Distribution of mechanical impedance at the fingers and the palm of the human hand.

A comprehensive understanding of the complex biodynamic response of the human fingers-hand-arm system may help researchers determine the causation of injuries arising from hand-transmitted vibration. This study theoretically demonstrates that the mechanical impedance (MI) in a hand power grip, as a measure of the biodynamic response of the system, can be divided into finger MI and palm MI. A methodology is developed to measure them separately and to investigate their distribution characteristics. This study involves 6 adult male subjects, constant-velocity sinusoidal excitations at 10 different discrete frequencies (16, 25, 40, 63, 100, 160, 250, 400, 630, 1000 Hz), and three different hand-handle coupling conditions. Our results suggest that at low frequencies (40 Hz), the palm MI is substantially higher than the finger MI; the majority of the hand MI remains distributed at the palm up to 100 Hz; and at frequencies higher than 160 Hz, the finger MI is comparable to or higher than the palm MI. Furthermore, at frequencies equal to or above 100 Hz, the finger MI is practically independent of the palm-handle coupling conditions. Knowledge of the MI distribution pattern may increase the understanding of vibration transmission to the hand and aid in the development of effective isolation devices.

[1]  Massimo Bovenzi,et al.  Exposure-response relationship in the hand-arm vibration syndrome: an overview of current epidemiology research , 1998, International archives of occupational and environmental health.

[2]  Steve Kihlberg,et al.  Biodynamic response of the hand-arm system to vibration from an impact hammer and a grinder , 1995 .

[3]  R. G. Dong,et al.  Dynamic Characterization of Instrumented Handle and Palm-Adapter Used for Assessment of Vibration Transmissibility of Gloves , 2003 .

[4]  L. Burström,et al.  Absorption of vibration energy in the human hand and arm. , 1994, Ergonomics.

[5]  J. Hyvärinen,et al.  Transmission of vibration in the hand-arm system with special reference to changes in compression force and acceleration. , 1976, Scandinavian journal of work, environment & health.

[6]  Michael J. Griffin,et al.  Handbook of Human Vibration , 1990 .

[7]  M. Bovenzi,et al.  Prevalence of vibration-induced white finger and assessment of vibration exposure among travertine workers in Italy , 1988, International archives of occupational and environmental health.

[8]  Ronnie Lundström,et al.  Mechanical impedance of the human hand-arm system , 1989 .

[9]  A Fiorito,et al.  Bone and joint disorders in the upper extremities of chipping and grinding operators , 1987, International archives of occupational and environmental health.

[10]  G Gemne,et al.  Bone and joint pathology in workers using hand-held vibrating tools. An overview. , 1987, Scandinavian journal of work, environment & health.

[11]  S. Geisser,et al.  On methods in the analysis of profile data , 1959 .

[12]  G. J. Gouw,et al.  A study of hand grip pressure distribution and EMG of finger flexor muscles under dynamic loads. , 1995, Ergonomics.

[13]  R. Dandanell,et al.  Vibration from riveting tools in the frequency range 6 Hz-10 MHz and Raynaud's phenomenon. , 1986, Scandinavian journal of work, environment & health.

[14]  富永 洋志夫,et al.  The relationship between vibration exposure and symptoms of vibration syndrome , 1993 .

[15]  M. J. Griffin,et al.  The transmission of vibration to the hand and the influence of gloves , 1982 .

[16]  E. N. Angevine,et al.  Hand-arm vibration, part II: Vibration transmission characteristics of the hand and arm , 1977 .

[17]  Donald E. Wasserman,et al.  Hand-Arm Vibration: A Comprehensive Guide for Occupational Health Professionals , 1992 .

[18]  M J Griffin,et al.  Haemodynamic changes in ipsilateral and contralateral fingers caused by acute exposures to hand transmitted vibration. , 1997, Occupational and environmental medicine.

[19]  M J Griffin,et al.  Effect of contact conditions on the mechanical impedance of the finger. , 1996, Central European journal of public health.

[20]  J Starck,et al.  Physical characteristics of vibration in relation to vibration-induced white finger. , 1990, American Industrial Hygiene Association journal.

[21]  A. J. Brammer,et al.  Vibration effects on the hand and arm in industry , 1984 .

[22]  Hikaru Inooka,et al.  Characteristics of human fingertips in the shearing direction , 2000, Biological Cybernetics.

[23]  Donald E. Wasserman,et al.  Energy entering the hands of operators of pneumatic tools used in chipping and grinding operations , 1982 .

[24]  L Burström,et al.  Measurements of the impedance of the hand and arm , 1990, International archives of occupational and environmental health.

[25]  Clifford Goodman,et al.  American Society of Mechanical Engineers , 1988 .

[26]  R. Lundström Local vibrations--mechanical impedance of the human hand's glabrous skin. , 1984, Journal of biomechanics.

[27]  Subhash Rakheja,et al.  a Comparison of Biodynamic Models of the Human HAND-ARM System for Applications to Hand-Held Power Tools , 2002 .

[28]  J S Cundiff Energy dissipation in human hand-arm exposed to random vibration. , 1976, The Journal of the Acoustical Society of America.

[29]  B. J. Winer Statistical Principles in Experimental Design , 1992 .

[30]  R. Howe,et al.  Identification of the mechanical impedance at the human finger tip. , 1997, Journal of biomechanical engineering.

[31]  Joseph LaDou,et al.  Occupational & environmental medicine , 1997 .