Intracranial pressure waveform analysis: computation of pressure transmission and waveform shape indicators.

We studied transmission of arterial blood pressure to intracranial pressure by observing how the two pressure waveforms varied from baseline conditions to after postural change or jugular compression. Such experiments may lead to pressure waveform-based estimates of intracranial compliance. Using a single database of arterial blood pressure, central venous pressure, and intracranial pressure waveforms collected during baseline, jugular compresison, and head-elevated conditions from six Yucatan minipigs, we computed several numerical indicators of waveform shape to find an estimator of intracranial compliance. Of these indicators, two were based on the Fourier-decomposition of all three waveforms, and one was based on a new method for approximating the systolic slope of the intracranial pressure waveform. We computed amplitude transfer functions for the first six harmonics of the Fourier spectrum, treating intracranial pressure as system output and independently treating arterial blood pressure and central venous pressure as system inputs. Using these same inputs and outputs, we computed a single quotient based on the Fourier coefficients of the first six harmonics of the input and output waveforms. Finally, applying a Gaussian high-pass filter, we computed systolic slope approximations for all intracranial pressure wave cycles contained in a single respiratory cycle. Our third indicator was the mean-normalized variation of the slope approximations over a respiratory cycle. We studied how each composite at baseline varied with baseline mean intracranial pressure and how each composite changed from baseline as a result of a physical manipulation. Our analysis suggests that the composite based on respiratory variation of systolic slope approximations was positively correlated with mean intracranial pressure during baseline. The quotient based on Fourier coefficients with arterial blood pressure input seemed to increase from baseline to jugular compression. Composites that treated central venous pressure as input were both less correlated with mean intracranial pressure during baseline and exhibited less predictable changes from baseline to a physical manipulation than their counterparts that used arterial blood pressure as input. However, none of these apparent trends was statistically significant. The lack of statistically significant results may be due to the nature of the composites and/or the small sample size (n = 6). However, we hope this study stimulates further investigation of both central venous pressure-to-intracranial pressure (in addition to arterial blood pressure-to-intracranial pressure) transfer and automated computation of intracranial pressure waveform systolic slope. Such research may lead to noninvasively determined estimators of intracranial compliance.

[1]  H. Portnoy,et al.  Intracranial compliance is time-dependent. , 1987, Neurosurgery.

[2]  F. Sklar,et al.  The pressure-volume function of brain elasticity. Physiological considerations and clinical applications. , 1977, Journal of neurosurgery.

[3]  J. Löfgren,et al.  CRANIAL AND SPINAL COMPONENTS OF THE CEREBROSPINAL FLUID PRESSURE‐VOLUME CURVE , 1973, Acta neurologica Scandinavica.

[4]  C. Aine,et al.  Diagnosis of hydrocephalus by CSF pulse-wave analysis: a clinical study. , 1981, Surgical neurology.

[5]  J P Blanks,et al.  CSF pulsatility in hydrocephalus: respiratory effect on pulse wave slope as an indicator of intracranial compliance. , 1990, Neurological research.

[6]  J. Miller,et al.  Changes in the cerebrospinal fluid pulse wave spectrum associated with raised intracranial pressure. , 1987, Neurosurgery.

[7]  H. Portnoy,et al.  Systems analysis of intracranial pressure. Comparison with volume-pressure test and CSF-pulse amplitude analysis. , 1980, Journal of neurosurgery.

[8]  Miller Jd Volume and pressure in the craniospinal axis. , 1975 .

[9]  J Ekstedt,et al.  Volume/pressure relationship of the cerebrospinal space in humans. , 1983, Neurosurgery.

[10]  J. D. Burton,et al.  The physics of the cranial cavity, hydrocephalus and normal pressure hydrocephalus: mechanical interpretation and mathematical model. , 1976, Surgical neurology.

[11]  S. Galbraith,et al.  Analysis of the cerebrospinal fluid pulse wave in intracranial pressure. , 1983, Journal of neurosurgery.

[12]  J. Szewczykowski,et al.  A fast method of estimating the elastance of the intracranial system. , 1977, Journal of neurosurgery.

[13]  A. Marmarou,et al.  A nonlinear analysis of the cerebrospinal fluid system and intracranial pressure dynamics. , 1978, Journal of neurosurgery.

[14]  D. Wyper,et al.  Cerebrospinal fluid pulse pressure and intracranial volume-pressure relationships. , 1979, Journal of neurology, neurosurgery, and psychiatry.

[15]  Z L Gokaslan,et al.  Clinical experience with a continuous monitor of intracranial compliance. , 1989, Journal of neurosurgery.

[16]  I. Piper,et al.  An experimental study of cerebrovascular resistance, pressure transmission, and craniospinal compliance. , 1993, Neurosurgery.

[17]  P. Barie,et al.  Traumatic brain injury, hemorrhagic shock, and fluid resuscitation: effects on intracranial pressure and brain compliance. , 1993, Journal of neurosurgery.

[18]  R. Fishman Cerebrospinal Fluid in Diseases of the Nervous System , 1992 .

[19]  Miller,et al.  Systems analysis of cerebrovascular pressure transmission: an observational study in head-injured patients. , 1990, Journal of neurosurgery.