Comparison of 3T and 7T ASL techniques for concurrent functional perfusion and BOLD studies

&NA; Arterial spin labeling (ASL) is the primary non‐invasive MRI approach to measure baseline cerebral blood flow (CBF) in healthy subjects and patients. ASL also allows concurrent functional BOLD signal and CBF measurements, but the latter typically suffer from low contrast‐to‐noise (CNR) ratio. Ultra‐high‐field imaging significantly boosts BOLD signal CNR. However, it is contested whether also CBF CNR benefits from increasing magnetic field strength, especially given that technical challenges related to field inhomogeneities and power deposition constraints exist. Recently, we presented an optimized PASL technique that utilizes tr‐FOCI inversion pulses and dielectric pads to overcome the temporal resolution limitations of previous 7 T ASL implementations (Ivanov et al., in press; 2017). The primary goal of this study was to compare its performance to that of 3 T ASL approaches – both pulsed ASL (PASL) and pseudo‐continuous (pCASL) – concerning functional studies using simultaneous CBF and BOLD signal acquisition. To this aim, we investigated a wide range of parameters that can influence CBF and BOLD signal sensitivities: spatial resolution, labeling scheme, parallel imaging and echo time. We found that 7 T ASL is superior in terms of CBF and BOLD temporal signal‐to‐noise ratio (SNR) and activation volume compared to all 3 T ASL variants, in particular at high spatial resolution. Our results show that the advantages of 7 T for ASL stem from increased image SNR, especially when parallel imaging is used. The gray matter baseline CBF was in good agreement for all 3 T ASL variants, but a significantly lower value was obtained at 7 T. The labeling scheme utilized was also found to significantly influence the measured perfusion territories CBF. In conclusion, a single‐echo accelerated 7 T PASL is recommended for high spatial and temporal resolution CBF and BOLD imaging, while a 3 T dual‐echo pCASL approach without parallel imaging may be preferred for low (i.e., 3 mm isotropic and lower) resolution functional perfusion and BOLD applications. Highlights7 T PASL was compared to PASL and pCASL techniques at 3 T.7 T ASL outperforms 3T ASL at high spatial resolutions & when parallel imaging is used.7 T PASL allows high spatial and temporal resolution CBF measurements.3 T dual‐echo pCASL is adequate for low resolution functional CBF and BOLD imaging.

[1]  P. E. Morris,et al.  Water proton T1 measurements in brain tissue at 7, 3, and 1.5T using IR-EPI, IR-TSE, and MPRAGE: results and optimization , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[2]  Thomas E. Nichols,et al.  Estimation efficiency and statistical power in arterial spin labeling fMRI , 2006, NeuroImage.

[3]  P. Bandettini,et al.  QUIPSS II with thin‐slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling , 1999, Magnetic resonance in medicine.

[4]  Anders M. Dale,et al.  An automated labeling system for subdividing the human cerebral cortex on MRI scans into gyral based regions of interest , 2006, NeuroImage.

[5]  Yves Rosseel,et al.  On the Definition of Signal-To-Noise Ratio and Contrast-To-Noise Ratio for fMRI Data , 2013, PloS one.

[6]  Kamil Ugurbil,et al.  An integrative model for neuronal activity-induced signal changes for gradient and spin echo functional imaging , 2009, NeuroImage.

[7]  D. Alsop,et al.  Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields , 2008, Magnetic resonance in medicine.

[8]  J. Pfeuffer,et al.  Pulsed arterial spin labelling at ultra-high field with a B1+-optimised adiabatic labelling pulse , 2016, Magnetic Resonance Materials in Physics, Biology and Medicine.

[9]  X. Zhang,et al.  In vivo blood T1 measurements at 1.5 T, 3 T, and 7 T , 2013, Magnetic resonance in medicine.

[10]  Anders M. Dale,et al.  Automatic parcellation of human cortical gyri and sulci using standard anatomical nomenclature , 2010, NeuroImage.

[11]  Xavier Golay,et al.  Accelerated parallel imaging for functional imaging of the human brain , 2006, NMR in biomedicine.

[12]  Chen Lin,et al.  Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T , 2011, NeuroImage.

[13]  Laurentius Huber,et al.  Techniques for blood volume fMRI with VASO: From low-resolution mapping towards sub-millimeter layer-dependent applications , 2018, NeuroImage.

[14]  R. Buxton,et al.  Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II) , 1998 .

[15]  Stefan Skare,et al.  How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging , 2003, NeuroImage.

[16]  J Wang,et al.  Effects of the apparent transverse relaxation time on cerebral blood flow measurements obtained by arterial spin labeling , 2005, Magnetic resonance in medicine.

