Reproducibility of kinematic motion coupling parameters during manual upper cervical axial rotation mobilization: a 3-dimensional in vitro study of the atlanto-axial joint.

INTRODUCTION The reproducibility of the 3-dimensional (3D) kinematic aspects of motion coupling patterns of segmental manual mobilizing techniques is not yet known. This study analyzes the segmental 3D aspects of manual mobilization of the atlanto-axial joint in vitro. METHODS AND MATERIALS Twenty fresh human cervical specimens were studied in a test-retest situation with two examiners. The specimens were manually mobilized using three different techniques: a regional mobilization technique, a segmental mobilization technique on the atlas with manual fixation of the axis and a segmental mobilization applying a locking technique. Segmental kinematics were registered with a Zebris CMS20 ultrasound-based tracking system. The 3D aspects of motion coupling between main axial rotation and coupled lateral bending were analyzed by six parameters: the range of motion the three motion components, the cross-correlation, the ratio and the shift. RESULTS The results indicate stronger intra- than inter-examiner reproducibility. The range of motion of the axial rotation component shows a substantial level of intra- and inter-examiner reproducibility (ICC's 0.67-0.76). The parameters describing the coupling patterns show only moderate to substantial intra-examiner reproducibility for the more experienced of the two examiners (ICC's 0.55-0.68). All other correlations were not significant and no differences could be observed between regional versus segmental techniques. CONCLUSION Reproducibility of segmental 3D-aspects of manual mobilization of the atlanto-axial joint in an in vitro situation can differ between examiners. The results of the present study may indicate a possible tendency to higher reproducibility if mobilizations are performed by an examiner with high expertise and experience in applying the specific techniques. Continued investigation including more examiners with different levels of experience and different techniques is necessary to confirm these observations.

[1]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[2]  A. Garratt,et al.  Assessment of the 3-dimensional Fastrak measurement system in measuring range of motion in ankylosing spondylitis. , 2004, The Journal of rheumatology.

[3]  J. Clarys,et al.  Does manual mobilization influence motion coupling patterns in the atlanto-axial joint? , 2008, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[4]  S. Edmondston,et al.  Influence of cranio-cervical posture on three-dimensional motion of the cervical spine. , 2005, Manual therapy.

[5]  Fredrik Johansson Interexaminer reliability of lumbar segmental mobility tests. , 2006, Manual therapy.

[6]  M. Bulgheroni,et al.  3D Kinematic Analysis and Clinical Evaluation of Neck Movements in Patients with Whiplash Injury , 2002, Cephalalgia : an international journal of headache.

[7]  N. Milne,et al.  Composite motion in cervical disc segments. , 1993, Clinical biomechanics.

[8]  P. Gibbons,et al.  Inter-examiner and intra-examiner reliability of the standing flexion test. , 1999, Manual therapy.

[9]  M. Bracke,et al.  Intratester and intertester reliability of the cervical range of motion device. , 1991, Archives of physical medicine and rehabilitation.

[10]  S Siegler,et al.  Three‐Dimensional Flexibility Characteristics of the Human Cervical Spine In Vivo , 1998, Spine.

[11]  M. Rondeau,et al.  Reliability of the Cervical Range of Motion (CROM) Device and Plumb-Line Techniques in Measuring Resting Head Posture (RHP) , 2000 .

[12]  L E Claes,et al.  Formalin fixation strongly influences biomechanical properties of the spine. , 1996, Journal of biomechanics.

[13]  Herman J. Woltring,et al.  Representation and calculation of 3-D joint movement , 1991 .

[14]  Kwan-Hwa Lin,et al.  Measurement of cervical range of motion pattern during cyclic neck movement by an ultrasound-based motion system. , 2005, Manual therapy.

[15]  A. Mannion,et al.  A new skin-surface device for measuring the curvature and global and segmental ranges of motion of the spine: reliability of measurements and comparison with data reviewed from the literature , 2004, European Spine Journal.

[16]  L. Brosseau,et al.  Intratester and intertester reliability of the Cybex electronic digital inclinometer (EDI-320) for measurement of active neck flexion and extension in healthy subjects. , 2001, Manual therapy.

[17]  L. Vogt,et al.  Reproduzierbarkeit thorakaler und lumbaler Wirbelsäulenbewegungen mit der 3D-Ultraschalltopometrie , 1997 .

[18]  C C Wright,et al.  Reproducibility and repeatability: errors of three groups of physiotherapists in locating spinal levels by palpation. , 2003, Manual therapy.

[19]  Alan C Bovik,et al.  A New Technique for Digital Fluoroscopic Video Assessment of Sagittal Plane Lumbar Spine Motion , 2005, Spine.

[20]  M. Normand,et al.  Measurement of the pressure applied during motion palpation and reliability for cervical spine rotation. , 2005, Journal of manipulative and physiological therapeutics.

[21]  Jennifer M Muggleton,et al.  An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data , 2006, BMC musculoskeletal disorders.

