Water and surface contamination monitoring using deep UV laser induced native fluorescence and Raman spectroscopy

Reagentless water and surface sensors employing laser induced native fluorescence (LINF) and resonance Raman spectroscopy (RRS) in the deep UV are making significant progress in detecting chemical and biological targets and differentiating them against a wide range of background materials. Methods for optimizing sensor performance for specific target and backgrounds materials will be discussed in relationship to closed industrial environments and open natural environments. Limits of detection and chemical specificity will be discussed for high and low spectral resolution systems for a wide range of compounds and composite particles such as spores and cells. Detection and identification of single spores at working distance of several meters is illustrated. A range of sensors will be described along with their physical and performance specifications including sample, sipper and immersion sensors for water and fixed point and scanner systems for surfaces. In addition, the use of UV LINF and RRS for detection in capillary electrophoresis and liquid chromatography will be described with limits of detection in the range of a few nmol L-1.

[1]  Ramasamy Manoharan,et al.  UV Resonance Raman Studies of Bacteria , 1992 .

[2]  William F. Hug,et al.  Status of miniature integrated UV resonance fluorescence and Raman sensors for detection and identification of biochemical warfare agents , 2005, SPIE Optics East.

[3]  Anne B. Myers,et al.  Absolute Raman cross sections for cyclohexane, acetonitrile, and water in the far-ultraviolet region , 1990 .

[4]  J. Sweedler,et al.  A multichannel native fluorescence detection system for capillary electrophoretic analysis of neurotransmitters in single neurons , 2006, Analytical and bioanalytical chemistry.

[5]  D. Relman Detection and identification of previously unrecognized microbial pathogens. , 1998, Emerging infectious diseases.

[6]  S. Asher,et al.  Raman spectroscopy of a coal liquid shows that fluorescence interference is minimized with ultraviolet excitation. , 1984, Science.

[7]  M. Starr,et al.  Sequential principal components analysis, a tool for cluster detection in large bacteriophage-typing data samples , 2005, Current Microbiology.

[8]  K. H. Fung,et al.  Stand-off Detection of Chemicals by UV Raman Spectroscopy , 2000 .

[9]  Steven D. Christesen,et al.  UV Raman spectra and cross sections of chemical agents , 2006, SPIE Defense + Commercial Sensing.

[10]  D. Huxley UV RAMAN SPECTROSCOPY , 1999 .

[11]  William F. Hug,et al.  New 224 nm Hollow Cathode Laser-UV Raman Spectrometer , 2001 .

[12]  R. Bhartia,et al.  Biochemical detection and identification false alarm rate dependence on wavelength using laser induced native fluorescence , 2006, SPIE Defense + Commercial Sensing.