Skin photoplethysmography--a review.

The photoplethysmograph has been used for over 50 years but there are still misconceptions in how and what is the information obtained. A photoplethysmograph signal from any site on the skin can be separated into an oscillating (a.c.) and a steady-state (d.c.) component, their amplitudes dependent upon the structure and flow in the vascular bed. Many simple applications are available: pulse counters, using the a.c. component, skin colour and haemoglobin saturation meters, using the d.c. component. The d.c. component of the photoplethysmograph signal is a function of the blood flux beneath the device. A good emitter for use in a photoplethysmograph of skin blood flow is one in the frequency range 600-700 nm and the best signal for a.c. analysis is obtained from the finger pulp. The frequency range of the electronic circuitry should be from 0.01 to 15 Hz, then all the information in the signal can be extracted about the autonomic nervous system control of the cardiovascular system, particularly between 0.01 and 2 Hz. Comparative studies may be drawn between similar skin sites on a subject or between subjects if the afferent inputs to the brain stem are controlled or driven at a known frequency. These afferents, inputs, will modulate the efferents, outputs, which generate variations in the a.c. component of the detected photoplethysmograph signal.

[1]  K. Hagbarth,et al.  Thermoregulatory and rhythm‐generating mechanisms governing the sudomotor and vasoconstrictor outflow in human cutaneous nerves. , 1980, The Journal of physiology.

[2]  V. C. Roberts,et al.  Photoplethysmography- fundamental aspects of the optical properties of blood in motion , 1982 .

[3]  A. B. Hertzman Photoelectric Plethysmography of the Fingers and Toes in Man , 1937 .

[4]  C. Ramsay VASCULAR CHANGES ACCOMPAXVIXG WHITE DERMOGRAPHISM AND DELAYED BLANCH IN ATOPIC DERMATITIS , 1969, The British journal of dermatology.

[5]  A. B. Hertzman THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH , 1938 .

[6]  A. Selman,et al.  The interaction between heart rate and respiration : Part 1 - Experimental studies in man , 1982 .

[7]  Michael Kniazuk,et al.  A NEW BLOODLESS METHOD FOR CONTINUOUS RECORDING OF PERIPHERAL CIRCULATORY CHANGES , 1936 .

[8]  E. Cummings Temperature and concentration effects on penetration of N-octylamine through human skin in situ. , 1969, The Journal of investigative dermatology.

[9]  THE REACTIONS OF THE DIGITAL ARTERY AND MINUTE PAD ARTERIES TO LOCAL COLD , 1942 .

[10]  A. B. Hertzman,et al.  THE VASOMOTOR COMPONENTS IN THE VASCULAR REACTIONS IN THE FINGER TO COLD , 1942 .

[11]  A. Ax,et al.  Photoplethysmography: system calibration and light history effects. , 1973, Psychophysiology.

[12]  A. B. Hertzman,et al.  THE ABSENCE OF VASOCONSTRICTOR REFLEXES IN THE FOREHEAD CIRCULATION. EFFECTS OF COLD , 1942 .

[13]  G. Holti The copper-tellurite-copper thermocouple adapted as a skin thermometer. , 1955, Clinical science.

[14]  R. Edelberg,et al.  Relation of electrical properties of skin to structure and physiologic state. , 1977, The Journal of investigative dermatology.

[15]  I. Swain,et al.  Non-invasive measurement of limb and digit blood flow. , 1986, Journal of biomedical engineering.

[16]  J. Weinman,et al.  A photoelectric approach to the study of peripheral circulation. , 1962, American heart journal.

[17]  J B Harness,et al.  Cross correlation between blood pressure and intracranial pressure. , 1981, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[18]  B. Sayers,et al.  Analysis of heart rate variability. , 1973, Ergonomics.

[19]  C. Ramsay,et al.  A photoelectric plethysmograph for the measurement of cutaneous blood flow. , 1974, Physics in medicine and biology.

[20]  A. C. Burton,et al.  A STUDY OF THE ADJUSTMENT OF PERIPHERAL VASCULAR TONE TO THE REQUIREMENTS OF THE REGULATION OF BODY TEMPERATURE , 1940 .

[21]  M. Stern,et al.  In vivo evaluation of microcirculation by coherent light scattering , 1975, Nature.

[22]  K. Hagbarth,et al.  Regional similarities and differences in thermoregulatory vaso‐ and sudomotor tone. , 1980, The Journal of physiology.

[23]  J. Wallace,et al.  A method for clinical evaluation of peripheral circulation: photoelectric hemodensitometry. , 1966, Surgery.

[24]  D E Strandness,et al.  Ultrasonic arteriography. A noninvasive method of arterial visualization. , 1972, Radiology.

[25]  C. Hyman,et al.  History of plethysmography. , 1961, The Journal of cardiovascular surgery.

[26]  D. J. Ellis,et al.  A theoretical and experimental study of light absorption and scattering by in vivo skin. , 1980, Physics in medicine and biology.

[27]  D. L. Halvorsen Properties and applications of piezo film transducers , 1986 .

[28]  D. A. Mcdonald Blood flow in arteries , 1974 .

[29]  M. Polanyi,et al.  In vivo studies with an intravascular and intracardiac reflection oximeter. , 1962, Journal of applied physiology.

[30]  P. Payne Measurement of skin blood flow , 1984 .

[32]  John B. Dillon,et al.  Applications of photoelectric plethysmography in peripheral vascular disease , 1940 .

[33]  A. B. Hertzman,et al.  REACTIONS OF LARGE AND SMALL ARTERIES IN MAN TO VASOCONSTRICTOR STIMULI , 1940 .

[34]  D. H. King,et al.  Arterial assessment by Doppler-shift ultrasound. , 1974, Proceedings of the Royal Society of Medicine.

[35]  G. Holloway,et al.  Laser Doppler measurement of cutaneous blood flow. , 1977, The Journal of investigative dermatology.

[36]  G. Holti,et al.  Estimation of the nutrient skin blood flow using a segmented thermal clearance probe , 1978, Clinical and experimental dermatology.

[37]  S Hocherman,et al.  Correlation between blood volume and opacity changes in the finger. , 1967, Journal of applied physiology.

[38]  M. G. Taylor,et al.  The input impedance of an assembly of randomly branching elastic tubes. , 1966, Biophysical journal.

[39]  T. Kumazawa,et al.  A PLETHYSMOGRAPHIC STUDY OF THE HUMAN SKIN UNDER VARIOUS ENVIRONMENTAL CONDITIONS. , 1964, The Japanese journal of physiology.

[40]  A. C. Burton THE RANGE AND VARIABILITY OF THE BLOOD FLOW IN THE HUMAN FINGERS AND THE VASOMOTOR REGULATION OF BODY TEMPERATURE , 1939 .

[41]  H. Barcroft,et al.  Sympathetic Control of Human Blood Vessels , 1953 .