation medical robot system assisting surgeons effective treatment for patients with liver tumors. Surgery space, clinical operation requirements and optimize mechanical structure of robots requirement, are the key factors in designing a perfectly performing medical robot structure which is suitable for surgeons in their operation environment. The development of this medical robot system contributes to the promotion and popularization of the minimal invasive surgery.

[1]  Arthur E. Quaid,et al.  Haptic information displays for computer-assisted surgery , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[2]  Russell H. Taylor,et al.  Constrained Cartesian motion control for teleoperated surgical robots , 1996, IEEE Trans. Robotics Autom..

[3]  D. Stoianovici Robotic surgery , 2000, World Journal of Urology.

[4]  Li-Chun T. Wang,et al.  Extreme reaches and reachable workspace analysis of general parallel robotic manipulators , 1998, J. Field Robotics.

[5]  Martin Boerner,et al.  EUROPEAN EXPERIENCE WITH AN OPERATIVE ROBOT FOR PRIMARY AND REVISION TOTAL HIP – A SUMMARY OF MORE THAN 3800 CASES AT BGU FRANKFURT , 2004 .

[6]  B. Davies,et al.  Robotic surgery , 1993, IEEE Engineering in Medicine and Biology Magazine.

[7]  Mamoru Mitsuishi,et al.  Continuous path controller of slave manipulator in remote ultrasound diagnostic system , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[8]  Mamoru Mitsuishi,et al.  Remote ultrasound diagnostic system , 2001, Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164).

[9]  Chee-Keong Kwoh,et al.  The safety issues of medical robotics , 2001, Reliab. Eng. Syst. Saf..

[10]  S. J. Harris,et al.  The first clinical application of a "hands-on" robotic knee surgery system. , 2001, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[11]  K. Cleary,et al.  State of the art in surgical robotics: clinical applications and technology challenges. , 2001, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[12]  Clément Gosselin,et al.  Workspace analysis and optimal design of a 3-leg 6-DOF parallel platform mechanism , 2003, IEEE Trans. Robotics Autom..

[13]  Wen-Hong Zhu,et al.  Image-guided control of a robot for medical ultrasound , 2002, IEEE Trans. Robotics Autom..

[14]  Mircea Badescu,et al.  Workspace Optimization of 3-Legged UPU and UPS Parallel Platforms With Joint Constraints , 2004 .