A Three-Phase Frequency-Adaptive Phase-Locked Loop for Independent Single-Phase Operation

This letter proposes a phase-locked loop (PLL) able to operate as an independent single-phase PLL in the context of three-phase systems. Its key advantage is that the extracted information allows the independent control of both the active and reactive powers for each phase. The proposed PLL utilizes moving average filters and, hence, remains robust under unbalanced and highly distorted voltages. A frequency estimator is also presented and incorporated in the PLL angle detector path to make it frequency adaptive. The performance of the proposed PLL is verified experimentally and results for frequency change, phase-angle jump, and unbalanced voltage sag are reported as a confirmation of its potential.

[1]  Francisco A. S. Neves,et al.  A Method for Extracting the Fundamental-Frequency Positive-Sequence Voltage Vector Based on Simple Mathematical Transformations , 2008, IEEE Transactions on Industrial Electronics.

[2]  Tarek A. Youssef,et al.  Adaptive SRF-PLL with reconfigurable controller for Microgrid in grid-connected and stand-alone modes , 2013, 2013 IEEE Power & Energy Society General Meeting.

[3]  Masoud Karimi-Ghartemani,et al.  A novel three-phase magnitude-phase-locked loop system , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[4]  J Pou,et al.  Variable-Frequency Grid-Sequence Detector Based on a Quasi-Ideal Low-Pass Filter Stage and a Phase-Locked Loop , 2010, IEEE Transactions on Power Electronics.

[5]  S. Maestri,et al.  Variable Sampling Period Filter PLL for Distorted Three-Phase Systems , 2012, IEEE Transactions on Power Electronics.

[6]  Liang Wang,et al.  A Novel Phase-Locked Loop Based on Frequency Detector and Initial Phase Angle Detector , 2013, IEEE Transactions on Power Electronics.

[7]  Josep M. Guerrero,et al.  Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines , 2014, IEEE Transactions on Power Electronics.

[8]  Vassilios G. Agelidis,et al.  Single-stage inverter-based grid-connected photovoltaic power plant with ride-through capability over different types of grid faults , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[9]  J. Doval-Gandoy,et al.  A Generic Open-Loop Algorithm for Three-Phase Grid Voltage/Current Synchronization With Particular Reference to Phase, Frequency, and Amplitude Estimation , 2009, IEEE Transactions on Power Electronics.

[10]  A. Bakhshai,et al.  A New Phase-Locked Loop System for Three-Phase Applications , 2013, IEEE Transactions on Power Electronics.

[11]  Stephen J. Finney,et al.  Three-phase phase-lock loop for distorted utilities , 2007 .

[12]  M. Monfared,et al.  Design-Oriented Study of Advanced Synchronous Reference Frame Phase-Locked Loops , 2013, IEEE Transactions on Power Electronics.

[13]  Shengtie Wang,et al.  Design and Realization of Improved Phase Locked Loop Under Unbalanced Grid Voltage in Wind Power Systems , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[14]  R. Teodorescu,et al.  A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions , 2012, IEEE Transactions on Power Electronics.