Influence of mesh density, cortical thickness and material properties on human rib fracture prediction.

The purpose of this paper was to investigate the sensitivity of the structural responses and bone fractures of the ribs to mesh density, cortical thickness, and material properties so as to provide guidelines for the development of finite element (FE) thorax models used in impact biomechanics. Subject-specific FE models of the second, fourth, sixth and tenth ribs were developed to reproduce dynamic failure experiments. Sensitivity studies were then conducted to quantify the effects of variations in mesh density, cortical thickness, and material parameters on the model-predicted reaction force-displacement relationship, cortical strains, and bone fracture locations for all four ribs. Overall, it was demonstrated that rib FE models consisting of 2000-3000 trabecular hexahedral elements (weighted element length 2-3mm) and associated quadrilateral cortical shell elements with variable thickness more closely predicted the rib structural responses and bone fracture force-failure displacement relationships observed in the experiments (except the fracture locations), compared to models with constant cortical thickness. Further increases in mesh density increased computational cost but did not markedly improve model predictions. A ±30% change in the major material parameters of cortical bone lead to a -16.7 to 33.3% change in fracture displacement and -22.5 to +19.1% change in the fracture force. The results in this study suggest that human rib structural responses can be modeled in an accurate and computationally efficient way using (a) a coarse mesh of 2000-3000 solid elements, (b) cortical shells elements with variable thickness distribution and (c) a rate-dependent elastic-plastic material model.

[1]  Stanislaw P Stawicki,et al.  Trauma. 5th ed , 2004 .

[2]  Masami Iwamoto,et al.  Effect of assumed stiffness and mass density on the impact response of the human chest using a three-dimensional FE model of the human body. , 2006, Journal of biomechanical engineering.

[3]  J. Melvin,et al.  Accidental Injury: Biomechanics and Prevention , 1993 .

[4]  J. Currey,et al.  Strain rate and mineral content in fracture models of bone , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  J. Crandall,et al.  Rib fractures under anterior-posterior dynamic loads: experimental and finite-element study. , 2010, Journal of biomechanics.

[6]  King H. Yang,et al.  Development of a Three-Dimensional Finite Element Chest Model for the 5(th) Percentile Female. , 2005, Stapp car crash journal.

[7]  S. Robin,et al.  HUMOS: HUMAN MODEL FOR SAFETY - A JOINT EFFORT TOWARDS THE DEVELOPMENT OF REFINED HUMAN-LIKE CAR OCCUPANT MODELS , 2001 .

[8]  Karl Schweizerhof,et al.  FE Human Modelling in Crash - Aspects of the numerical Modelling and current Applications in the Automotive Industry , 2007 .

[9]  Atsutaka Tamura,et al.  Elderly Human Thoracic FE Model Development and Validation , 2005 .

[10]  Benoît Besnault,et al.  DEVELOPMENT OF A 3D FINITE ELEMENT MODEL OF THE HUMAN BODY , 1998 .

[11]  E. Hoffman,et al.  Geometry and kinematics of dog ribs. , 1989, Journal of applied physiology.

[12]  Yasuhiro Dokko,et al.  Development of Adult and Elderly FE Thorax Skeletal Models , 2009 .

[13]  Laura J. Freeman,et al.  The biomechanics of human ribs: material and structural properties from dynamic tension and bending tests. , 2007, Stapp car crash journal.

[14]  Pascal Baudrit,et al.  COMPARATIVE STUDIES OF DUMMY AND HUMAN BODY MODELS BEHAVIOR IN FRONTAL AND LATERAL IMPACT CONDITIONS , 1999 .

[15]  Marcus Mohr,et al.  Geometry of human ribs pertinent to orthopedic chest-wall reconstruction. , 2007, Journal of biomechanics.

[16]  Weixin Shen,et al.  Biomechanically based criteria for rib fractures induced by high-speed impact. , 2005, The Journal of trauma.

[17]  Nicole M. Grosland,et al.  IA-FEMesh: An open-source, interactive, multiblock approach to anatomic finite element model development , 2009, Comput. Methods Programs Biomed..

[18]  Xavier Trosseille,et al.  Evaluation of thoracic deflection as an injury criterion for side impact using a finite elements thorax model. , 2009, Stapp car crash journal.

[19]  Gopal Narwani,et al.  Development of a Human Body Finite Element Model for Restraint System R&D Applications , 2005 .

[20]  E. E. Ward,et al.  Modeling the effect of non-penetrating ballistic impact as a means of detecting behind armor blunt trauma. , 2005, The Journal of trauma.

[21]  Feng Luan,et al.  DEVELOPMENT OF A FINITE ELEMENT MODEL OF THE HUMAN NECK , 1998 .

[22]  Li Chai,et al.  Prediction and analysis of human thoracic impact responses and injuries in cadaver impacts using a full human body finite element model. , 2003, Stapp car crash journal.

[23]  Sonia Duprey,et al.  A Parametric Study of Hard Tissue Injury Prediction Using Finite Elements: Consideration of Geometric Complexity, Subfailure Material Properties, CT-Thresholding, and Element Characteristics , 2010, Traffic injury prevention.

[24]  Weixin Shen,et al.  Finite element models of rib as an inhomogeneous beam structure under high-speed impacts. , 2007, Medical engineering & physics.

[25]  R. Kent,et al.  A parametric study of hard tissue injury prediction using finite elements: consideration of geometric complexity, failure theory, sub-failure material properties, thresholding, and element characteristics , 2008 .

[26]  Masami Iwamoto,et al.  Development of a Three-Dimensional Finite Element Chest Model for the 5(th) Percentile Female. , 2005, Stapp car crash journal.

[27]  Kurosh Darvish,et al.  Structural and material changes in the aging thorax and their role in crash protection for older occupants. , 2005, Stapp car crash journal.

[28]  Murat Buyuk,et al.  Development of a High Strain-Rate Dependent Vehicle Model , 2005 .

[29]  L. Yamamoto,et al.  Thoracic trauma: the deadly dozen. , 2005, Critical care nursing quarterly.

[30]  Gordon R. Plank,et al.  ANALYTICAL INVESTIGATION OF DRIVER THORACIC RESPONSE TO OUT OF POSITION AIRBAG DEPLOYMENT , 1998 .

[31]  W. Kalender,et al.  Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters. , 1999, Physics in medicine and biology.

[32]  J. Weiss,et al.  Subject-specific finite element model of the pelvis: development, validation and sensitivity studies. , 2005, Journal of biomechanical engineering.

[33]  C N Mock,et al.  Rib fractures in the elderly. , 2000, The Journal of trauma.

[34]  John W. Melvin,et al.  AGE EFFECTS ON THORACIC INJURY TOLERANCE , 1996 .

[35]  John M. Cavanaugh,et al.  The Biomechanics of Thoracic Trauma , 1993 .

[36]  Masami Iwamoto,et al.  DEVELOPMENT OF A FINITE ELEMENT MODEL OF THE TOTAL HUMAN MODEL FOR SAFETY (THUMS) AND APPLICATION TO INJURY RECONSTRUCTION , 2002 .

[37]  Mickey L. Parsons,et al.  Critical Care Nursing Quarterly: Foreword , 2009 .

[38]  Xavier Trosseille,et al.  Characterization of PMHS Ribs: A New Test Methodology. , 2005, Stapp car crash journal.