Vibration-Induced Phase Noise: It Isn't Just About the Oscillator

Very often, actual, measured levels of vibration-induced phase noise in signal generation equipment are significantly higher than predicted. In many cases, this is because the frequency sensitivity of the oscillator or oscillator resonator to vibration was assumed to be the sole source of the degradation. As improvements in oscillator output signal static phase noise and vibration sensitivity have been realized, the effects of vibration in non-oscillator components and assemblies have become more dominant and cannot be ignored. Primary contributors to vibration-induced signal phase modulation include coaxial cables and cable connectors, narrowband filters, and enclosure mechanical resonances and non-linearities. Accurate measurement of vibration-induced, signal spectral degradation is often difficult due to the influence of both the measurement environment and test apparatus. In addition, isolating and eliminating the cause of out-of-spec hardware performance is time consuming and expensive. This paper will describe potential sources of vibration-induced signal spectral degradation and methods for obtaining and verifying adequately low vibration sensitivity in non-oscillator hardware.

[1]  A VHF, quartz crystal oscillator exhibiting exceptional vibration immunity , 1996, Proceedings of 1996 IEEE International Frequency Control Symposium.

[2]  R. Filler,et al.  The acceleration sensitivity of quartz crystal oscillators: a review , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  A. Hati,et al.  Vibration-induced PM noise in oscillators and measurements of correlation with vibration sensors , 2005, Proceedings of the 2005 IEEE International Frequency Control Symposium and Exposition, 2005..

[4]  R. D. Weglein The vibration-induced phase noise of a visco-elastically supported crystal resonator , 1989, Proceedings of the 43rd Annual Symposium on Frequency Control.

[5]  Vincent R. Rosati,et al.  Reduction of the Effects of Vibration on SC-Cut Quartz Crystal Oscillators , 1981 .

[6]  M. Mossammaparast,et al.  3-axis vibration performance of a compact sapphire microwave oscillator , 2001, Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218).

[7]  P. Renoult,et al.  Improved oscillator phase noise characteristic under harsh environmental conditions by use of mechanical filters , 1999, Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313).