High-Strength Concrete Columns under Eccentric Load

The behavior of high strength concrete tied columns was investigated. A total of 11 columns were tested under monotonic loading having two different eccentricities. The main variables investigated were: (1) the mechanical ratio, (2) the spacing, and (3) the configuration of transverse reinforcement. Test results indicate that, under monotonically increasing axial load, the cross ties with a 135° hook at one end and 90° bent at the other end provide ductility comparable to ties supporting the intermediate longitudinal bars. Also the use of four different equivalent rectangular stress blocks (ERSBs) in predicting the ultimate strength of members made of high strength concrete was evaluated. It is concluded that calculations made using the ACI 318-02 stress block always gives an upper bound, whereas a lower bound is obtained by the CSA A23.3-94 approach. Capacities calculated using the ERSB proposed by Bae and Bayrak, and Ozbakkaloglu and Saatcioglu also agree quite well with the test results.

[1]  Togay Ozbakkaloglu,et al.  Rectangular Stress Block for High-Strength Concrete , 2004 .

[2]  Murat Saatcioglu,et al.  Strength and Deformability of Confined High-Strength Concrete Columns , 1994 .

[3]  R. Park,et al.  Flexural Members with Confined Concrete , 1971 .

[4]  Murat Saatcioglu,et al.  High-Strength Concrete Columns with Square Sections under Concentric Compression , 1998 .

[5]  James L Noland,et al.  Computer-Aided Structural Engineering (CASE) Project: Decision Logic Table Formulation of ACI (American Concrete Institute) 318-77 Building Code Requirements for Reinforced Concrete for Automated Constraint Processing. Volume 1. , 1986 .

[6]  Yan Xiao,et al.  SEISMIC PERFORMANCE OF HIGH-STRENGTH CONCRETE COLUMNS , 1998 .

[7]  Y.-K. Yong,et al.  Behavior of Laterally Confined High‐Strength Concrete under Axial Loads , 1988 .

[8]  Patrick Paultre,et al.  High‐Strength Concrete Columns Confined by Rectangular Ties , 1994 .

[9]  E. Bentz Sectional analysis of reinforced concrete members , 2000 .

[10]  A. Mattock,et al.  Rectangular Concrete Stress Distribution in Ultimate Strength Design , 1961 .

[11]  Murat Saatcioglu,et al.  Circular High-Strength Concrete Columns under Simulated Seismic Loading , 1999 .

[12]  T. Nagashima,et al.  Experimental Studies on Seismic Behavior of Reinforced Concrete Members of High-Strength Concrete , 1990, SP-121: High-Strength Concrete: Second International Symposium.

[13]  Shamim A. Sheikh,et al.  Analytical Model for Concrete Confinement in Tied Columns , 1982 .

[14]  James G. MacGregor,et al.  Tests of Eccentrically Loaded High-StrengthConcrete Columns , 1996 .

[15]  Murat Saatcioglu,et al.  Strength and Ductility of Confined Concrete , 1992 .

[16]  A. Azizinamini,et al.  Seismic behavior of square high-strength concrete columns , 1994 .

[17]  M. Saatcioglu,et al.  Confinement Model for High-Strength Concrete , 1999 .

[18]  Oguzhan Bayrak,et al.  STRESS BLOCK PARAMETERS FOR HIGH-STRENGTH CONCRETE MEMBERS , 2003 .

[19]  Charles S. Whitney,et al.  Design of Reinforced Concrete Members Under Flexure or Combined Flexure and Direct Compression , 1937 .

[20]  Stephen J. Foster,et al.  Cover Spalling in HSC Columns Loaded in Concentric Compression , 1998 .