Blastocyst Microinjection Automation

Blastocyst microinjections are routinely involved in the process of creating genetically modified mice for biomedical research, but their efficiency is highly dependent on the skills of the operators. As a consequence, much time and resources are required for training microinjection personnel. This situation has been aggravated by the rapid growth of genetic research, which has increased the demand for mutant animals. Therefore, increased productivity and efficiency in this area are highly desired. Here, we pursue these goals through the automation of a previously developed teleoperated blastocyst microinjection system. This included the design of a new system setup to facilitate automation, the definition of rules for automatic microinjections, the implementation of video processing algorithms to extract feedback information from microscope images, and the creation of control algorithms for process automation. Experimentation conducted with this new system and operator assistance during the cells delivery phase demonstrated a 75% microinjection success rate. In addition, implantation of the successfully injected blastocysts resulted in a 53% birth rate and a 20% yield of chimeras. These results proved that the developed system was capable of automatic blastocyst penetration and retraction, demonstrating the success of major steps toward full process automation.

[1]  Fumihito Arai,et al.  Single cell trap on a chip using in-situ microfabrication with photo-crosslinkable resin and thermal gelation , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[2]  Byungkyu Kim,et al.  Mechanical force response of single living cells using a microrobotic system , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[3]  G. Yancopoulos,et al.  F0 generation mice fully derived from gene-targeted embryonic stem cells allowing immediate phenotypic analyses , 2007, Nature Biotechnology.

[4]  Mehdi Ammi,et al.  Realistic Visual and Haptic Rendering for Biological-Cell Injection , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[5]  Seong-Jun Choi,et al.  Handling individual mammalian embryos using microfluidics , 2001, IEEE Transactions on Biomedical Engineering.

[6]  Russell H. Taylor,et al.  Preliminary experiments in robot/human cooperative microinjection , 2003, Proceedings 2003 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat. No.03CH37453).

[7]  Edward Grant,et al.  Speeding Up Video Processing for Blastocyst Microinjection , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[8]  Bradley J. Nelson,et al.  Biological Cell Injection Using an Autonomous MicroRobotic System , 2002, Int. J. Robotics Res..

[9]  M. Capecchi,et al.  Targeted gene replacement. , 1994, Scientific American.

[10]  Edward Grant,et al.  New Developments Towards Automated Blastocyst Microinjections , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[11]  Hideaki Matsuoka,et al.  High throughput easy microinjection with a single-cell manipulation supporting robot. , 2005, Journal of biotechnology.

[12]  M. Washizu,et al.  Handling of biological cells using fluid integrated circuit , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[13]  Richard O. Duda,et al.  Use of the Hough transformation to detect lines and curves in pictures , 1972, CACM.

[14]  K.K. Tan,et al.  Computer controlled piezo micromanipulation system for biomedical applications , 2001 .

[15]  Takeo Kanade,et al.  Vision and control techniques for robotic visual tracking , 1991, Proceedings. 1991 IEEE International Conference on Robotics and Automation.

[16]  Byungkyu Kim,et al.  Cellular force measurement for force reflected biomanipulation , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[17]  Edward Grant,et al.  From teleoperated to automatic blastocyst microinjections: Designing a new system from expert-controlled operations , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[18]  Russell H. Taylor,et al.  Simple Biomanipulation Tasks with 'Steady Hand' Cooperative Manipulator , 2003, MICCAI.

[19]  Jaydev P. Desai,et al.  Evaluating the Effect of Force Feedback in Cell Injection , 2007, IEEE Transactions on Automation Science and Engineering.

[20]  Nikolai Dechev,et al.  Development of a five degree-of-freedom biomanipulator for autonomous single cell electroporation , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[21]  R Yanagimachi,et al.  Intracytoplasmic sperm injection in the mouse. , 1995, Biology of reproduction.

[22]  Wei Zhao,et al.  A micro visual servo system for biological cell manipulation: overview and new developments , 2002, 7th International Conference on Control, Automation, Robotics and Vision, 2002. ICARCV 2002..

[23]  Young-Ho Kim,et al.  An integrated bio cell processor for single embryo cell manipulation , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[24]  E. Dubois,et al.  Digital picture processing , 1985, Proceedings of the IEEE.

[25]  R. Petters,et al.  Transgenic animals as models for human disease , 2004, Transgenic Research.

[26]  Yu Sun,et al.  A Fully Automated Robotic System for Microinjection of Zebrafish Embryos , 2007, PloS one.