An improved resonant thermal converter based on micro-bridge resonator

This paper presents the design, fabrication and testing of an improved thin-film thermal converter based on an electro-thermally excited and piezo-resistively detected micro-bridge resonator. The resonant thermal converter comprises a bifilar heater and an opposing micro-bridge resonator. When the micro-bridge resonator absorbs the radiant heat from the heater, its axial strain changes, then its resonant frequency follows. Therefore the alternating voltage or current can be transferred to the equivalent DC quantity. A non-contact temperature sensing mechanism eliminates heat loss from thermopiles and reduces coupling capacitance between the temperature sensor and the heater compared with traditional thin-film thermal converters based on thermopiles. In addition, the quasi-digital output of the resonant thin-film thermal converter eliminates such problems as intensity fluctuations associated with analogue signals output by traditional thin-film thermal converters. Using the fast-reversed DC (FRDC) method, the thermoelectric transfer difference, which determines the frequency-independent part of the ac-dc transfer difference, is evaluated to be as low as 1.1 ·10−6. It indicates that the non-contact temperature sensing mechanism is a feasible method to develop a high-performance thermal converter.

[1]  Miko Elwenspoek,et al.  Micro resonant force gauges , 1992 .

[2]  Shoji Kawahito,et al.  Design of a Sub-Picosecond Jitter with Adjustable-Range CMOS Delay-Locked Loop for High-Speed and Low-Power Applications , 2016, Sensors.

[3]  M. Klonz,et al.  Accurate Thin Film Multijunction Thermal Converter on a Silicon Chip , 1988, 1988 Conference on Precision Electromagnetic Measurements.

[4]  Dependence of the Resonance Frequency of Mircobridge Resonators on the Thermal Power and Vacuum , 2012 .

[5]  M. Klonz,et al.  Development of a fast-reversed-dc current source , 1994, Proceedings of Conference on Precision Electromagnetic Measurements Digest.

[6]  J. R. Kinard,et al.  New high-frequency MJTCs of novel design on fused silica substrates , 2012, 2012 Conference on Precision electromagnetic Measurements.

[7]  J. R. Kinard,et al.  Performance of multilayer thin-film multijunction thermal converters , 1994 .

[8]  F. L. Katzmann A new isothermal multijunction differential thermal element provides fast settling AC to DC converter , 1989 .

[9]  Jung-Hee Lee,et al.  A planar Bi-Sb multijunction thermal converter with small ac-dc transfer differences , 2002, IEEE Trans. Instrum. Meas..

[10]  Héctor Laiz,et al.  Development of thin-film multijunction thermal converters at PTB/IPHT , 2001, IEEE Trans. Instrum. Meas..

[11]  Peng Zhang,et al.  A Novel Film Thermal Converter Based on an Electrothermally Excited/Piezoresistively Detected Microbridge Resonator , 2018, IEEE Transactions on Instrumentation and Measurement.

[12]  M. Klonz,et al.  Fast thin-film isothermal ac-dc converter with radiometric sensing , 1995 .

[13]  H. Fujiki,et al.  High-Performance Thin-Film Multijunction Thermal Converter Developed at AIST , 2004, 2004 Conference on Precision Electromagnetic Measurements.

[14]  E. Kessler,et al.  Low-frequency ac-dc voltage transfer standards with new high sensitivity and low power coefficient thin-film Multijunction Thermal Converters , 2002, CPEM 2002.

[15]  Manfred Klonz,et al.  Explanation for the AC–DC Voltage Transfer Differences in Thin-Film Multijunction Thermal Converters on Silicon Chips at High Frequencies , 2007, IEEE Transactions on Instrumentation and Measurement.

[16]  M. Klonz,et al.  AC-DC-mV-transfer with highly sensitive thin-film multijunction thermal converters , 1993 .

[17]  M. Klonz,et al.  Accurate thin film multijunction thermal converter on a silicon chip (AC-DC standard) , 1989 .

[18]  Manfred Klonz,et al.  AC-DC thermal converter with infrared-transmissive fiber coupling , 1999, IEEE Trans. Instrum. Meas..

[19]  F. L. Katzmann,et al.  A new optically sensed thermal element for precise AC-DC conversion , 1993 .

[20]  M. Klonz,et al.  Fast reversed dc: basic reference for ac-dc transfer , 1996, Proceedings of 20th Biennial Conference on Precision Electromagnetic Measurements.

[21]  M. Klonz,et al.  Increasing the time constant of a thin film multijunction thermal converter for low frequency application , 1991 .

[22]  Torsten Funck,et al.  New Generation of Crystal Quartz Thin-Film Multijunction Thermal Converters , 2006, IEEE Transactions on Instrumentation and Measurement.

[23]  M. Klonz,et al.  Measuring thermoelectric effects in thermal converters with a fast reversed DC , 1995 .

[24]  M. Klonz,et al.  A thin-film dual heater ac-dc converter with infrared sensor , 1994, Proceedings of Conference on Precision Electromagnetic Measurements Digest.

[25]  V. Bubanja,et al.  The ac-dc difference of single-junction thermal converters , 2000 .

[26]  M. Klonz,et al.  High-precision AC-DC transfer standards at ETL , 1993 .