Using photoplethysmography in heart rate monitoring of patients with epilepsy

Heart rate is a useful neurophysiological sign when monitoring seizures in patients with epilepsy. In an ambulatory setting, heart rate is measured with ECG involving electrodes on the skin. This method is uncomfortable which is burdensome for patients and is sensitive to motion artifacts, which decrease the usability of measurements. In this study, green light photoplethysmography, an optical technique arising from the fitness industry, was evaluated for usefulness in a medical setting. Simultaneous overnight measurements of HR with a commercially available optical heart rate (OHR) sensor and with ECG (HRECG) were performed in 7 patients with epilepsy. Overall, there was no significant difference between OHR and HRECG in random 10-minute periods during wakefulness (p=0.69) and sleep (p=1.00). The Bland-Altman analysis showed negligible mean differences. Limits of agreement were higher during wakefulness and during the occurrence of two seizures possibly because of less reliable HRECG measurements due to motion artifacts. Optical heart rate seems less sensitive to these motion artifacts, and measurements are more user-friendly. The optical heart rate sensor may fill the gap of systems for ambulatory heart rate monitoring and can be especially useful in the context of seizure detection in patients with epilepsy.

[1]  Shinobu Tanaka,et al.  Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[2]  M. Ezekowitz,et al.  2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the Heart Rhythm Society. , 2014, Circulation.

[3]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[4]  W.J. Tompkins,et al.  ECG beat detection using filter banks , 1999, IEEE Transactions on Biomedical Engineering.

[5]  Toshiyo Tamura,et al.  The Advantages of Wearable Green Reflected Photoplethysmography , 2011, Journal of Medical Systems.

[6]  Josemir W Sander,et al.  Sudden unexpected death in epilepsy: People with nocturnal seizures may be at highest risk , 2012, Epilepsia.

[7]  J. Gotman,et al.  Heart Rate Changes and ECG Abnormalities During Epileptic Seizures: Prevalence and Definition of an Objective Clinical Sign , 2002, Epilepsia.

[8]  M. Ezekowitz,et al.  2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the Heart Rhythm Society. , 2014, Circulation.

[9]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .

[10]  Tamara M.E. Nijsen,et al.  A model of heart rate changes to detect seizures in severe epilepsy , 2006, Seizure.