Quadriceps force after TKA with femoral single radius

Background and purpose New implant designs have incorporated a single radius instead of a multiple radius to the femoral component in order to improve the mechanical function after TKA. We investigated the amount of quadriceps force required to extend the knee during an isokinetic extension cycle of different total knee designs, focusing on the radius of the femoral component (single vs. multiple). Methods Human knee specimens (n = 12, median patient age 68 (63–70) years) were tested in a kinematic knee-simulating machine untreated and after implantation of 2 types of knee prosthesis systems, one with a single femoral radius design and one with a multiple femoral radius design. During the test cycle, a hydraulic cylinder, which simulated the quadriceps muscle, applied sufficient force to the quadriceps tendon to produce a constant extension moment of 31 Nm. The quadriceps extension force was measured from 120° to full knee extension. Results The shape of the quadriceps force curve was typically sinusoidal before and after TKA, reaching a maximum value of 1,493 N at 110°. With the single femoral radius design, quadriceps force was similar to that of the normal knee: 1,509 N at 110° flexion (p = 0.4). In contrast, the multiple femoral radius design showed an increase in quadriceps extension force relative to the normal knee, with a maximum of 1,721 N at 90° flexion (p = 0.03). Interpretation The single femoral radius design showed lower maximum extension forces than the multiple femoral radius design. In addition, with the single femoral radius design maximum quadriceps force needed to extend a constant extension force shifted to higher degrees of knee flexion, representing a more physiological quadriceps force pattern, which could have a positive effect on knee function after TKA.

[1]  D A Dennis,et al.  In Vivo Anteroposterior Femorotibial Translation of Total Knee Arthroplasty: A Multicenter Analysis , 1998, Clinical orthopaedics and related research.

[2]  M J Askew,et al.  Kinematics of posterior cruciate ligament-retaining and -sacrificing mobile bearing total knee arthroplasties. An in vitro comparison of the New Jersey LCS meniscal bearing and rotating platform prostheses. , 1997, The Journal of arthroplasty.

[3]  Quadriceps force during knee extension after non-hinged and hinged TKA: An in vitro study , 2008, Acta orthopaedica.

[4]  Christof Hurschler,et al.  Quadriceps force in relation of intrinsic anteroposterior stability of TKA design , 2009, Archives of Orthopaedic and Trauma Surgery.

[5]  C. Hurschler,et al.  In vitro investigation of the influence of tibial slope on quadriceps extension force after total knee arthroplasty , 2006, Knee Surgery, Sports Traumatology, Arthroscopy.

[6]  T. Andriacchi,et al.  The influence of total knee-replacement design on walking and stair-climbing. , 1982, The Journal of bone and joint surgery. American volume.

[7]  S. Banks,et al.  Sagittal curvature of total knee replacements predicts in vivo kinematics. , 2007, Clinical biomechanics.

[8]  T P Andriacchi,et al.  Biomechanics and gait analysis in total knee replacement. , 1988, Orthopaedic review.

[9]  A. T. Berman,et al.  Evaluation of total knee arthroplasty using isokinetic testing. , 1991, Clinical orthopaedics and related research.

[10]  Darryl D D'Lima,et al.  Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm. , 2005, The Knee.

[11]  K R Kaufman,et al.  The effect of trochlear design on patellofemoral shear and compressive forces in total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[12]  D. Rosenbaum,et al.  Clinical and functional comparison of bicondylar sledge prostheses retaining all ligaments and constrained total knee replacement. , 2004, Clinical biomechanics.

[13]  C Hurschler,et al.  Quadriceps function after TKA--an in vitro study in a knee kinematic simulator. , 2004, Clinical biomechanics.

[14]  J Perry,et al.  Functional comparison of posterior cruciate-retained versus cruciate-sacrificed total knee arthroplasty. , 1988, Clinical orthopaedics and related research.

[15]  R. Nisell,et al.  Mechanics of the knee. A study of joint and muscle load with clinical applications. , 1985, Acta orthopaedica Scandinavica. Supplementum.

[16]  C J Wirth,et al.  Relative motion of a mobile bearing inlay after total knee arthroplasty--dynamic in vitro study. , 2002, Clinical biomechanics.

[17]  Paul G. J. Maquet Mechanics of the Knee , 1976 .