Static force dependency of bone conduction transducer as sensory feedback for stump-socket based prosthesis

© 2018 Australasian Robotics and Automation Association. All rights reserved. The dependency of a novel sensory feedback for stump-socket based prosthesis on the static force is presented using a bone conduction transducer as feedback source. The stimulation was induced onto the bony landmarks of the elbow, specifically the Ulna and presented in an interval halving method. The perception threshold in the range of tactile and auditory perception at three different force levels has been tested. The inter subject variability is bigger than the intra subject variation. The small static force variation suggests a similar approach as in bone conduction hearing aids and therefore a static force bigger than 6N should be applied to perceive a constant stimulation. A mechanical design to include such a novel feedback into a stump-socket needs to account for this requirement. The inter subject variability needs to be addressed by incorporate some kind of person to person calibration of the gain.

[1]  Joan E Sanders,et al.  Residual limb volume change: systematic review of measurement and management. , 2011, Journal of rehabilitation research and development.

[2]  Gursel Alici,et al.  A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands , 2018, IEEE Access.

[3]  Jacob L. Segil,et al.  Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review. , 2013, Journal of rehabilitation research and development.

[4]  J. A. Florez,et al.  Calibration of force sensing resistors (fsr) for static and dynamic applications , 2010, 2010 IEEE ANDESCON.

[5]  Joan E Sanders,et al.  Preliminary investigation of residual-limb fluid volume changes within one day. , 2012, Journal of rehabilitation research and development.

[6]  Christian Antfolk,et al.  A review of invasive and non-invasive sensory feedback in upper limb prostheses , 2017, Expert review of medical devices.

[7]  Diana Cortés,et al.  Bone Conduction Transducer: Output Force Dependency on Load Condition , 2002 .

[8]  Jacqueline S. Hebert,et al.  Applications of sensory feedback in motorized upper extremity prosthesis: a review , 2014, Expert review of medical devices.

[9]  Dario Farina,et al.  Closed-Loop Control of Myoelectric Prostheses With Electrotactile Feedback: Influence of Stimulation Artifact and Blanking , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[10]  Edith L. R. Corliss,et al.  Mechanical Impedance of the Forehead and Mastoid , 1954 .

[11]  Dario Farina,et al.  Reflections on the present and future of upper limb prostheses , 2016, Expert review of medical devices.

[12]  R. Brånemark,et al.  Osseointegrated prostheses for rehabilitation following amputation , 2017, Der Unfallchirurg.

[13]  Christian Antfolk,et al.  Sensory feedback in upper limb prosthetics , 2013, Expert review of medical devices.

[14]  Aaron M. Dollar,et al.  Performance characteristics of anthropomorphic prosthetic hands , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[15]  Praveen Badwaik,et al.  Osseoperception: An Implant Mediated Sensory Motor Control- A Review. , 2015, Journal of clinical and diagnostic research : JCDR.