[17]  Xavier Golay,et al.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla , 2004, Magnetic resonance in medicine.

[18]  Andrew G. Webb,et al.  Feasibility of pseudocontinuous arterial spin labeling at 7 T with whole-brain coverage , 2011, Magnetic Resonance Materials in Physics, Biology and Medicine.

[19]  G. Zaharchuk,et al.  Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. , 2015, Magnetic resonance in medicine.

[20]  Dae-Shik Kim,et al.  Localized cerebral blood flow response at submillimeter columnar resolution , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[21]  R. Buxton,et al.  Variability of the coupling of blood flow and oxygen metabolism responses in the brain: a problem for interpreting BOLD studies but potentially a new window on the underlying neural activity , 2014, Front. Neurosci..

[22]  A. Shmuel,et al.  Perfusion‐based high‐resolution functional imaging in the human brain at 7 Tesla , 2002, Magnetic resonance in medicine.

[23]  Andrew G. Webb,et al.  Arterial spin labeling at ultra-high field: All that glitters is not gold , 2010 .

[24]  Felix W. Wehrli,et al.  Calibrated bold fMRI with an optimized ASL-BOLD dual-acquisition sequence , 2016, NeuroImage.

[25]  Donald S. Williams,et al.  Perfusion imaging , 1992, Magnetic resonance in medicine.

[26]  S. Francis,et al.  Implementation of quantitative perfusion imaging using pulsed arterial spin labeling at ultra‐high field , 2009, Magnetic resonance in medicine.

[27]  K. Uğurbil,et al.  Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths. , 2007, Magnetic resonance imaging.

[28]  Josef Pfeuffer,et al.  Optimization of simultaneous multislice EPI for concurrent functional perfusion and BOLD signal measurements at 7T , 2016, Magnetic resonance in medicine.

[29]  Klaus Scheffler,et al.  Signal‐to‐noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arrays , 2016, Magnetic resonance in medicine.

[30]  D. Weinberger,et al.  Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST) , 2000, Magnetic resonance in medicine.

[31]  J. Desmond,et al.  Three‐dimensional whole‐brain perfusion quantification using pseudo‐continuous arterial spin labeling MRI at multiple post‐labeling delays: accounting for both arterial transit time and impulse response function , 2014, NMR in biomedicine.

[32]  Wedge‐shaped slice‐selective adiabatic inversion pulse for controlling temporal width of bolus in pulsed arterial spin labeling , 2016, Magnetic resonance in medicine.

[33]  Hesamoddin Jahanian,et al.  Quantitative analysis of arterial spin labeling FMRI data using a general linear model. , 2010, Magnetic resonance imaging.

[34]  Peter G. Morris,et al.  fMRI at 1.5, 3 and 7 T: Characterising BOLD signal changes , 2009, NeuroImage.

[35]  Andreas Bartels,et al.  Retinotopic maps and hemodynamic delays in the human visual cortex measured using arterial spin labeling , 2012, NeuroImage.

[36]  Irene Tracey,et al.  Quantitative assessment of the reproducibility of functional activation measured with BOLD and MR perfusion imaging: Implications for clinical trial design , 2005, NeuroImage.

[37]  David G Norris,et al.  High field human imaging , 2003, Journal of magnetic resonance imaging : JMRI.

[38]  Lawrence L Wald,et al.  Massively parallel MRI detector arrays. , 2013, Journal of magnetic resonance.

[39]  Peter Jezzard,et al.  Investigating white matter perfusion using optimal sampling strategy arterial spin labeling at 7 Tesla , 2014, Magnetic resonance in medicine.

[40]  J. Butman,et al.  Whole‐brain cerebral blood flow mapping using 3D echo planar imaging and pulsed arterial tagging , 2011, Journal of magnetic resonance imaging : JMRI.

[41]  D. S. Williams,et al.  Magnetic resonance imaging of perfusion using spin inversion of arterial water. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[42]  Uwe Aickelin,et al.  Tailored RF pulse for magnetization inversion at ultrahigh field , 2010, Magnetic resonance in medicine.

[43]  Wen-Ming Luh,et al.  Pseudo‐continuous arterial spin labeling at 7 T for human brain: Estimation and correction for off‐resonance effects using a Prescan , 2013, Magnetic resonance in medicine.

[44]  P. Jezzard,et al.  Quantitative measurement of cerebral physiology using respiratory-calibrated MRI , 2012, NeuroImage.

[45]  J. Detre,et al.  Technical aspects and utility of fMRI using BOLD and ASL , 2002, Clinical Neurophysiology.

