A Time-Frequency Approach for Cerebral Embolic Load Monitoring

Objective: To enable reliable cerebral embolic load monitoring from high-intensity transient signals (HITS) recorded with single-channel transcranial Doppler (TCD) ultrasound. Methods: We propose a HITS detection and characterization method using a weighted-frequency Fourier linear combiner that estimates baseline Doppler signal power. An adaptive threshold is determined by examining the Doppler signal power variance about the baseline estimate, and HITS are extracted if their Doppler power exceeds this threshold. As signatures from multiple emboli may be superimposed, we analyze the detected HITS in the time-frequency (TF) domain to segment the signals into individual emboli. A logistic regression classification approach is employed to classify HITS into emboli or artifacts. Data were collected using a commercial TCD device with emboli-detection capabilities from 12 children undergoing mechanical circulatory support or cardiac catheterization. A subset of 696 HITS were reviewed, annotated, and split into training and testing sets for developing and evaluating the HITS classification algorithm. Results: The classifier yielded 98% and 96% sensitivity for 100% specificity on training and testing data, respectively. The TF approach decomposed 38% of candidate embolic signals into two or more embolic events that ultimately account for 69% of the overall embolic counts. Our processing pipeline resulted in highly accurate emboli identification and produced emboli counts that were lower (by a median of 64%) compared to the commercial ultrasound system's estimates. Significance: Using only single-channel, single-frequency Doppler ultrasound, the proposed method enables sensitive detection and segmentation of embolic signatures. Our approach paves the way toward accurate real-time cerebral emboli monitoring.

[1]  K. Kapur,et al.  Cerebral High‐Intensity Transient Signals during Pediatric Cardiac Catheterization: A Pilot Study Using Transcranial Doppler Ultrasonography , 2017, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[2]  Philippe Delachartre,et al.  Sequential Emboli Detection From Ultrasound Outpatient Data , 2019, IEEE Journal of Biomedical and Health Informatics.

[3]  E. Bosco,et al.  Microembolic signals and strategy to prevent gas embolism during extracorporeal membrane oxygenation , 2010, Journal of cardiothoracic surgery.

[4]  J. Copeland,et al.  Multicenter experience with the thoratec ventricular assist device in children and adolescents. , 2001, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  A. Rabinstein,et al.  Neurologic Complications of Extracorporeal Membrane Oxygenation , 2015, Journal of clinical neurology.

[6]  Ryan P. Barbaro,et al.  Pediatric Extracorporeal Life Support Organization Registry International Report 2016 , 2017, ASAIO journal.

[7]  Denis Kouame,et al.  Synchronous Detection of Emboli by wavelet packet decomposition , 2007, 2007 IEEE International Conference on Acoustics, Speech and Signal Processing - ICASSP '07.

[8]  F. Moll,et al.  Validation of the Automated Electronic Microemboli Detection System in Patients Undergoing Carotid Endarterectomy , 2017, Ultraschall in der Medizin - European Journal of Ultrasound.

[9]  Phongphan Phienphanich,et al.  Automated Cerebral Emboli Detection Using Adaptive Threshold and Adaptive Neuro-Fuzzy Inference System , 2018, IEEE Access.

[10]  R. Brucher,et al.  Online Automatic Discrimination Between Solid and Gaseous Cerebral Microemboli With the First Multifrequency Transcranial Doppler , 2002, Stroke.

[11]  D. Crammond,et al.  Transcranial Doppler Monitoring in Carotid Endarterectomy: A Systematic Review and Meta‐analysis , 2017, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[12]  G. Jarvik,et al.  Increasing duration of deep hypothermic circulatory arrest is associated with an increased incidence of postoperative electroencephalographic seizures. , 2005, The Journal of thoracic and cardiovascular surgery.

[13]  E. Chung,et al.  An In Vitro Comparison of Embolus Differentiation Techniques for Clinically Significant Macroemboli: Dual-Frequency Technique versus Frequency Modulation Method , 2014, Ultrasound in medicine & biology.

