Contrast-enhanced MR imaging of coronary arteries: comparison of intra- and extravascular contrast agents in swine.

PURPOSE To compare the efficacy of an intravascular contrast agent, gadomer-17, in improving magnetic resonance (MR) imaging of coronary arteries with that of an extravascular agent, gadopentetate dimeglumine, in pigs. MATERIALS AND METHODS Eight pigs underwent imaging after three injections: 0.20 mmol of gadopentetate dimeglumine per kilogram of body weight and 0.05 and 0.10 mmol/kg gadomer-17. Coronary images were acquired repeatedly after each injection by using an inversion-recovery-prepared segmented three-dimensional sequence with either breath holding (n = 4) or respiratory gating (n = 4). Coronary artery-to-myocardium contrast-to-noise ratios (CNRs) were compared between injections. RESULTS At breath-hold imaging, substantial CNR improvement over precontrast images was observed in images acquired during the first pass of gadopentetate dimeglumine in coronary arteries and up to 6 and 10 minutes after 0.05 and 0.10 mmol/kg of gadomer-17 injections, respectively. The CNR with 0.10 mmol/kg of gadomer-17 was 20% (P <.05) higher than that with gadopentetate dimeglumine at first-pass imaging. At respiratory-gated imaging, significant CNR improvement (P <.05) over precontrast images was observed in images acquired up to 10, 30, and 50 minutes after gadopentetate dimeglumine and both gadomer-17 injections, respectively. The CNR on the first images obtained after 0.10 mmol/kg gadomer-17 injection was 168% (P <.05) higher than that on the images obtained after gadopentetate dimeglumine injection. CONCLUSION Gadomer-17 provided greater and more persistent CNR improvements than did gadopentetate dimeglumine; further evaluation of its utility for coronary imaging in humans is warranted.

[1]  C. Lorenz,et al.  Benefit of T1 reduction for magnetic resonance coronary angiography: A numerical simulation and phantom study , 1999, Journal of magnetic resonance imaging : JMRI.

[2]  C. Lorenz,et al.  High-resolution magnetic resonance coronary angiography of the entire heart using a new blood-pool agent, NC100150 injection: comparison with invasive x-ray angiography in pigs. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[3]  E. Haacke,et al.  Efficacy of slow infusion of gadolinium contrast agent in three‐dimensional MR coronary artery imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[4]  O Henriksen,et al.  In vivo quantification of the unidirectional influx constant for Gd‐DTPA diffusion across the myocardial capillaries with MR imaging , 1994, Journal of magnetic resonance imaging : JMRI.

[5]  Emmanuelle Canet,et al.  Contrast‐enhanced 3D‐TOF MRA of peripheral vessels: Intravascular versus extracellular MR contrast media , 1998, Journal of magnetic resonance imaging : JMRI.

[6]  S. Riederer,et al.  Three‐dimensional magnetization‐prepared time‐of‐flight MR angiography of the carotid and vertebral arteries , 1997, Magnetic resonance in medicine.

[7]  J Keegan,et al.  Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography , 1999, Journal of magnetic resonance imaging : JMRI.

[8]  R. Dolan,et al.  Three‐dimensional MRI of coronary arteries using an intravascular contrast agent , 1998, Magnetic resonance in medicine.

[9]  E M Haacke,et al.  Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast. , 1993, Radiology.

[10]  René M. Botnar,et al.  Contrast agent‐enhanced, free‐breathing, three‐dimensional coronary magnetic resonance angiography , 1999, Journal of magnetic resonance imaging : JMRI.

[11]  R. Dolan,et al.  MS-325: albumin-targeted contrast agent for MR angiography. , 1998, Radiology.

[12]  C H Lorenz,et al.  Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre‐pulse , 1999, Magnetic resonance in medicine.

[13]  Y Wang,et al.  3D MR angiography of pulmonary arteries using realtime navigator gating and magnetization preparation , 1996, Magnetic resonance in medicine.

[14]  P. Carson,et al.  The American Institute of Ultrasound in Medicine and the Society of Radiologists in Ultrasound--future directions in diagnostic US. , 1998, Radiology.

[15]  D C Peters,et al.  Steady-state and dynamic MR angiography with MS-325: initial experience in humans. , 1998, Radiology.

[16]  A E Stillman,et al.  Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: studies in human patients. , 1996, Journal of computer assisted tomography.

[17]  P J de Feyter,et al.  Breath-hold coronary MR angiography with volume-targeted imaging. , 1998, Radiology.

[18]  S. Achenbach,et al.  Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging--initial experience. , 1999, Radiology.

[19]  S Berr,et al.  Three‐dimensional time‐of‐flight MR angiography using selective inversion recovery RAGE with fat saturation and ECG‐triggering: Application to renal arteries , 1994, Magnetic resonance in medicine.

[20]  René M. Botnar,et al.  Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. , 1999, Circulation.

[21]  E M Haacke,et al.  Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: initial experience. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[22]  E. Haacke,et al.  Accuracy of T1 measurements at high temporal resolution: Feasibility of dynamic measurement of blood T1 after contrast administration , 1999, Journal of magnetic resonance imaging : JMRI.

[23]  René M. Botnar,et al.  Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. , 1999, Journal of the American College of Cardiology.

[24]  R R Edelman,et al.  Coronary arteries: breath-hold, gadolinium-enhanced, three-dimensional MR angiography. , 1998, Radiology.

[25]  Albert Macovski,et al.  Coronary Angiography with Magnetization‐Prepared T2 Contrast , 1995, Magnetic resonance in medicine.

[26]  R. Henkelman Measurement of signal intensities in the presence of noise in MR images. , 1985, Medical physics.

[27]  F R Gutierrez,et al.  Coronary arteries: three-dimensional MR imaging with retrospective respiratory gating. , 1996, Radiology.