Correlation of quantitative CT with selective alveolobronchogram and pulmonary function tests in emphysema.

BACKGROUND Emphysema diagnosed by computed tomography (CT) has been reported to be correlated with morphologic data from autopsied lungs or resected lobes. However, autopsied lungs or resected lobes are quite different from lungs in vivo. We examined the correlation between a quantitative analysis of CT and the in vivo morphologic degree of emphysema (selective alveolobronchography [SAB]) in patients with COPD. METHODS We measured the mean attenuation value (MAV) of the lung fields between -700 HU and -1,024 HU to exclude the effect of high-density structures in 21 patients with COPD. Low attenuation, greater than 2 SD below the mean value of five normal healthy subjects, was used as an index of emphysema. To quantitate the amount of emphysema, the relative area of low attenuation to the area of the entire lung field (2SD percent) was measured. The morphologic degree of emphysema was determined from the diameter of ring shadow (DR) of SAB. We also examined the relationship between CT data and pulmonary function tests. RESULTS The DR was highly correlated with the CT indexes of MAV and 2SD percent; (r = -0.894, p < 0.001, and r = 0.890, p < 0.001). Both MAV and 2SD percent were correlated with pulmonary function tests such as Dco, FEV1, and residual volume (r > 0.60). CONCLUSIONS The MAV and relative area of emphysema obtained from CT density measurements accurately assess the severity of emphysema in patients with COPD as well as SAB.

[1]  J. Best,et al.  Lung CT density correlates with measurements of airflow limitation and the diffusing capacity. , 1991, The European respiratory journal.

[2]  H Nishitani,et al.  The diagnosis of mild emphysema. Correlation of computed tomography and pathology scores. , 1990, The American review of respiratory disease.

[3]  H. Sasaki,et al.  Relation between selective alveolo-bronchograms and pulmonary function tests in patients with chronic obstructive pulmonary disease. , 2015, The American review of respiratory disease.

[4]  H Adams,et al.  An appraisal of CT pulmonary density mapping in normal subjects. , 1991, Clinical radiology.

[5]  E A Zerhouni,et al.  A standard phantom for quantitative CT analysis of pulmonary nodules. , 1983, Radiology.

[6]  E. Nikkila Letter: Serum high-density-lipoprotein and coronary heart-disease. , 1976, Lancet.

[7]  L Kreel,et al.  Pulmonary tissue attenuation with computed tomography: comparison of inspiration and expiration scans. , 1979, Journal of computer assisted tomography.

[8]  J. Best,et al.  CT measurements of lung density in life can quantitate distal airspace enlargement--an essential defining feature of human emphysema. , 1988, The American review of respiratory disease.

[9]  The radiology of emphysema. , 1983 .

[10]  J. Mead,et al.  IMPROVED TECHNIQUE FOR ESTIMATING PLEURAL PRESSURE FROM ESOPHAGEAL BALLOONS. , 1964, Journal of applied physiology.

[11]  N J Morrison,et al.  Limitations of computed tomography in the assessment of emphysema. , 1989, The American review of respiratory disease.

[12]  F D Thomas,et al.  Density patterns in the normal lung as determined by computed tomography. , 1980, Radiology.

[13]  J. Best,et al.  DIAGNOSIS OF PULMONARY EMPHYSEMA BY COMPUTERISED TOMOGRAPHY , 1984, The Lancet.

[14]  P. Paré,et al.  The diagnosis of emphysema. A computed tomographic-pathologic correlation. , 1986, The American review of respiratory disease.

[15]  V L Roggli,et al.  Centrilobular emphysema: CT-pathologic correlation. , 1986, Radiology.

[16]  R. Forster,et al.  A standardized breath holding technique for the clinical measurement of the diffusing capacity of the lung for carbon monoxide. , 1957, The Journal of clinical investigation.

[17]  P H Nath,et al.  Detection of emphysema with computed tomography. Correlation with pulmonary function tests and chest radiography. , 1988, Investigative radiology.

[18]  N. Müller,et al.  Comparison of single breath carbon monoxide diffusing capacity and pressure-volume curves in detecting emphysema. , 1990, The American review of respiratory disease.

[19]  R H Hruban,et al.  High resolution computed tomography of inflation-fixed lungs. Pathologic-radiologic correlation of centrilobular emphysema. , 1987, The American review of respiratory disease.

[20]  N J Morrison,et al.  Quantitation of emphysema by computed tomography using a "density mask" program and correlation with pulmonary function tests. , 1990, Chest.

[21]  R R Miller,et al.  CT in the qualitative assessment of emphysema , 1986, Journal of thoracic imaging.

[22]  N. Müller,et al.  "Density mask". An objective method to quantitate emphysema using computed tomography. , 1988, Chest.

[23]  H Oeser,et al.  Measurement of Lung Density by Computed Tomography , 1978, Journal of computer assisted tomography.

[24]  [Central and peripheral airways as determinants of ventilatory function in patients with chronic bronchitis, emphysema and bronchial asthma]. , 2015, Nihon Kyobu Shikkan Gakkai zasshi.

[25]  T. Takishima,et al.  Selective alveolo-bronchography in chronic pulmonary emphysema. , 1969, The Tohoku journal of experimental medicine.

[26]  G. Laszlo,et al.  Computed tomography in pulmonary emphysema. , 1982, Clinical radiology.