[46]  Andrew G Webb,et al.  Quantitative assessment of the effects of high‐permittivity pads in 7 Tesla MRI of the brain , 2012, Magnetic resonance in medicine.

[47]  B. Erdoğmuş,et al.  Cerebral blood flow measurements of the extracranial carotid and vertebral arteries with Doppler ultrasonography in healthy adults. , 2005, Diagnostic and interventional radiology.

[48]  Lawrence L. Wald,et al.  The future of acquisition speed, coverage, sensitivity, and resolution , 2012, NeuroImage.

[49]  J. Bogousslavsky,et al.  Arterial territories of the human brain , 1998, Neurology.

[50]  Peter R Luijten,et al.  Blood oxygenation level‐dependent (BOLD) total and extravascular signal changes and ΔR2* in human visual cortex at 1.5, 3.0 and 7.0 T , 2011, NMR in biomedicine.

[51]  Lawrence L. Wald,et al.  Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils , 2011, NeuroImage.

[52]  Yufen Chen,et al.  Test–retest reliability of arterial spin labeling with common labeling strategies , 2011, Journal of magnetic resonance imaging : JMRI.

[53]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[54]  Mark W. Woolrich,et al.  Advances in functional and structural MR image analysis and implementation as FSL , 2004, NeuroImage.

[55]  Peter C M van Zijl,et al.  An account of the discrepancy between MRI and PET cerebral blood flow measures. A high‐field MRI investigation , 2006, NMR in biomedicine.

[56]  K. Uğurbil,et al.  Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scaling , 2004, Magnetic resonance in medicine.

[57]  J. Detre,et al.  Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease , 1998, Neurology.

[58]  Yi Wang,et al.  Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7T , 2015, NeuroImage.

[59]  K. Uğurbil,et al.  High‐resolution, spin‐echo BOLD, and CBF fMRI at 4 and 7 T , 2002, Magnetic resonance in medicine.

[60]  P. A. Gowland,et al.  Double Acquisition Background Suppressed ( DABS ) FAIR at 3 T and 7 T : advantages for simultaneous BOLD and CBF acquisition , 2008 .

[61]  John A. Detre,et al.  Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences , 2013, NeuroImage.

[62]  J. Detre,et al.  A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling , 2007, Magnetic resonance in medicine.

[63]  Steen Moeller,et al.  T 1 weighted brain images at 7 Tesla unbiased for Proton Density, T 2 ⁎ contrast and RF coil receive B 1 sensitivity with simultaneous vessel visualization , 2009, NeuroImage.

[64]  Karl J. Friston,et al.  Physiologically informed dynamic causal modeling of fMRI data , 2015, NeuroImage.

[65]  Michael A. Chappell,et al.  Effects of background suppression on the sensitivity of dual-echo arterial spin labeling MRI for BOLD and CBF signal changes , 2014, NeuroImage.

[66]  Lawrence L. Wald,et al.  Three dimensional echo-planar imaging at 7 Tesla , 2010, NeuroImage.

[67]  Thorsten Feiweier,et al.  Reducing sensitivity losses due to respiration and motion in accelerated echo planar imaging by reordering the autocalibration data acquisition , 2016, Magnetic resonance in medicine.

[68]  E C Wong,et al.  Comparison of simultaneously measured perfusion and BOLD signal increases during brain activation with T1‐based tissue identification , 2000, Magnetic resonance in medicine.

[69]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[70]  Klaus Scheffler,et al.  Quantitative and functional pulsed arterial spin labeling in the human brain at 9.4 t , 2016, Magnetic resonance in medicine.

[71]  Stephen M. Smith,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[72]  Danny J. J. Wang,et al.  Turbo-FLASH Based Arterial Spin Labeled Perfusion MRI at 7 T , 2013, PloS one.

[73]  K. Uğurbil,et al.  Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo , 2007, Magnetic resonance in medicine.

[74]  John A. Detre,et al.  Comparison of arterial transit times estimated using arterial spin labeling , 2012, Magnetic Resonance Materials in Physics, Biology and Medicine.

[75]  R. Buxton,et al.  Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling , 1997, NMR in biomedicine.

[76]  Josef Pfeuffer,et al.  Comparison of pulsed arterial spin labeling encoding schemes and absolute perfusion quantification. , 2009, Magnetic resonance imaging.

[77]  Bruce Fischl,et al.  Highly accurate inverse consistent registration: A robust approach , 2010, NeuroImage.

[78]  S. Riederer,et al.  Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imaging , 1990, Magnetic resonance in medicine.

[79]  Gary F. Egan,et al.  Regional reproducibility of calibrated BOLD functional MRI: Implications for the study of cognition and plasticity , 2014, NeuroImage.