Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement.

A multicenter retrospective review was performed analyzing 1081 primary total hip replacements in 944 patients using the Harris Galante-I cementless acetabular component with screw fixation. All patients were followed up for a minimum of 5 years with a mean followup of 81 months. Linear polyethylene wear averaged 0.11 mm/year (range, 0-0.86 mm/year). Pelvic osteolysis was seen in 25 patients (2.3%). Migration of the acetabular component was seen in four hips. A subgroup of patients was reanalyzed at a minimum followup of 10 years. The mean linear polyethylene wear rate remained 0.11 mm/year. In this group, only one socket had migrated. There was an association between wear rate and age. On average, younger patients had higher wear rates. The risk for having pelvic osteolysis develop and the need for revision surgery also was age-related. Twenty-two percent of hip replacements (15 hips) in patients younger than 50 years of age at the time of their index operation had pelvic osteolysis develop. In contrast, for patients older than 50 years of age at the time of surgery only 7.8% (eight hips) had osteolysis of the pelvis develop. For patients older than 70 years of age at the time of primary total hip replacement, none had pelvic osteolysis develop.

[1]  W. Harris,et al.  In Vivo Skeletal Responses to Porous-Surfaced Implants Subjected to Small Induced Motions* , 1997, The Journal of bone and joint surgery. American volume.

[2]  B. Morrey,et al.  Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.

[3]  M Jasty,et al.  Histological and radiographic assessment of well functioning porous-coated acetabular components. A human postmortem retrieval study. , 1993, The Journal of bone and joint surgery. American volume.

[4]  George A. Zarb,et al.  Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry , 1985 .

[5]  T P Schmalzried,et al.  Quantitative Assessment of Walking Activity after Total Hip or Knee Replacement* , 1998, The Journal of bone and joint surgery. American volume.

[6]  C. Engh,et al.  Treatment of Pelvic Osteolysis Associated with a Stable Acetabular Component Inserted without Cement as Part of a Total Hip Replacement* , 1997, The Journal of bone and joint surgery. American volume.

[7]  C. Engh,et al.  Long-Term Results of Use of the Anatomic Medullary Locking Prosthesis in Total Hip Arthroplasty* , 1997, The Journal of bone and joint surgery. American volume.

[8]  K E Marks,et al.  A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. , 1982, The Journal of bone and joint surgery. American volume.

[9]  C. Engh,et al.  Patterns of osteolysis around total hip components inserted with and without cement. , 1995, The Journal of bone and joint surgery. American volume.

[10]  A. Malcolm,et al.  The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. , 1992, Clinical orthopaedics and related research.

[11]  P. Saluan,et al.  The Porous-Coated Anatomic Total Hip Prosthesis: Failure of the Metal-Backed Acetabular Component* , 1996, The Journal of bone and joint surgery. American volume.

[12]  J. Charnley,et al.  Socket wear in Charnley low friction arthroplasty of the hip. , 1978, Clinical orthopaedics and related research.

[13]  R. N. Stauffer,et al.  Cemented total hip arthroplasty with contemporary techniques. A five-year minimum follow-up study. , 1988, Clinical orthopaedics and related research.

[14]  J. Galante,et al.  Total hip replacement with insertion of an acetabular component without cement and a femoral component with cement. Four to seven-year results. , 1995, The Journal of bone and joint surgery. American volume.

[15]  M. Porter,et al.  The Long-Term Results of Charnley Low-Friction Arthroplasty in Young Patients Who Have Congenital Dislocation, Degenerative Osteoarthrosis, or Rheumatoid Arthritis* , 1997, The Journal of bone and joint surgery. American volume.

[16]  R. Hall Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. , 1998, The Journal of bone and joint surgery. American volume.

[17]  C. Colwell,et al.  The femoral component in total hip arthroplasty. Six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique. , 1994, The Journal of bone and joint surgery. American volume.

[18]  W. Maloney,et al.  A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component. , 1994, The Journal of arthroplasty.

[19]  J. Galante,et al.  Histology of porous-coated acetabular components. 25 cementless cups retrieved after arthroplasty. , 1993, Acta orthopaedica Scandinavica.

[20]  W H Harris,et al.  The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review. , 1990, The Journal of bone and joint surgery. British volume.

[21]  D. McMahon,et al.  Osteolysis after Charnley primary low-friction arthroplasty. A comparison of two matched paired groups. , 1998, The Journal of bone and joint surgery. British volume.