[22]  M M Panjabi,et al.  Three‐dimensional load‐displacement curves due to froces on the cervical spine , 1986, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  G. Jull,et al.  Measuring range of active cervical rotation in a position of full head flexion using the 3D Fastrak measurement system: an intra-tester reliability study. , 2003, Manual therapy.

[24]  M. Pearcy,et al.  Three-dimensional analysis of active cervical motion: the effect of age and gender. , 1996, Clinical biomechanics.

[25]  T. R. Garrett,et al.  Normal range of motion of the cervical spine: an initial goniometric study. , 1992, Physical therapy.

[26]  A. Mannion,et al.  Range of global motion of the cervical spine: intraindividual reliability and the influence of measurement device , 2000, European Spine Journal.

[27]  Manual forces applied during cervical mobilization. , 2007, Journal of manipulative and physiological therapeutics.

[28]  P D O'Connor,et al.  Intrasubject reliability of spinal range of motion and velocity determined by video motion analysis. , 1993, Physical therapy.

[29]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[30]  Michael John Haynes,et al.  Accuracy and reliability of a new, protractor-based neck goniometer. , 2002, Journal of manipulative and physiological therapeutics.

[31]  C. Seymour,et al.  Reliability of the Cervical Range of Motion Device in Measuring Upper Cervical Motion , 1998 .

[32]  A. Schultz,et al.  Loads Transmitted During Lumbosacral Spinal Manipulative Therapy , 1997, Spine.

[33]  A. König,et al.  Nichtinvasive, akkurate und reliable Messung der Halswirbelsäulenbeweglichkeit mittels ultraschallgestützter 3D-Echtzeit-Bewegungsanalyse , 1999 .

[34]  S. Kumar,et al.  Posteroanterior motion test of a lumbar vertebra: accuracy of perception , 2003, Disability and rehabilitation.

[35]  W. Vach,et al.  Palpation of the upper thoracic spine: an observer reliability study. , 2002, Journal of manipulative and physiological therapeutics.

[36]  R. Swinkels,et al.  Upper cervical instability: are clinical tests reliable? , 1997, Manual therapy.

[37]  P. Jones,et al.  The reliability of the three-dimensional FASTRAK measurement system in measuring cervical spine and shoulder range of motion in healthy subjects. , 2000, Rheumatology.

[38]  Triano Jj,et al.  Motions of the head and thorax during neck manipulations. , 1994 .

[39]  L. Bouter,et al.  The interexaminer reproducibility of physical examination of the cervical spine. , 2004, Journal of manipulative and physiological therapeutics.

[40]  G Ferrigno,et al.  Non-invasive approach towards the in vivo estimation of 3D inter-vertebral movements: methods and preliminary results. , 2004, Medical engineering & physics.

[41]  M. Panjabi,et al.  Posture affects motion coupling patterns of the upper cervical spine , 1993, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[42]  V. Feipel,et al.  The use of 3d electrogoniometry to assess kinematics and functional outcome of various cervical spine manual techniques , 2000 .

[43]  C. Hawk,et al.  Preliminary study of the reliability of assessment procedures for indications for chiropractic adjustments of the lumbar spine. , 1999, Journal of manipulative and physiological therapeutics.

[44]  William Duquet,et al.  The clinical examination of neck pain patients: the validity of a group of tests. , 2007, Manual therapy.

[45]  J. Clarys,et al.  Measurement of three-dimensional intra-articular kinematics: methodological and interpretation problems , 2005, Ergonomics.

[46]  A. Kachingwe,et al.  Inter- and intrarater reliability of a back range of motion instrument. , 2005, Archives of physical medicine and rehabilitation.

[47]  G. Jull,et al.  Measurement of Upper Cervical Flexion and Extension with the 3-Space Fastrak Measurement System: A Repeatability Study , 2003 .

[48]  P. Khalsa,et al.  High loading rate during spinal manipulation produces unique facet joint capsule strain patterns compared with axial rotations. , 2005, Journal of manipulative and physiological therapeutics.

[49]  M. Panjabi,et al.  Biomechanical time‐tolerance of fresh cadaveric human spine specimens , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[50]  L. Murphy,et al.  Reliability of Spinal Palpation for Diagnosis of Back and Neck Pain: A Systematic Review of the Literature , 2004, Spine.

[51]  Panzer Dm The reliability of lumbar motion palpation. , 1992 .

[52]  V. Feipel,et al.  Global 3D head-trunk kinematics during cervical spine manipulation at different levels. , 2003, Clinical biomechanics.

[53]  D. Harrison,et al.  Three-dimensional spinal coupling mechanics: Part II. Implications for chiropractic theories and practice. , 1998, Journal of manipulative and physiological therapeutics.

[54]  H. Woltring 3-D attitude representation of human joints: a standardization proposal. , 1994, Journal of biomechanics.

[55]  S Micera,et al.  A protocol for the assessment of 3D movements of the head in persons with cervical dystonia. , 2004, Clinical biomechanics.

[56]  M. Piché,et al.  Development of a computerized intervertebral motion analysis of the cervical spine for clinical application. , 2007, Journal of manipulative and physiological therapeutics.