Development of Medium-size Half-mask Facepiece for Male Workers at a Shipyard and Its Fit Performance in Korea

Ten years ago, three differently sized half-mask facepiece prototypes were constructed from silicon using computer graphics and statistical analysis to fit them according to Korean facial dimensions. The purpose of this study was to complete the medium-size half-mask respirator based on the prototype, which would provide an adequate fit performance for male workers at a shipyard, Hyundai Samho Heavy Industry Co., in Korea. The complete respirator—the hardness 55—was manufactured with existing accessories such as a filter, exhalation valve, and strap attached. The fit performance test was conducted by performing a quantitative fit-test on 48 male subjects: workers who usually wear half-mask respirators (Dobulife Tech Co., Model DM-911, Gwangju, Gyeonggi-do, Korea). The results showed that the hardness 55 provided male subject workers with much better fit performance than the existing mask constructed by the same company. Because softness of the material of the facepiece, in particular the inner part, influenced faceseal leakage, further research on developing better-fit respirator facepieces should consider carefully the fine control of material softness.

[1]  G. Rajhans,et al.  Practical Guide to Respirator Usage in Industry , 2002 .

[2]  W R Myers,et al.  Workplace protection factor measurements on powered air-purifying respirators at a secondary lead smelter: results and discussion. , 1984, American Industrial Hygiene Association journal.

[3]  D H Han,et al.  Fit factors for quarter masks and facial size categories. , 2000, The Annals of occupational hygiene.

[4]  George Wallis,et al.  WORKPLACE FIELD TESTING OF A DISPOSABLE NEGATIVE PRESSURE HALF-MASK DUST RESPIRATOR (3M 8710) , 1993 .

[5]  Vernon E. Rose,et al.  A Comparison of Respirator Fit Factors Determined by Portable Condensation Nuclei Counting and Forward Light-Scattering Photometric Methods , 1990 .

[6]  Jonathan dela Cruz,et al.  Occupational Safety and Health Administration (OSHA) , 2015 .

[7]  Bruce Bradtmiller,et al.  New Respirator Fit Test Panels Representing the Current U.S. Civilian Work Force , 2007, Journal of occupational and environmental hygiene.

[8]  Fredrik Gustafsson,et al.  Particle Filters , 2015, Encyclopedia of Systems and Control.

[9]  Lili Du,et al.  New respirator fit test panels representing the current Chinese civilian workers. , 2009, The Annals of occupational hygiene.

[10]  Cynna Selvy,et al.  Occupational Safety and Health Administration (OSHA) , 2015 .

[11]  Riedar K. Oestenstad,et al.  A Comparison of Fit Provided by Natural and Silicone Rubber Facepieces of the Same Brand of Half-Mask Respirator , 1991 .

[12]  Don-Hee Han,et al.  Development of prototypes of half-mask facepieces for Koreans using the 3D digitizing design method: a pilot study. , 2004, The Annals of occupational hygiene.