[14]  M. McHugh Interrater reliability: the kappa statistic , 2012, Biochemia medica.

[15]  R. Brucher,et al.  Automatic Online Embolus Detection and Artifact Rejection With the First Multifrequency Transcranial Doppler , 2002, Stroke.

[16]  E. Zackai,et al.  The relationship of postoperative electrographic seizures to neurodevelopmental outcome at 1 year of age after neonatal and infant cardiac surgery. , 2006, The Journal of thoracic and cardiovascular surgery.

[17]  M.A. Moehring,et al.  Pulse Doppler ultrasound detection, characterization and size estimation of emboli in flowing blood , 1994, IEEE Transactions on Biomedical Engineering.

[18]  O. Salvetti,et al.  Microembolic signal characterization by transcranial Doppler imaging , 2007, Pattern Recognition and Image Analysis.

[19]  Paul Wintz,et al.  Digital image processing (2nd ed.) , 1987 .

[20]  D H Evans,et al.  Consensus on microembolus detection by TCD. International Consensus Group on Microembolus Detection. , 1998, Stroke.

[21]  Alan V. Oppenheim,et al.  Discrete-time signal processing (2nd ed.) , 1999 .

[22]  P. Despland,et al.  Solid or Gaseous Circulating Brain Emboli: Are They Separable by Transcranial Ultrasound? , 2004, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[23]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[24]  Cameron N. Riviere,et al.  Modeling and canceling tremor in human-machine interfaces , 1996 .

[25]  Nizamettin Aydin,et al.  Analysis of embolic signals with directional dual tree rational dilation wavelet transform , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[26]  M. Moehring,et al.  Power M-mode Doppler (PMD) for observing cerebral blood flow and tracking emboli. , 2002, Ultrasound in medicine & biology.

[27]  J. Lubbers,et al.  An ultrasonic detector for microgasemboli in a bloodflow line. , 1977, Ultrasound in medicine & biology.

[28]  N Aydin,et al.  The use of the wavelet transform to describe embolic signals. , 1999, Ultrasound in medicine & biology.

[29]  Jacob Cohen A Coefficient of Agreement for Nominal Scales , 1960 .

[30]  D. Evans,et al.  A comparison of four methods for distinguishing Doppler signals from gaseous and particulate emboli. , 1998, Stroke.

[31]  Manfred Kaps,et al.  Consensus on Microembolus Detection by TCD , 1998 .

[32]  K. Kapur,et al.  Patterns of Head Computed Tomography Abnormalities During Pediatric Extracorporeal Membrane Oxygenation and Association With Outcomes. , 2017, Pediatric neurology.

[33]  T. Treasure,et al.  The Impact of Microemboli During Cardiopulmonary Bypass on Neuropsychological Functioning , 1994, Stroke.

[34]  Takamasa Sato,et al.  Evaluation of micro-emboli in a patient with ventricular assist device support with hemolysis , 2015, Journal of Artificial Organs.

[35]  J. Jensen Estimation of Blood Velocities Using Ultrasound: A Signal Processing Approach , 1996 .

[36]  A. Hoeks,et al.  Quantification of embolic showers using radio-frequency based TCD analysis. , 2009, Ultrasound in medicine & biology.

[37]  M. Bonizzoli,et al.  Cerebral microemboli detected by transcranial doppler in patients treated with extracorporeal membrane oxygenation , 2016, Acta anaesthesiologica Scandinavica.

[38]  Jean-Marc Girault,et al.  A new energy detector of micro-emboli using a time-varying threshold , 2015, 2015 International Conference on Advances in Biomedical Engineering (ICABME).

[39]  Adem Karahoca,et al.  A polynomial based algorithm for detection of embolism , 2015, Soft Comput..

[40]  F. Rubens,et al.  Sources of Variability in the Detection of Cerebral Emboli with Transcranial Doppler During Cardiac Surgery , 2006, Journal of neuroimaging : official journal of the American Society of Neuroimaging.