The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long-term review.

BACKGROUND A long-term review of metal prosthetic radial head replacement in patients with radial head fractures associated with gross instability of the elbow has been performed. METHOD Twenty patients were reviewed using a modified Mayo Clinic functional rating index system. The mean follow-up was 12.1 years, with a range from 6 to 29 years. RESULTS Results were excellent in 12 patients, good in 4 patients, fair in 2 patients, and poor in 2 patients. A metal radial head replacement restored elbow stability when fracture of the radial head occurred in combination with dislocation of the elbow, rupture of the medial collateral ligament, fracture of the proximal ulna, and/or fracture of the coronoid process. CONCLUSION We conclude that a metal radial head prosthesis has select indications. We advocate its use when the radial head cannot be reconstructed in the setting of a clinically unstable elbow. Results suggest that it functions well on a long-term basis.

[1]  L. Riley,et al.  Ectopic ossification following total hip replacement. Incidence and a method of classification. , 1973, The Journal of bone and joint surgery. American volume.

[2]  E. Chao,et al.  Biomechanical study of the elbow following excision of the radial head. , 1979, The Journal of bone and joint surgery. American volume.

[3]  I. Harrington,et al.  Replacement of the radial head in the treatment of unstable elbow fractures. , 1981, Injury.

[4]  J. Medige,et al.  Silicone rubber replacement of the severely fractured radial head. , 1986, Clinical orthopaedics and related research.

[5]  Fracture of silastic radial-head prosthesis. Case report. , 1981, The Journal of bone and joint surgery. American volume.

[6]  M. Mason Some observations on fractures of the head of the radius with a review of one hundred cases , 1954, The British journal of surgery.

[7]  P. Piriou,et al.  A floating prosthesis for radial-head fractures. , 1996, The Journal of bone and joint surgery. British volume.

[8]  G. Edwards,et al.  Radial head prosthesis in the management of radial head fractures. , 1960, Canadian journal of surgery. Journal canadien de chirurgie.

[9]  A A Amis,et al.  Primary replacement of the fractured radial head with a metal prosthesis. , 1993, The Journal of bone and joint surgery. British volume.

[10]  A. Alexander,et al.  Mason Type II Radial Head Fractures: Operative Versus Nonoperative Treatment , 1992, Journal of orthopaedic trauma.

[11]  R. A. Mcarthur Herbert screw fixation of fracture of the head of the radius. , 1987, Clinical orthopaedics and related research.

[12]  J. Kellam,et al.  Open Reduction and Internal Fixation of Radial Head Fractures , 1991, Journal of orthopaedic trauma.

[13]  B. Morrey,et al.  Results of delayed excision of the radial head after fracture. , 1986, The Journal of bone and joint surgery. American volume.

[14]  B. Kristiansen,et al.  Evaluation of instruments for measuring grip strength. , 1984, Acta orthopaedica Scandinavica.

[15]  E. Chao,et al.  Silastic prosthetic replacement for the radial head. , 1981, The Journal of bone and joint surgery. American volume.